Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure. Unplasticized poly(vinyl chloride) (PVC U) Fitness for purpose of the system
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-01-2010

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions, symbols and abbreviations
4 Fitness for purpose of joints and the system
Annex A (normative) - Assemblies of imperial (inch)-sized
                      pipes, fittings, valves and ancillaries
Annex B (informative) - Determination of the long-term test
                        pressure by creep consideration
Bibliography

Describes the characteristics for the fitness for purpose of unplasticized poly(vinyl chloride) (PVC-U) piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure.

This part of ISO1452 specifies the characteristics for the fitness for purpose of unplasticized poly(vinyl chloride) (PVC-U) piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to in this part of ISO1452. In conjunction with ISO1452-1, ISO1452-2, ISO1452-3 and ISO1452-4, it is applicable to joints and assemblies with components of PVC-U, other plastics and non-plastics materials intended to be used for the following: water mains and services buried in ground; conveyance of water above ground for both outside and inside buildings; buried and above-ground drainage and sewerage under pressure; It is applicable to piping systems intended for the supply of water under pressure up to and including 25°C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. This part of ISO1452 is also applicable to components for the conveyance of water and waste water up to and including 45°C. For temperatures between 25°C and 45°C, FigureA.1 of ISO1452-2:2009 applies. NOTE The producer and the end-user can come to agreement on the possibilities of use for temperatures above 45°C on a case-by-case basis.

Committee
PRI/88/2
DevelopmentNote
Supersedes 08/30168702 DC. (01/2010) Together with BS EN ISO 1452-1, BS EN ISO 1452-2, BS EN ISO 1452-3 & BS EN ISO 1452-4, it supersedes BS EN 1452-1, BS EN 1452-2, BS EN 1452-3, BS EN 1452-4, BS EN 1452-5 & BS EN 1456-1. (04/2010)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
ISO 1452-5:2009 Identical
EN ISO 1452-5:2010 Identical

ISO 13846:2000 Plastics piping systems End-load-bearing and non-end-load-bearing assemblies and joints for thermoplastics pressure piping Test method for long-term leaktightness under internal water pressure
EN 714:1994 Thermoplastics piping systems - Non-end-load-bearing elastomeric sealing ring type joints beteween pressure pipes and moulded fittings - Test method for leaktighness under internal hydrostatic pressure without end thrust
ISO 1452-1:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 1: General
ISO 1452-4:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 4: Valves
ISO 1452-3:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 3: Fittings
ENV 1452-7:2000 Plastics piping systems for water supply - Unplasticized poly(vinyl chloride) (PVC-U) - Part 7: Guidance for the assessment of conformity
EN 715:1994 Thermoplastics piping systems - End-load bearing joints between small diameter pressure pipes and fittings - Test method for leaktightness under internal water pressure, including end thrust
ISO 13783:1997 Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) end-load-bearing double-socket joints — Test method for leaktightness and strength while subjected to bending and internal pressure
ISO 13844:2015 Plastics piping systems Elastomeric-sealing-ring-type socket joints for use with plastic pressure pipes Test method for leaktightness under negative pressure, angular deflection and deformation
ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 2: Pipes
ISO/TR 4191:2014 Plastics piping systems for water supply Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O) Guidance for installation
ISO 13845:2015 Plastics piping systems Elastomeric-sealing-ring-type socket joints for use with thermoplastic pressure pipes Test method for leaktightness under internal pressure and with angular deflection

View more information
$294.12
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more