Nuclear power plants. Control rooms. Supplementary control room for reactor shutdown without access to the main control room
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-09-2016

This International Standard establishes requirements for the Supplementary Control Room provided to enable the operating staff of nuclear power plants to shut down the reactor, where previously operating, and maintain the plant in a safe shut-down state in the event that control of the safety functions can no longer be exercised from the Main Control Room, due to unavailability of the Main Control Room or its facilities. The design has to ensure that the Supplementary Control Room is protected against the hazards, including any localised extreme hazards, leading to the unavailability of the Main Control Room. The standard also establishes requirements for the selection of functions, the design and organisation of the human-machine interface, and the procedures which shall be used systematically to verify and validate the functional design of the supplementary control room. It is assumed that supplementary control room provided for shutdown operations from outside the main control room would be unattended during normal plant conditions other than for periodic testing. The requirements reflect the application of human engineering principles as they apply to the human-machine interface during such periodic testing and during abnormal plant conditions. This standard does not cover special emergency response facilities (e.g. a technical support centre) or facilities provided for radioactive waste handling. Detailed equipment design is also outside the scope of the standard. This standard follows the principles of IAEA Specific Safety Requirements SSR-2/1 and IAEA Safety GuideNS-G-1.3. The purpose of this standard is to provide functional design requirements to be used in the design of the supplementary control room of a nuclear power plant to meet safety requirements. This standard is intended for application to a supplementary control room whose conceptual design is initiated after the publication of this standard. If it is desired to apply it to existing plants or designs, special care must be taken to ensure a consistent design basis. This relates, for example, to factors such as the consistency between the supplementary control room and the main control room, the ergonomic approach, the automation level and the information technology, and the extent of modifications to be implemented in I&C systems.

Committee
NCE/8
DevelopmentNote
Supersedes 08/30166255 DC. Renumbers and Supersedes BS IEC 60965. 2011 version incorporates corrigendum to BS IEC 60965. (09/2011) Supersedes 15/30298379 DC. (09/2016)
DocumentType
Standard
Pages
28
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
IEC 60947-4-1:2009 Identical
EN 60965:2016 Identical
IEC 60965:2016 Identical

EN 60964:2010 Nuclear power plants - Control rooms - Design
IEC 61226:2009 Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions
EN ISO 11064-6:2005 Ergonomic design of control centres - Part 6: Environmental requirements for control centres (ISO 11064-6:2005)
IEC 61839:2000 Nuclear power plants - Design of control rooms - Functional analysis and assignment
IEC 62138:2004 Nuclear power plants - Instrumentation and control important for safety - Software aspects for computer-based systems performing category B or C functions
IEC 60980:1989 Recommended practices for seismic qualification of electrical equipment of the safety system for nuclear generating stations
IEC 61508-4:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508)
IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
EN 61226:2010 Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions
IEC 61227:2008 Nuclear power plants - Control rooms - Operator controls
ISO 11064-6:2005 Ergonomic design of control centres Part 6: Environmental requirements for control centres
IEC 61771:1995 Nuclear power plants - Main control-room - Verification and validation of design
IEC 60880:2006 Nuclear power plants - Instrumentation and control systems important to safety - Software aspects for computer-based systems performing category A functions
IEC 60780:1998 Nuclear power plants - Electrical equipment of the safety system - Qualification
ISO 11064-3:1999 Ergonomic design of control centres — Part 3: Control room layout
ISO 11064-1:2000 Ergonomic design of control centres Part 1: Principles for the design of control centres
IEC 61513:2011 Nuclear power plants - Instrumentation and control important to safety - General requirements for systems
IEC 60709:2004 Nuclear power plants - Instrumentation and control systems important to safety - Separation
EN ISO 11064-1:2000 Ergonomic design of control centres - Part 1: Principles for the design of control centres (ISO 11064-1:2000)
IEC 60964:2009 Nuclear power plants - Control rooms - Design
IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
IEC 62646:2016 Nuclear power plants - Control rooms - Computer-based procedures
EN 61513:2013 Nuclear power plants - Instrumentation and control important to safety - General requirements for systems
IEC 61508-2:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508)
EN 60709:2010 Nuclear power plants - Instrumentation and control systems important to safety - Separation
EN ISO 11064-3:1999/AC:2002 ERGONOMIC DESIGN OF CONTROL CENTRES - PART 3: CONTROL ROOM LAYOUT (ISO 11064-3:1999/Cor.1:2002)
IEC 62241:2004 Nuclear power plants - Main control room - Alarm functions and presentation

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more