DIN V 18599-4:2016-10
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
ENERGY EFFICIENCY OF BUILDINGS - CALCULATION OF THE NET, FINAL AND PRIMARY ENERGY DEMAND FOR HEATING, COOLING, VENTILATION, DOMESTIC HOT WATER AND LIGHTING - PART 4: NET AND FINAL ENERGY DEMAND FOR LIGHTING
Hardcopy , PDF
07-03-2021
German
01-01-2016
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions, symbols and units
3.1 Terms and definitions
3.2 Symbols, units and subscripts
3.2.1 Symbols and units
3.2.2 Subscripts
4 Relationship between the parts of the DIN V 18599 series of
prestandards
4.1 Input parameters from other parts of the DIN V 18599 series
of prestandards
4.2 Output parameters for other parts of the DIN V 18599 series
of prestandards
5 Calculations
5.1 Principle of the balance calculations
5.2 Subdivision of a building zone
5.2.1 Subdivision into evaluation areas
5.2.2 Daylight area
5.3 Operating times
5.4 Artificial lighting
5.4.1 Tabular method
5.4.2 Simplified utilization factor method
5.4.3 Detailed engineering planning
5.4.4 Determination of the specific electrical evaluation
power in existing buildings
5.5 Daylight
5.5.1 Annual daylight supply with vertical facades
5.5.2 Annual daylight supply through rooflights
5.5.3 Daylight-responsive control systems
5.5.4 Monthly evaluation method
5.6 Occupancy (presence)
Annex A (normative) Reduction factor k[A] to take into account
the relative proportion of the area needed for the
visual task
A.1 General
A.2 Detailed calculation of C[TL,Vers,Sa,j]
A.3 Examples of the electrical evaluation power of various
illumination solutions
A.3.1 General
A.3.2 Personal offices (single occupant)
A.3.3 Office for two occupants
A.3.4 Workgroup offices
A.3.5 Call centres (landscaped offices)
A.3.6 Corridors
A.3.7 Production hall
A.4 Example: Determination of the daylight supply factor
C[TL,Vers,j] for a space with rooflights
A.4.1 General
A.4.2 Determination of the electrical evaluation power
A.4.3 Determination of the daylight supply factor
C[TL,Vers]
A.4.4 Determination of the annual and monthly energy
use for lighting
Bibliography
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.