1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Reactions
6 Requirement
7 Reagents
8 Apparatus
   8.1 Sampling equipment
   8.2 Analytical instrumentation
9 Occupational exposure assessment
   9.1 General
   9.2 Static (area) sampling
   9.3 Personal sampling
   9.4 Selection of measurement conditions and
        measurement pattern
10 Sampling
   10.1 Preliminary considerations
   10.2 Preparation for sampling
   10.3 Sampling position
   10.4 Collection of samples
   10.5 Transportation of samples
11 Analysis
12 Expression of results
   12.1 Calculation of the air sample volumes
   12.2 Calculation of airborne mercury concentrations
13 Method performance
   13.1 Detection and quantification limits
   13.2 Upper limits of the analytical range
   13.3 Blank values
   13.4 Bias and precision
   13.5 Effects on sampler performance
   13.6 Collection efficiency, breakthrough volume and
        sampling capacity of sorbent tubes
   13.7 Storage stability
   13.8 Interferences
14 Test report
Annex A (informative) Temperature and pressure correction
Annex B (informative) Figures
Bibliography

Describes a procedure for determination of the mass concentration of mercury vapour in workplace air using a method of gold-amalgam collection with analysis by either cold vapour atomic absorption spectrometry (CVAAS) or cold vapour atomic fluorescence spectrometry (CVAFS).

This International Standard specifies a procedure for determination of the mass concentration of mercury vapour in workplace air using a method of gold-amalgam collection with analysis by either cold vapour atomic absorption spectrometry (CVAAS) or cold vapour atomic fluorescence spectrometry (CVAFS). The procedure specifies a number of sampling methods for different applications. When it is known that no particulate inorganic mercury compounds are used in the workplace and that none are produced in the processes carried out, samples of mercury vapour are collected using a pumped sorbent tube containing porous gold-coated diatomaceous earth. Suitable sorbent tubes are commercially available or they can be made from sorbent prepared by pyro-decomposition of chloroauric acid [hydrogen tetrachloroaurate(III)] sintered on diatomaceous earth. When both mercury vapour and particulate inorganic mercury compounds could be present in the test atmosphere, samples of mercury vapour are collected using a pumped sorbent tube fitted with a quartz fibre prefilter to remove particulate inorganic mercury compounds. If desired, the procedure described in ISO17733 can be used to collect and analyse separate samples for measurement of particulate inorganic mercury compounds. When it is known that no elemental mercury is used in the workplace and that no mercury vapour is produced in the processes carried out, the procedure described in ISO17733 can be used, if desired, to collect and analyse samples for measurement of particulate inorganic mercury compounds. The procedure is highly sensitive and suitable for static sampling or for determination of short-term personal exposure to mercury vapour in workplace air. The lower limit of the working range of the procedure is governed by the lower limit of the analytical range of the CVAAS or CVAFS instrument, which is approximately 0,01ng of mercury for a sorbent tube containing 80mg of sorbent (see 13.1). The upper limit of the working range of the procedure is governed by the upper limit of the analytical range of the CVAAS or CVAFS instrument, e.g. about 1μg of mercury (see 13.2). The sampling capacity of one commercially available sorbent tube has been shown to be greater than 2μg. The concentration ranges of mercury in air for which the procedure is applicable are determined in part by the sampling method selected by the user. The procedure is suitable for making short-term measurements (e.g. 15min) when sampling at a flow rate of between 100ml min−1 and 1000ml min−1 using a commercially available sorbent tube. For assessment of long-term exposure, such as 8h, this procedure can be used with sampling flow rate of 100ml min−1 in workplaces where the concentration of mercury vapour is expected to be lower than 20μg m−3. If the expected concentration of mercury vapour is higher than 20μg m−3, it is necessary to use the procedure prescribed in ISO17733. The method is unsuitable for making measurements of mercury vapour in air when chlorine is present in the atmosphere, e.g. in chloralkali works (see 13.8.1). Gaseous organo-mercury compounds can cause a positive interference (see 13.8.2).

Committee
EH/2/2
DevelopmentNote
Supersedes 05/30124529 DC. (03/2007)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
ISO 20552:2007 Identical

ASTM E 1370 : 2014 : REDLINE Standard Guide for Air Sampling Strategies for Worker and Workplace Protection
ASTM D 4840 : 1999 Standard Guide for Sampling Chain-of-Custody Procedures
ISO 7708:1995 Air quality — Particle size fraction definitions for health-related sampling
EN 1076:2009 Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods
EN 482:2012+A1:2015 Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents
ISO 3534-2:2006 Statistics Vocabulary and symbols Part 2: Applied statistics
ISO 17733:2015 Workplace air Determination of mercury and inorganic mercury compounds Method by cold-vapour atomic absorption spectrometry or atomic fluorescence spectrometry
EN 1540:2011 Workplace exposure - Terminology
EN 1232:1997 Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods

View more information
$478.43
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session