CAN/CSA-C22.2 NO. 60947-1-13 (R2018)

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE)
Available format(s)

Hardcopy , PDF

Superseded date

01-01-2022

Language(s)

English, French

Published date

01-01-2013

Preface
National Differences
FOREWORD
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (informative) - Examples of utilization categories for
        low-voltage switchgear and controlgear
Annex B (informative) - Suitability of the equipment when
        conditions for operation in service differ from the
        normal conditions
Annex C (normative) - Degrees of protection of enclosed
        equipment
Annex D (informative) - Examples of terminals
Annex E (informative) - Description of a method for adjusting
        the load circuit
Annex F (informative) - Determination of short-circuit
        power-factor or time-constant
Annex G (informative) - Measurement of creepage distances
        and clearances
Annex H (informative) - Correlation between the nominal
        voltage of the supply system and the rated impulse
        withstand voltage of equipment
Annex J (informative) - Items subject to agreement between
        manufacturer and user
Annex K
Annex L (normative) - Terminal marking and distinctive number
Annex M (normative) - Flammability test
Annex N (normative) - Requirements and tests for equipment
        with protective separation
Annex O (informative) - Environmental aspects
Annex P (informative) - Terminal lugs for low voltage
        switchgear and controlgear connected to copper
       conductors
Annex Q (normative) - Special tests - Damp heat, salt mist,
        vibration and shock
Annex R (informative) - Application of the metal foil for
        dielectric testing on accessible parts during operation
        or adjustment
Annex S (normative) - Digital inputs and outputs
Bibliography
Annex DVA (informative)
ANNEX DVB (normative) - Standard references
Annex DVC (normative) - Secondary Circuits and Circuits
          Supplied by Battery
Annex DVD (normative) - Short-Circuit Test Circuit Calibration
          and Measurement Techniques

Applicable, when required by the relevant product standard, to switchgear and controlgear hereinafter referred to as 'equipment' and intended to be connected to circuits, the rated voltage of which does not exceed 1000 V a.c. or 1500 V d.c.

Preface This is the harmonized ANCE, CSA Group, and UL standard for Low-Voltage Switchgear and Controlgear - Part 1: General rules. It is the second edition of NMX-J-515-ANCE, the second edition of CAN/CSA-C22.2 No. 60947-1, and the fifth edition of UL 60947-1. This edition of NMX-J-515-ANCE cancels the previous edition published in 2007. This edition of CAN/CSA-C22.2 No. 60947-1 supersedes the previous edition published in 2007. This edition of UL 60947-1 supersedes the previous edition published in 2007. This standard is based on publication IEC 60947-1, fifth Edition (2007). Scope and object This standard applies, when required by the relevant product standard to switchgear and controlgear hereinafter referred to as \"equipment\" and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c. It does not apply to low-voltage switchgear and controlgear assemblies which are dealt with in IEC 60439. NOTE - In certain clauses or subclauses of this standard, the equipment covered by this standard is also referred to as \"device\", to be consistent with the text of such clauses or subclauses. The object of this standard is to state those general rules and requirements which are common to low-voltage equipment as defined in 1.1, including for example: - definitions; - characteristics; - information supplied with the equipment; - normal service, mounting and transport conditions; - constructional and performance requirements; - verification of characteristics and performance. Digital inputs and/or digital outputs contained in switchgear and controlgear, and intended to be compatible with programmable controllers (PLCs) are covered by Annex S. 1.1DV.1 D2 Modification to 1.1 by adding the following: 1.1DV.1.1 This equipment is intended for installation in accordance with the national installation codes for use in ordinary locations. See Annex DVB, Table DVB.3, Ref. No. 14. 1.1DV.1.2 \"IEC 60947-2: Part 2: Circuit-breakers\" does not apply. They are covered in Annex DVB, Table DVB.3, Ref. No. 3. 1.1DV.1.3 \"IEC 60947-3: Part 3: Switches, disconnectors, switch-disconnectors and fuse combination units\" do not apply. They are covered in Annex DVB, Table DVB.3, Ref. No. 1. 1.1DV.2 DR Modification to 1.1 by adding 1.1DV.2.1 and 1.1DV.2.2: 1.1DV.2.1 In Mexico and the United States with respect to the national installation codes, equipment operating at 600 V and less is considered low-voltage equipment. in Canada, with respect to the national installation codes, equipment operating at more than 750 V is considered high voltage equipment. 1.1DV.2.2 Enclosed equipment intended for use as service equipment is to comply with the applicable requirements in this standard and with Annex DVB, Table DVB.3, Ref. No. 7. In Mexico, this requirement does not apply.

DevelopmentNote
Also numbered as UL 60947-1. (04/2007) Supersedes CSA E947.1. (02/2008) Also numbered as NMX-J-515-ANCE. (08/2013)
DocumentType
Standard
ISBN
978-1-55491-668-9
Pages
321
PublisherName
Canadian Standards Association
Status
Superseded
Supersedes

CSA C22.2 No. 61730-1 : 2011 : INC : AMD 2 : 2015 : R2016 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION
CSA C22.2 No. 61730-1 : 2011 : INC : AMD 1 : 2013 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION
CSA C22.2 No. 61730-1 : 2011 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION
CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
UL 60947-7-2:4ED 2017-01 Low-Voltage Switchgear and Controlgear - Part 7-2: Ancillary Equipment - Protective Conductor Terminal Blocks for Copper Conductors
CSA C22.2 No. 61730-2 :2011 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING
CSA C22.2 No. 61730-2 : 2011 : INC : AMD 1 : 2013 : R2016 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING
CSA C22.2 NO. 60947-5-2:14 (R2019) Low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches (Bi-national standard, with UL 60947-5-2)
UL 60947-7-1:4ED 2017-01 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
CSA C22.2 No. 272 : 2014 WIND TURBINE ELECTRICAL SYSTEMS
UL 60947-7-3:3ED 2017-01 Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks
CSA C22.2 NO. 60947-4-1:14 (R2019) Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters ( Bi-national standard, with UL 60947-4-1)
CSA C22.2 No. 61730-1 : 2011 : INC : UPD 1 : 2013 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION
CSA C22.2 No. 61730-2 : 2011 : INC : UPD 1 : 2013 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING
CSA C22.2 No. 61730-2 : 2011 : INC : AMD 1 : 2013 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING
CSA C22.2 No. 61730-1 : 2011 : INC : AMD 2 : 2015 PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION
CSA C22.2 NO. 60947-5-1:14 (R2019) Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices (Bi-national standard, with UL 60947-5-1)
CAN/CSA-C22.2 NO. 60947-7-1:17 Low-voltage switchgear and controlgear ? Part 7-1: Ancillary equipment ? Terminal blocks for copper conductors (Trinational standard with NMX-J-538/7-1-ANCE and UL 60947-7-1)
CAN/CSA-C22.2 NO. 60947-7-2:17 Low-voltage switchgear and controlgear ? Part 7-2: Ancillary equipment ? Protective conductor terminal blocks for copper conductors (Trinational standard with NMX-J-538/7-2-ANCE and UL 60947-7-2)
CAN/CSA-C22.2 NO. 60947-7-3:17 Low-voltage switchgear and controlgear ? Part 7-3: Ancillary equipment ? Safety requirements for fuse terminal blocks (Trinational standard NMX-J-538/7-3-ANCE with UL 60947-7-3)
CSA C22.2 NO. 60947-4-2:14 (R2019) Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters ( Bi-national standard, with UL 60947-4-2)

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 60947-8:2003+AMD1:2006+AMD2:2011 CSV Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines
IEC 60228:2004 Conductors of insulated cables
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
UL 60947-7-3:3ED 2017-01 Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
UL 248-8:3ED 2011-05 Low-Voltage Fuses - Part 8: Class J Fuses
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
CSA C22.2 No. 0.2 : 2016 INSULATION COORDINATION
WC 8:1988 ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
CSA C233.1 : 1987 GAPLESS METAL OXIDE SURGE ARRESTERS FOR ALTERNATING CURRENT SYSTEMS
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
UL 6 : 2014 ELECTRICAL RIGID METAL CONDUIT - STEEL
ASTM B 172 : 2017 : REDLINE Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
UL 248-12:3ED 2011-05 Low-Voltage Fuses - Part 12: Class R Fuses
UL 248-11:3ED 2011-05 Low-Voltage Fuses - Part 11: Plug Fuses
IEC 60447:2004 Basic and safety principles for man-machine interface, marking and identification - Actuating principles
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
UL 248-4:2ED 2000-08 Low-Voltage Fuses - Part 4: Class CC Fuses
IEC TR 60344:2007 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide
IEC 60364-4-44:2007+AMD1:2015 CSV Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
UL 248-10:3ED 2011-05 Low-Voltage Fuses - Part 10: Class L Fuses
UL 60947-7-1:4ED 2017-01 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
UL 248-9:2ED 2000-08 Standard for Low-Voltage Fuses - Part 9: Class K Fuses
WC 3-1992 RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
UL 60947-7-2:4ED 2017-01 Low-Voltage Switchgear and Controlgear - Part 7-2: Ancillary Equipment - Protective Conductor Terminal Blocks for Copper Conductors
UL 746A:6ED 2012-09 Polymeric Materials - Short Term Property Evaluations
UL 248-1 : 3 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS
IEC 61131-2:2017 Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
CSA C22.2 No. 14 : 2013 INDUSTRIAL CONTROL EQUIPMENT
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
CSA C22.2 NO. 60947-4-1:14 (R2019) Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters ( Bi-national standard, with UL 60947-4-1)
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
UL 248-5:2ED 2000-08 Standard for Low-Voltage Fuses - Part 5: Class G Fuses
WC 7-1988 CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
$1,535.83
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more