Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA C22.2 NO. 60947-5-2:14 (R2019)

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches (Bi-national standard, with UL 60947-5-2)
Available format(s)

Hardcopy , PDF

Superseded date

01-01-2022

Language(s)

English, French

Published date

01-01-2014

Preface
NATIONAL DIFFERENCES
FOREWORD
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (normative) - Specification sheets
Annex B (normative) - Class II PROXIMITY SWITCHES insulated
        by ENCAPSULATION - Requirements and tests
Annex C (normative) - Additional requirements for PROXIMITY
        SWITCHES with integrally connected cables
Annex D (normative) - Integral connectors for plug-in
        PROXIMITY SWITCHES
Annex E (normative) - Additional requirements for PROXIMITY
        SWITCHES suitable for use in strong magnetic fields
Annex F (informative) - Symbols for PROXIMITY SWITCHES
Annex 101.DVA - Additional requirements for PROXIMITY
                SWITCHES with integrally connected
                cables (normative)
Annex 101.DVB - National Standard References (normative)

Pertains to INDUCTIVE and CAPACITIVE PROXIMITY SWITCHES that sense the presence of metallic and/or non-metallic objects, ULTRASONIC PROXIMITY SWITCHES that sense the presence of sound reflecting objects, PHOTOELECTRIC PROXIMITY SWITCHES that sense the presence of objects and NON-MECHANICAL MAGNETIC PROXIMITY SWITCHES that sense the presence of objects with a MAGNETIC FIELD.

Preface This is the harmonized CSA Group and UL standard for Low-Voltage Switchgear and Controlgear - Part 5-2: Control Circuit Devices and Switching Elements - Proximity Switches. It is the first edition of CAN/CSA-C22.2 No. 60947-5-2, and the third edition of UL 60947-5-2. This standard is based on IEC 60947-5-2, Edition 2.2, which is based on the second edition (1997), and its amendment 1 (1999) and its amendment 2 (2003). This standard has been approved as a National Standard of Canada by the Standards Council of Canada (SCC). Scope and object This part of IEC 60947 applies to INDUCTIVE and CAPACITIVE PROXIMITY SWITCHES that sense the presence of metallic and/or non-metallic objects, ULTRASONIC PROXIMITY SWITCHES that sense the presence of sound reflecting objects, PHOTOELECTRIC PROXIMITY SWITCHES that sense the presence of objects and NON-MECHANICAL MAGNETIC PROXIMITY SWITCHES that sense the presence of objects with a MAGNETIC FIELD. These PROXIMITY SWITCHES are self-contained, have SEMICONDUCTOR SWITCHING ELEMENTS(S) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c. This Standard is not intended to cover PROXIMITY SWITCHES with analogue outputs. The object of this standard is to state for PROXIMITY SWITCHES: - definitions; - classification; - characteristics; - product information; - normal service, mounting and transport conditions; - constructional and performance requirements; - tests to verify rated characteristics. - 1.1DV.1 DR Modification of 1.1 by adding 1.1DV.1.1 - 1.1DV.1.2: 1.1DV.1.1 This equipment is for use in ordinary locations in accordance with Annex 101.DVB, Reference No. 1. In Canada, general requirements applicable to this equipment are provided in Reference No. 7 of Table 101.DVB. 1.1DV.1.2 These requirements cover electronic PROXIMITY SWITCHES for use on industrial machinery or mass-production industrial equipment as defined by Annex 101.DVB, Reference No. 4. 1.1DV.2 D1 Modification of 1.1 by adding the following: Equipment requirements are intended for use in an ambient temperature of 0 to 40 C unless specified otherwise.

DevelopmentNote
Also numbered as UL 60947-5-2. (04/2014)
DocumentType
Standard
ISBN
978-1-77139-292-1
Pages
144
ProductNote
This standard also refers to CEI 60364, CEI 60947-5-1+A1, CEI 60947-5-1+A2, CEI 61000-3-2+A1, CEI 61000-3-3+A1, CEI 61000-4-2+A1(1998), CEI 61000-4-2+A2(2000), CEI 61000-4-3+A1, CEI 61000-4-4+A1, CEI 61000-4-4+A2, CEI 61000-4-5+A1, CEI 61000-4-6+A1(2000), CEI 61000-4-8+A1, CEI 61000-4-11+A1,
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 61020-5-1:1991 Electromechanical switches for use in electronic equipment - Part 5: Sectional specification for pushbutton switches - Section 1: Blank detail specification
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
CSA C22.2 NO. 60947-5-1:14 (R2019) Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices (Bi-national standard, with UL 60947-5-1)
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
UL 1097:6ED 2012-02 Double Insulation Systems for Use in Electrical Equipment
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
NFPA 79 : 2015 ELECTRICAL STANDARD FOR INDUSTRIAL MACHINERY
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 60947-5-1 : 4.0 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
CSA C22.2 No. 0.2 : 2016 INSULATION COORDINATION
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE)
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
ISO 630:1995 Structural steels Plates, wide flats, bars, sections and profiles
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
CSA C22.2 No. 14 : 2013 INDUSTRIAL CONTROL EQUIPMENT
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
$1,308.22
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more