1 Scope
2 Normative references
3 Definitions
4 Symbols and abbreviations
5 Monitoring programme
    5.1 Monitoring system
    5.2 Constituents to be measured
    5.3 Operating data to be recorded
6 Arrangement of monitoring system
    6.1 Measurement locations for gaseous emission
    6.2 Point measurement of gaseous emissions
    6.3 Path measurement gaseous emissions
    6.4 Particulate measurement location
    6.5 Measurement locations for reference measurements
7 Components of the monitoring system
    7.1 Extractive sampling
    7.2 Analysers
8 Calibration, functional checking and maintenance
    8.1 General
    8.2 Reference measurements
    8.3 Relative accuracy test and validation procedure
    8.4 Drift tests
    8.5 Frequency of calibration
    8.6 Supply of calibration gases (where applicable)

Defines the monitoring programme and requirements for selecting and operating hardware for use for continuous measuring over an extended time (not limited). Monitors concentration and absolute magnitude of specified emissions in exhaust gas and essential operating conditions.

This part of ISO11042 establishes the monitoring programme and the requirements for the selection and operation of hardware to be used for continuous measurement over an extended, not limited, time. The concentration and absolute magnitude of specified emissions in the exhaust gas are monitored as well as related gaseous components from gas turbines together with essential operating conditions. Appropriate terms and symbols in addition to those defined in ISO11042-1 are used. It presents requirements for the monitoring environment, the instrumentation and recording as well as for quality assessment and correction of data.

This part of ISO11042 is applicable for all gas turbines producing mechanical shaft power and/or which are used as drivers for electrical generation as well as marine application but excluding application in aircraft. It can be used as a basis for installations equipped to utilize exhaust heat.

This part of ISO11042 is applicable for gas turbines which utilize the open cycle process. It is also applicable as a basis for gas turbines which utilize the semi-closed cycle and for gas turbines equipped with free piston compressors or with special heat sources.

This part of ISO11042 is not intended to be used for acceptance testing for gas turbine exhaust emissions except by mutual agreement between the parties involved.

Constituents, which are released into the air in significant quantities, greater than a certain limiting value, should be monitored. Such values are determined by mutual agreement between the parties involved.

In general, this part of ISO11042 requires that the following parameters be continuously monitored: emissions, diluent gas (O2, CO2), exhaust gas flow (calculated or, if required, measured), fuel consumption and gas turbine plant performance. Chemical analysis of the fuel is required on fuel samples taken at regular intervals.

Committee
MCE/16
DevelopmentNote
Supersedes 94/702777 DC. (07/2005) Reviewed and confirmed by BSI, January 2007. (12/2006)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
ISO 11042-2:1996 Identical

ISO 10155:1995 Stationary source emissions — Automated monitoring of mass concentrations of particles — Performance characteristics, test methods and specifications
ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
ISO 3977-2:1997 Gas turbines — Procurement — Part 2: Standard reference conditions and ratings
ISO 3977-1:1997 Gas turbines — Procurement — Part 1: General introduction and definitions
ISO 4225:1994 Air quality General aspects Vocabulary
ISO 7168:1985 Air quality Presentation of ambient air quality data in alphanumerical form
ISO 11042-1:1996 Gas turbines — Exhaust gas emission — Part 1: Measurement and evaluation
ISO 2314:2009 Gas turbines — Acceptance tests
ISO 6879:1995 Air quality — Performance characteristics and related concepts for air quality measuring methods
ISO 7504:2015 Gas analysis Vocabulary
ISO 10396:2007 Stationary source emissions — Sampling for the automated determination of gas emission concentrations for permanently-installed monitoring systems

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more