Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CEI UNI EN 45510-2-8 : 2006

Current
Current

The latest, up-to-date edition.

GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES
Available format(s)

Hardcopy , PDF

Language(s)

English - Italian

Published date

01-01-2006

1 Scope
2 Normative references
3 Definitions
4 Brief overall project description
5 Extent of supply
6 Terminal points
7 Operational requirements
8 Life expectancy
9 Performance requirements
10 Design and fabrication
11 Maintenance requirements
12 Technical documentation requirements
13 Applicable legislation, regulations, standards
   and further requirements
14 Evaluation criteria
15 Quality measures
16 Site factors
17 Verification of specified performance
Annex A (informative) - Bibliography
Annex B (informative) - Information for selection
        of power cables

Provides guidance on writing the technical specification for the procurement of low voltage (LV) and medium voltage (MV) power cables for use in electricity generating stations (power stations).

Committee
CT 20
DevelopmentNote
Classificazione CEI 20-78. (04/2006)
DocumentType
Standard
Pages
42
PublisherName
Comitato Elettrotecnico Italiano
Status
Current

Standards Relationship
EN 45510-2-8 : 2004 Identical
EN 45510-2-8:2004 Identical

EN 50268-1:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 1: Apparatus
HD 622 S1:1996/A2:2005 Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
IEC 60986:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
IEC 60724:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 60502:1994 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
IEC 60949:1988 Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects
EN 50266-1:2001 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 1: Apparatus
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
EN 50268-2:1999 Common test methods for cables under fire conditions - Measurement of smoke density of cables burning under defined conditions - Part 2: Procedure
EN 50265-2-2:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-2: Procedures - Diffusion flame
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
EN ISO 8402 : 1995 QUALITY MANAGEMENT AND QUALITY ASSURANCE - VOCABULARY
IEC 60331:1970 Fire-resisting characteristics of electric cables
EN 50265-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 1: Apparatus
HD 604 S1:1994/A3:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame

View more information
$77.52
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more