Thermal insulation. Building elements. 7IIn-situ7R measurement of thermal resistance and thermal transmittance Heat flow meter method
Published date

31-08-2014

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and units
4 Apparatus
5 Calibration procedure
6 Measurements
7 Analysis of the data
8 Corrections for the thermal resistance and
   the finite dimension of the HFM
9 Accuracy
10 Test report
Annex A (normative) - Heat transfer at surfaces
         and U-value measurement
Annex B (normative) - Dynamic analysis method
Annex C (normative) - Examination of the structure
         of the element
Annex D (informative) - Perturbations caused by the
         heat flow meter
Annex E (informative) - Checking the accuracy of the
         measurement system of heat flow rate
Annex F (informative) - Heat storage effects
Bibliography

Explains the heat flow meter method for the measurement of the thermal transmission properties of plane building components, primarily consisting of opaque layers perpendicular to the heat flow and having no significant lateral heat flow.

This part of ISO9869 describes the heat flow meter method for the measurement of the thermal transmission properties of plane building components, primarily consisting of opaque layers perpendicular to the heat flow and having no significant lateral heat flow. The properties which can be measured are: the thermal resistance, R, and thermal conductance, Λ, from surface to surface; the total thermal resistance, RT, and transmittance from environment to environment, U, if the environmental temperatures of both environments are well defined. The heat flow meter measurement method is also suitable for components consisting of quasi homogeneous layers perpendicular to the heat flow, provided that the dimensions of any inhomogeneity in close proximity to the heat flow meter (HFM) is much smaller than its lateral dimensions and are not thermal bridges which can be detected by infrared thermography (see 6.1.1). This part of ISO9869 describes the apparatus to be used, the calibration procedure for the apparatus, the installation and the measurement procedures, the analysis of the data, including the correction of systematic errors and the reporting format. NOTE 1 It is not intended as a high precision method replacing the laboratory instruments such as hot boxes that are specified in ISO8990:1994. NOTE 2 For other components, an average thermal transmittance may be obtained using a calorimeter or by averaging the results of several heat flow meter measurements. NOTE 3 In building with large heat capacities, the average thermal transmittance of a component can be obtained by measurement over an extended period, or the apparent transmittance of the part can be estimated by a dynamic analysis of its thermal absorption response (see AnnexB).

Committee
B/540/8
DevelopmentNote
Supersedes 13/30279556 DC. (09/2014)
DocumentType
Standard
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
ISO 9869-1:2014 Identical

ISO 8302:1991 Thermal insulation — Determination of steady-state thermal resistance and related properties — Guarded hot plate apparatus
ISO 8301:1991 Thermal insulation Determination of steady-state thermal resistance and related properties Heat flow meter apparatus
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
ISO 8990:1994 Thermal insulation — Determination of steady-state thermal transmission properties — Calibrated and guarded hot box
ISO 6781:1983 Thermal insulation — Qualitative detection of thermal irregularities in building envelopes — Infrared method
ISO 7345:1987 Thermal insulation Physical quantities and definitions

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more