Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS ISO 13885-1:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Binders for paints and varnishes. Gel permeation chromatography (GPC) Tetrahydrofuran (THF) as eluent

Available format(s)

Hardcopy , PDF

Superseded date

14-07-2020

Language(s)

English

Published date

30-11-2008

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
   5.1 General
   5.2 Eluent supply
   5.3 Pump
   5.4 Injection system
   5.5 Columns
   5.6 Column temperature control
   5.7 Detector
   5.8 Data acquisition
6 Eluent
7 Calibration of the apparatus
   7.1 General
   7.2 Specification for the calibration standard
   7.3 Preparation of the calibration solutions for injection
   7.4 Conditions for calibration runs
   7.5 Measurement of retention volume/time
   7.6 Plotting the calibration curve
8 Sampling
9 Preparation for the test
   9.1 Preparation of the injection solution
   9.2 Preparation of the apparatus
10 Conditions of analysis
11 Data acquisition and evaluation
   11.1 General
   11.2 Calculation of the net chromatogram from the
        raw data
   11.3 Calculation of the average values
   11.4 Calculation of the distribution curves
12 Precision
   12.1 General
   12.2 Repeatability
   12.3 Reproducibility
13 Test report
   13.1 General
   13.2 General data on the equipment and settings
   13.3 Special data on the sample
Annex A (normative) - Calculation of experimental parameters for
        different column sizes
Annex B (informative) - Example of a data sheet for a polymer
        standard
Annex C (informative) - Further information
Bibliography

Specifies the determination of the molar-mass distribution, number-average molar mass M[n] and mass-average molar mass M[w] of polymers that are soluble in THF (tetrahydrofuran) by gel permeation chromatography (GPC).

Committee
STI/10
DevelopmentNote
Supersedes BS 6782-14(1999) and 07/30169420 DC. (11/2008)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
ISO 13885-1:2008 Identical

ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
ISO 15528:2013 Paints, varnishes and raw materials for paints and varnishes Sampling
ISO 1513:2010 Paints and varnishes Examination and preparation of test samples

View more information
$407.85
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more