MEDICAL ELECTRICAL EQUIPMENT - PART 2-16: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HAEMODIALYSIS, HAEMODIAFILTRATION AND HAEMOFILTRATION EQUIPMENT
Available format(s)

Hardcopy , PDF

Superseded date

24-01-2019

Language(s)

English

Published date

01-01-2016

FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.8 Protection against electrical HAZARDS from ME
       EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME
       EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
       HAZARDS
201.11 Protection against excessive temperatures and other
       HAZARDS
201.12 Accuracy of controls and instruments and protection
       against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
       and ME SYSTEMS
202 Electromagnetic compatibility - Requirements and tests
208 General requirements, tests and guidance for alarm
       systems in medical electrical equipment and medical
       electrical systems
210 Process requirements for the development of PHYSIOLOGIC
       CLOSED-LOOP CONTROLLERS
211 Requirements for MEDICAL ELECTRICAL EQUIPMENT
       and MEDICAL ELECTRICAL SYSTEMS used in the
       HOME HEALTHCARE ENVIRONMENT
Annexes
Annex G (normative) - Protection against HAZARDS of
        ignition of flammable anaesthetic mixtures
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - Examples of HAZARDS, foreseeable
         sequences of events, and HAZARDOUS SITUATIONS in
         HAEMODIALYSIS EQUIPMENT
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications
Annex ZZ (informative) - Coverage of Essential Requirements
         of EU Directives

Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HAEMODIALYSIS, HAEMODIAFILTRATION and HAEMOFILTRATION EQUIPMENT, hereafter referred to as HAEMODIALYSIS EQUIPMENT.

Committee
CT 62
DevelopmentNote
Classificazione CEI 62-98 (08/2001) Supersedes CEI 62-19 (03/2004) 1ED 1999 Edition along with its corrigendum is valid until 14-04-2018. (02/2016) Italian translation of 2ED 2016 Issued on 01/01/2018. (02/2018)
DocumentType
Standard
Pages
74
PublisherName
Comitato Elettrotecnico Italiano
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60601-2-16 : 4.0 Identical
EN 60601-2-16:2015 Identical

ISO 3744:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane
IEC 60601-1-6:2010+AMD1:2013 CSV Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
ISO 8638:2010 Cardiovascular implants and extracorporeal systems Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters
IEC 60601-1-10:2007+AMD1:2013 CSV Medical electrical equipment - Part 1-10: General requirements forbasic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loopcontrollers
EN 60601-1-6:2010/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-6: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: USABILITY (IEC 60601-1-6:2010/A1:2013)
EN 60601-1-10:2008/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-10: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR THE DEVELOPMENT OF PHYSIOLOGIC CLOSED-LOOP CONTROLLERS (IEC 60601-1-10:2007)
IEC 60601-1-8:2006+AMD1:2012 CSV Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems
IEC 62366:2007+AMD1:2014 CSV Medical devices - Application of usability engineering to medical devices
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN ISO 3744:2010 Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2010)
EN ISO 8638:2014 Cardiovascular implants and extracorporeal systems - Extracorporeal blood circuit for haemodialysers, haemodiafilters and haemofilters (ISO 8638:2010)
EN 62366 : 2008 AMD 1 2015 MEDICAL DEVICES - APPLICATION OF USABILITY ENGINEERING TO MEDICAL DEVICES (IEC 62366:2007/A1:2014)
ISO 594-2:1998 Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings
EN 60601-1-11:2015 Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
EN 60601-1-8:2007/A11:2017 MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012)

View more information
$264.06
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more