BS EN 60947-3 : 2009
Current
The latest, up-to-date edition.
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS
Hardcopy , PDF
English
01-01-2012
1 General
2 Terms, definitions and index of terms
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (normative) - Equipment for direct switching
of a single motor
Annex B (informative) - Items subject to agreement between
manufacturer and user
Annex C (normative) - Single pole operaated three pole
switches
Annex D (normative) - Switches, disconnectors, switch-
disconnectors and fuse-combination units for use
in photovoltaic (PV) d.c. applications
Bibliography
Annex ZA (normative) - Normative references to
international publications with their corresponding
European publications
Annex ZZ (informative) - Coverage of Essential
Requirements of EC Directives
Pertains to switches, disconnectors, switch-disconnectors and fuse-combination units to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1000 V a.c. or 1500 V d.c.
Committee |
PEL/121/1
|
DevelopmentNote |
Supersedes BS 5419(1977), 97/207425 DC and 97/207762 DC. (04/2002) Supersedes 03/100589 DC. (10/2006) To be read in conjunction with BS EN 60947-1. (07/2009) 2009 Edition remains current. Supersedes 09/30210618 DC. (05/2012) 2009 Edition Re-Issued in December 2015 & incorporates AMD 2 2015. Supersedes 13/30280680 DC. (12/2015)
|
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 60947-3:2009 | Identical |
NF EN 60947-3 : 2009 AMD 2 2015 | Identical |
I.S. EN 60947-3:2009 | Identical |
DIN EN 60947-3 : 2017 | Identical |
EN 60947-3:2009/A2:2015 | Identical |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Identical |
SN EN 60947-3 : 1999 AMD 1 2001 | Identical |
NBN EN 60947-3 : 2009 AMD 1 2012 | Identical |
BS 6037-1:2017 | Planning, design, installation and use of permanently installed access equipment. Code of practice Suspended access equipment |
17/30342093 DC : 0 | BS 6037-1 - PLANNING, DESIGN, INSTALLATION AND USE OF PERMANENTLY INSTALLED ACCESS EQUIPMENT - CODE OF PRACTICE - PART 1: SUSPENDED ACCESS EQUIPMENT |
BS 4363(1998) : 1998 | SPECIFICATION FOR DISTRIBUTION ASSEMBLIES FOR REDUCED LOW VOLTAGE ELECTRICITY SUPPLIES FOR CONSTRUCTION AND BUILDING SITES |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 6037-1:2003 | Code of practice for the planning, design, installation and use of permanently installed access equipment Suspended access equipment |
04/30092680 DC : DRAFT MAR 2004 | BS 6037-2 - CODE OF PRACTICE FOR THE PLANNING, DESIGN, INSTALLATION AND USE OF PERMANENTLY INSTALLED ACCESS EQUIPMENT - PART 2: TRAVELLING LADDERS AND GANTRIES |
93/210506 DC : DRAFT AUG 1993 | EN 50156 ELECTRICAL EQUIPMENT FOR FURNACES - PART 1 RULES FOR INSTALLATION (PREN 50156-1) |
BS 7375:1996 | Code of practice for distribution of electricity on construction and building sites |
BS 7375:2010 | Distribution of electricity on construction and demolition sites. Code of practice |
13/30283398 DC : 0 | BS 7656+A1 - SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 315 ARATING |
14/30270861 DC : 0 | BS 4163 - HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN EDUCATIONAL AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE |
BS 7656(1993) : 1993 | SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 400 A RATING |
BS 5266-4:1999 | Emergency lighting Code of practice for design, installation, maintenance and use of optical fibre systems |
BS 5502-25:1991 | Buildings and structures for agriculture Code of practice for design and installation of services and facilities |
09/30205684 DC : 0 | BS 7375 - CODE OF PRACTICE FOR DISTRIBUTION OF ELECTRICITY ON CONSTRUCTION AND BUILDING SITES |
13/30275065 DC : 0 | BS 4363+A1 - SPECIFICATION FOR DISTRIBUTION ASSEMBLIES FOR REDUCED LOW VOLTAGE ELECTRICITY SUPPLIES FOR CONSTRUCTION AND BUILDING SITES |
BS 6037-2:2004 | Code of practice for the planning, design, installation and use of permanently installed access equipment Travelling ladders and gantries |
BS 5126-1:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for direct-on-line motor starters |
BS 5126-2:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for circuit breaker units |
BS 5126-4:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for air-cooled transformers to power drilling machines |
BS 5126-3:1993 | Mining type flameproof supply and control units for use on systems up to 1100 V Specification for air-cooled lighting transformer units |
BS 5655-6:2002 | Lifts and service lifts Code of practice for the selection and installation of new lifts |
BS 5655-6:2011 | Lifts and service lifts Code of practice for the selection, installation and location of new lifts |
11/30229088 DC : 0 | BS 5655-6 - LIFTS AND SERVICE LIFTS - PART 6: CODE OF PRACTICE FOR THE SELECTION AND INSTALLATION OF NEW LIFTS |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 4163:2007 | HEALTH AND SAFETY FOR DESIGN AND TECHNOLOGY IN SCHOOLS AND SIMILAR ESTABLISHMENTS - CODE OF PRACTICE |
BS 4163:2014 | Health and safety for design and technology in educational and similar establishments. Code of practice |
IEC 60364-7-712:2017 | Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
IEC 60947-4-1:2009+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60947-5-1 : 4.0 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
IEC 61000-4-6 : 4.0 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
IEC TR 60664-2-1:2011 | Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.