Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DIN EN 15193:2008-01

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

ENERGY PERFORMANCE OF BUILDINGS - ENERGY REQUIREMENTS FOR LIGHTING
Available format(s)

Hardcopy , PDF

Superseded date

01-10-2017

Language(s)

English

Published date

01-01-2008

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Calculating energy used for lighting
  4.1 Total energy used for lighting
      4.1.1 Total estimated energy
      4.1.2 Total annual energy used for lighting
  4.2 Lighting Energy Numeric Indicator (LENI)
5 Metering
  5.1 General
  5.2 Load segregation
  5.3 Remote metering
6 Calculation of lighting energy in buildings
  6.1 Installed lighting power
      6.1.1 General
      6.1.2 Luminaire
      6.1.3 Luminaire power (P[i])
      6.1.4 Parasitic powers (P[ci] and P[ei])
  6.2 Calculation methods
      6.2.1 Quick method
      6.2.2 Comprehensive method
      6.2.3 Determination of constant illuminance factor F[c]
7 Benchmark of lighting energy requirements
8 Lighting design and practice
Annex A (informative) Metering of lighting circuit
Annex B (informative) Measurement method of total power of
        luminaires and associated parasitic power
      B.1 Introduction
      B.2 Test measurement of luminaire power during normal
           operation
      B.3 Standard test conditions
      B.4 Electrical measuring instruments
      B.5 Test luminaires
      B.6 Test voltage
      B.7 Luminaire power (P[i])
      B.8 Luminaire parasitic power with lamps off (P[pi])
      B.9 Emergency lighting luminaire parasitic input power
           (P[ei])
      B.10 Lighting controls standby parasitic power (P[ci])
      B.11 Default luminaire power for existing lighting
           installations
      B.12 Default parasitic energy for existing lighting
           installations
Annex C (informative) Determination of the daylight dependency
        factor F[D,n]
      C.1 General
      C.2 Building segmentation: Spaces benefiting from daylight
      C.3 Daylight supply
          C.3.1 Vertical fagades
          C.3.2 Rooflights
      C.4 Daylight dependent artificial lighting control, F[D,c]
      C.5 Monthly method
Annex D (informative) Determination of occupancy dependency
        factor F[o]
      D.1 Introduction
      D.2 Detailed determination of F[o]
      D.3 Motivation for the choice of F[o] functions
Annex E (informative) Determination of the constant illuminance
        factor F[c]
      E.1 Introduction
      E.2 Power for constant illuminance factor
      E.3 Constant illuminance factor (F[c])
Annex F (informative) Benchmark values and lighting design criteria
Annex G (informative) Default values
      G.1 The default values for annual operating hours relating
          to building type are given in Table G.1
Annex H (informative) Other considerations
      H.1 Individual dimming
      H.2 Algorithmic lighting
      H.3 Light pipes
      H.4 Lighting installations with scene setting
      H.5 Daylight guidance
          H.5.1 Vertical fagades
          H.5.2 Rooflights
Annex I (informative) List of Symbols
Bibliography
National Annex NA (informative) Comparison of calculation methods
                  used in Germany with those specified in this
                  European Standard

Describes the calculation methodology for the evaluation of the amount of energy used for indoor lighting inside the building and provides a numeric indicator for lighting energy requirements used for certification purposes.

DocumentType
Standard
Pages
82
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded

DIN V 18599-9:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 9: FINAL AND PRIMARY ENERGY DEMAND OF POWER GENERATION PLANTS
DIN V 18599-6:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 6: FINAL ENERGY DEMAND OF VENTILATION SYSTEMS AND AIR HEATING SYSTEMS FOR RESIDENTIAL BUILDINGS
EN 12464-1:2011 Light and lighting - Lighting of work places - Part 1: Indoor work places
DIN V 18599-4:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 4: NET AND FINAL ENERGY DEMAND FOR LIGHTING
DIN V 18599-2:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 2: NET ENERGY DEMAND FOR HEATING AND COOLING OF BUILDING ZONES
DIN V 18599-3:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 3: NET ENERGY DEMAND FOR AIR CONDITIONING
DIN V 18599-5:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 5: FINAL ENERGY DEMAND OF HEATING SYSTEMS
DIN V 18599-7:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 7: FINAL ENERGY DEMAND OF AIR-HANDLING AND AIR-CONDITIONING SYSTEMS FOR NON-RESIDENTIAL BUILDINGS
DIN V 18599-8:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 8: NET AND FINAL ENERGY DEMAND OF DOMESTIC HOT WATER SYSTEMS
EN 12193:2007 Light and lighting - Sports lighting
EN 13032-1:2004+A1:2012 Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 1: Measurement and file format
DIN V 18599-1:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 1: GENERAL BALANCING PROCEDURES, TERMS AND DEFINITIONS, ZONING AND EVALUATION OF ENERGY SOURCES
DIN V 18599-10:2016-10 ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 10: BOUNDARY CONDITIONS OF USE, CLIMATIC DATA
EN 1838:2013 Lighting applications - Emergency lighting

View more information
$354.19
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more