0 Introduction
1 Scope
2 Field of application
3 References
Section one: General recommendations
4 Definitions and symbols
5 Specified duty
6 General requirements for tests
Section two: Measurement methods
7 Measurement of rate of flow
8 Measurement of head
9 Measurement of speed of rotation
10 Measurement of power input
11 Measurement of pump efficiency by the thermodynamic
    method
12 Cavitation tests
Annexes
A Estimation and analysis of uncertainties
B Comparison of test results with specified duty
C Thermodynamic properties of water and assessment of the
    accuracy of efficiency measurements by the thermodynamic
    method
D Other cavitation tests
E Friction losses

General recommendations, measurements of rate of flow, head, speed of rotation, power input and pump efficiency by the thermodynamic method. Also, cavitation tests, estimating of and analysis of uncertainties and comparison of tests results with specified duty.

Committee
MCE/6
DevelopmentNote
Supersedes BS 5316-3(1988). (10/2005)
DocumentType
Standard
Pages
110
PublisherName
British Standards Institution
Status
Current
Supersedes

ISO 3534:1977 Statistics — Vocabulary and symbols
ISO 2548:1973 Centrifugal, mixed flow and axial pumps Code for acceptance tests Class C
ISO 5168:2005 Measurement of fluid flow — Procedures for the evaluation of uncertainties
ISO 4373:2008 Hydrometry Water level measuring devices
ISO 2975-3:1976 Measurement of water flow in closed conduits — Tracer methods — Part 3: Constant rate injection method using radioactive tracers
ISO 555-3:1982 Liquid flow measurement in open channels Dilution methods for measurement of steady flow Part 3: Constant rate injection method and integration method using radioactive tracers
ISO 555-2:1987 Liquid flow measurement in open channels Dilution methods for the measurement of steady flow Part 2: Integration method
ISO 3354:2008 Measurement of clean water flow in closed conduits — Velocity-area method using current-meters in full conduits and under regular flow conditions
ISO 2975-7:1977 Measurement of water flow in closed conduits — Tracer methods — Part 7: Transit time method using radioactive tracers
ISO 2975-1:1974 Measurement of water flow in closed conduits — Tracer methods — Part 1: General
IEC 60193:1999 Hydraulic turbines, storage pumps and pump-turbines - Model acceptance tests
ISO 2975-6:1977 Measurement of water flow in closed conduits — Tracer methods — Part 6: Transit time method using non-radioactive tracers
IEC 60041:1991 Field acceptance tests to determine the hydraulic performance of hydraulic turbines, storage pumps and pump-turbines
ISO 5167:1980 Measurement of fluid flow by means of orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full
ISO 4359:2013 Flow measurement structures — Rectangular, trapezoidal and U-shaped flumes
ISO 8316:1987 Measurement of liquid flow in closed conduits Method by collection of the liquid in a volumetric tank
IEC 60497:1976 International code for model acceptance tests of storage pumps
ISO 3555:1977 Centrifugal, mixed flow and axial pumps — Code for acceptance tests — Class B
ISO 3846:2008 Hydrometry Open channel flow measurement using rectangular broad-crested weirs
IEC 60034-2:1972 Rotating electrical machines. Part 2: Methods for determining losses and efficiency of rotating electrical machinery from tests (excluding machines for traction vehicles)
ISO 7194:2008 Measurement of fluid flow in closed conduits — Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot static tubes
ISO 2186:2007 Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements
ISO 3966:2008 Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes
ISO 4360:2008 Hydrometry Open channel flow measurement using triangular profile weirs
ISO 2975-2:1975 Measurement of water flow in closed conduits — Tracer methods — Part 2: Constant rate injection method using non-radioactive tracers

View more information
$615.68
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more