DIN EN 54-10:2002-05

Current

Current

The latest, up-to-date edition.

FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS

Available format(s)

Hardcopy , PDF

Published date

01-01-2002

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
  4.1 Compliance
  4.2 Classification
  4.3 Individual alarm indication
  4.4 Connection of ancillary devices
  4.5 Monitoring of detachable detectors
  4.6 Manufacturer's adjustments
  4.7 On-site sensitivity adjustment
  4.8 Data
  4.9 Additional requirements for software controlled
       detectors
       4.9.1 General
       4.9.2 Software documentation
       4.9.3 Software design
       4.9.4 The storage of programs and data
5 Tests
  5.1 General
       5.1.1 Atmospheric conditions for tests
       5.1.2 Operating conditions for tests
       5.1.3 Mounting arrangements
       5.1.4 Tolerances
       5.1.5 Determination of response point
       5.1.6 Test procedure
       5.1.7 Reduced functional tests
       5.1.8 Provision for tests
       5.1.9 Test schedule
  5.2 Reproducibility
       5.2.1 Object
       5.2.2 Test procedure
       5.2.3 Requirements
  5.3 Repeatability
       5.3.1 Object
       5.3.2 Test procedure
       5.3.3 Requirements
  5.4 Directional dependence
       5.4.1 Object
       5.4.2 Test procedure
       5.4.3 Requirements
  5.5 Fire sensitivity
       5.5.1 Object
       5.5.2 Test procedure
       5.5.3 Classification
       5.5.4 Requirements
  5.6 Dazzling (operational)
       5.6.1 Object
       5.6.2 Test procedure and apparatus
       5.6.3 Requirements
  5.7 Dry heat (operational)
       5.7.1 Object
       5.7.2 Test procedure and apparatus
       5.7.3 Requirements
  5.8 Cold (operational)
       5.8.1 Object
       5.8.2 Test procedure and apparatus
       5.8.3 Requirements
  5.9 Damp heat, cyclic (operational)
       5.9.1 Object
       5.9.2 Test procedure and apparatus
       5.9.3 Requirements
  5.10 Damp heat, steady state (endurance)
       5.10.1 Object
       5.10.2 Test procedure and apparatus
       5.10.3 Requirements
  5.11 Sulfur dioxide (SO[2]) corrosion (endurance)
       5.11.1 Object
       5.11.2 Test procedure and apparatus
       5.11.3 Requirements
  5.12 Shock (operational)
       5.12.1 Object
       5.12.2 Test procedure and apparatus
       5.12.3 Requirements
  5.13 Impact (operational)
       5.13.1 Object
       5.13.2 Test procedure and apparatus
       5.13.3 Requirements
  5.14 Vibration, sinusoidal, (operational)
       5.14.1 Object
       5.14.2 Test procedure and apparatus
       5.14.3 Requirements
  5.15 Vibration, sinusoidal (endurance)
       5.15.1 Object
       5.15.2 Test procedure and apparatus
       5.15.3 Requirements
  5.16 Variation in supply parameters (operational)
       5.16.1 Object
       5.16.2 Test procedure
       5.16.3 Requirements
  5.17 Electromagnetic Compatibility (EMC), Immunity
       tests (operational)
       5.17.1 Object
       5.17.2 Test procedure and apparatus
       5.17.3 Requirements
6 Marking
Annex A (normative) Annex A Apparatus for response point
        determination
        A.1 Optical bench
        A.2 Radiation source
        A.3 Shutter
        A.4 Modulator
        A.5 Radiometer
Annex B (informative) Example of a methane burner
Annex C (normative) Test fires
        C.1 Methylated spirit fire
Annex D (normative) Apparatus for dazzling test
Annex E (normative) Apparatus for impact test

Gives requirements, test methods and performance criteria for point-type, resetttable flame detectors that operate using radiation from a flame for use in fire detection systems installed in buildings.

DocumentType
Standard
Pages
38
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Current

ISO 209-1:1989 Wrought aluminium and aluminium alloys Chemical composition and forms of products Part 1: Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-56:1988 Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
$208.12
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.