Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 61643-311:2013

Current
Current

The latest, up-to-date edition.

Components for low-voltage surge protective devices Performance requirements and test circuits for gas discharge tubes (GDT)
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-09-2013

1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Service conditions
5 Mechanical requirements and materials
6 General
7 Electrical requirements
8 Test and measurement procedures and circuits
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Pertains to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1000 V (r.m.s.) a.c. and 1500 V d.c..

IEC 61643-311:2013 is applicable to gas discharge tubes (GDT) used for overvoltage protection in telecommunications, signalling and low-voltage power distribution networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c..They are defined as a gap, or several gaps with two or three metal electrodes hermetically sealed so that gas mixture and pressure are under control. They are designed to protect apparatus or personnel, or both, from high transient voltages. This standard contains a series of test criteria, test methods and test circuits for determining the electrical characteristics of GDTs having two or three electrodes. This standard does not specify requirements applicable to complete surge protective devices, nor does it specify total requirements for GDTs employed within electronic devices, where precise coordination between GDT performance and surge protective device withstand capability is highly critical. This second edition of IEC 61643-311 cancels and replaces the first edition published in 2001. It constitutes a technical revision. Specific changes with respect to the previous edition are: Addition of performance values. Key words: gas discharge tubes (GDT), overvoltage protection in telecommunications, signalling and low-voltage power distribution networks, nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c.

Committee
PEL/37
DevelopmentNote
Supersedes 98/203339 DC. (05/2002) Supersedes 10/30184592 DC. (10/2013)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
I.S. EN 61643-311:2013 Identical
IEC 61643-311:2013 Identical
NF EN 61643-311 : 2014 Identical
NBN EN 61643-311 : 2013 Identical
DIN EN 61643-311 : 2014 Identical
EN 61643-311:2013 Identical
UNE-EN 61643-311:2014 Identical

BS 1363-1:2016+A1:2018 13 A plugs, socket-outlets, adaptors and connection units Specification for rewirable and non-rewirable 13 A fused plugs

IEC 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
EN 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
IEEE C62.31-2006 IEEE Standard Test Methods for Low-Voltage Gas-Tube Surge-Protective Device Components
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
DIN VDE 0845-1 : 1987 PROTECTION OF TELECOMMUNICATION SYSTEMS AGAINST LIGHTNING, ELECTROSTATIC DISCHARGES AND OVER-VOLTAGES FROM ELECTRIC POWER INSTALLATIONS; PROVISIONS AGAINST OVER-VOLTAGES
EN 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more