Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DR 99468 CP

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Decorative gas log and other fuel effect appliances

Superseded date

30-06-2017

Published date

03-09-1999

1 - DR 99468 CP DRAFT AGA STANDARD
2 - INTRODUCTION
3 - RECOMMENDED CHANGES FORM
5 - TITLE PAGE
6 - PREFACE
7 - CONTENTS
11 - GLOSSARY OF TERMS
23 - SECTION 1 : SCOPE
24 - SECTION 2 : DESIGN AND CONSTRUCTION
24 - 2.1 GENERAL
26 - 2.2 MATERIALS AND STANDARDS
28 - 2.3 ELECTRICAL SYSTEMS
28 - 2.4 INSTALLATION REQUIREMENTS
28 - 2.5 MAINTENANCE REQUIREMENTS
30 - 2.6 PRESSURE REGULATORS
30 - 2.7 GAS CONTROLS AND SAFETY SHUT-OFF SYSTEMS
31 - 2.8 COMBUSTION AIR SUPPLY AND CONTROLS
31 - 2.9 IGNITION, PILOTS AND MAIN BURNERS
32 - 2.10 FLUEING REQUIREMENTS
33 - 2.11 MARKINGS
36 - 2.12 INSTRUCTIONS
38 - SECTION 3 : PRELIMINARY TESTS – LINE GASES
38 - 3.1 GENERAL REQUIREMENTS
39 - 3.2 PREPARATION FOR TESTING
40 - 3.3 PRIMARY GUARDS
40 - 3.4 GAS LEAKAGE
40 - 3.5 GAS CONSUMPTION
40 - 3.6 GAS PRESSURE REGULATORS
40 - 3.7 IGNITION AND SAFETY SHUT- OFF SYSTEMS
44 - SECTION 4 : LIMIT GAS TESTS
52 - SECTION 5 : PERFORMANCE TESTS
52 - 5.1 FLUE OPERATION
52 - 5.2 FLUE GAS TEMPERATURES
52 - 5.3 NOISE OF OPERATION
52 - 5.4 CONDENSATION
52 - 5.5 COMBUSTION AIR SUPPLY
53 - 5.6 SAFETY SHUT- DOWN
53 - 5.7 TEMPERATURE HAZARDS
55 - 5.8 HEAT RESISTANCE
55 - 5.9 VITIATION AND EMISSIONS TESTS
56 - 5.10 LINTING TESTS
56 - 5.11 STRENGTH AND STABILITY
56 - 5.12 ROOM SEALED APPLIANCES
57 - 5.13 RAIN TEST
57 - 5.14 SPECIFICATIONS
58 - SECTION 6 : METHODS OF TEST
58 - M.O.T. 2.7.4 & 2. 11 – 99 MARKINGS AND LABELS
60 - M.O.T. 3.4.1 – 99 GAS LEAKAGE
61 - M.O.T. 3.5.1/ 2 – 99 GAS CONSUMPTION
63 - M.O.T. 3.6.1 – 99 GAS PRESSURE REGULATOR PERFORMANCE
65 - M.O.T. 3.7.1/ 3 – 99 IGNITION - AERATED PILOTS
67 - M.O.T. 3.7.2/ 3 – 99 IGNITION OF A BURNER PROTECTED BY A FLAME SAFEGUARD SYSTEM
69 - M.O.T. 3.7.4 – 99 IGNITION - OPENING OF FLAME SAFEGUARD SYSTEM
70 - M.O.T. 3.7.13 – 99 OPERATION OF SAFETY SHUT-OFF SYSTEM
72 - M.O.T. 3.7.15 (c)/ 3.7.18 (c) – 99 START FLAME ESTABLISHMENT PERIOD DELAYED IGNITION TESTS
74 - M.O.T. 4.1.2 – 99 DETERMINATION OF CO/ CO2 RATIO OF COMBUSTION PRODUCTS - REDUCED GAS INLET PRESSURE
76 - M.O.T. 4.1.3 – 99 DETERMINATION OF CO/ CO2 RATIO OF COMBUSTION PRODUCTS - OVERLOAD CONDITION
78 - M.O.T. 4.1.4 – 99 DETERMINATION OF CO/ CO2 RATIO OF COMBUSTION PRODUCTS - PERMANENT PILOTS
80 - M.O.T. 4.1.5 – 99 FLAME ABNORMALITY
82 - M.O.T. 4.1.6 – 99 IGNITION TESTS
84 - M.O.T. 4.1.7 – 99 DELAYED IGNITION TEST
86 - M.O.T. 4.1.8 – 99 FLAME STABILITY TO DRAUGHT
88 - M.O.T. 4.1.11 – 99 PILOT FLAMES – IGNITION AND STABILITY
91 - M.O.T. 4.1.12 – 99 EFFECT OF APPLIANCE DOOR OPERATION ON BURNER STABILITY
92 - M.O.T. 4.1.13 – 99 BURNER OPERATION - UNBURNT GAS SPILLAGE FROM BURNER SYSTEM
94 - M.O.T. 4.1.15 – 99 CASE PRESSURE TEST
96 - M.O.T. 4.1.16 – 99 SOOTING TEST - LUMINOUS EFFECT BURNERS
98 - M.O.T. 5.1.1 – 99 FLUE OPERATION - SPILLAGE TEST
101 - M.O.T. 5.1.2 – 99 DETERMINATION OF CO/ CO2 RATIO OF COMBUSTION PRODUCTS UNDER CONDITIONS OF FLUE BLOCKAGE, DOWNDRAUGHT OR UPDRAUGHT
103 - M.O.T. 5.2.1 – 99 FLUE GAS TEMPERATURE TEST
104 - M.O.T. 5.5.1/ 2/3 – 99 FLAME ABNORMALITY ON PROGRESSIVE AIR SUPPLY RESTRICTION
105 - M.O.T. 5.6.1/ 2 AND 2. 3.1 – 99 SAFE PERFORMANCE WITH ELECTRICITY SUPPLY VARIATION
107 - M.O.T. 5.7 – 99 TEMPERATURE HAZARDS
111 - M.O.T. 5.7.10 – 99 TEMPERATURE HAZARDS - ELECTRIC MOTORS
114 - M.O.T. 5.8.1 – 99 HEAT RESISTANCE
116 - M.O.T. 5.8.2 – 99 HEAT RESISTANCE - LIGHT BACK CONDITION
117 - M.O.T. 5.9.1 – 99 SAFETY SYSTEM TEST
120 - M.O.T. 5.9.2 – 99 DETERMINATION OF CO/ CO2 RATIO OF COMBUSTION PRODUCTS UNDER CONDITIONS OF NORMAL OPERATION
122 - M.O.T. 5.10.1/2 – 99 LINTING TEST
125 - M.O.T. 5.11.1 – 99 FLOOR LOADING TEST
126 - M.O.T. 5.11.2 – 99 STRENGTH - LOADING TEST
128 - M.O.T. 5.12 – 99 ROOM SEALED APPLIANCES
130 - M.O.T. 5.13.1 – 99 RAIN RESISTANCE OF FLUE TERMINALS OF ROOM SEALED APPLIANCES
132 - FIGURES
132 - FIGURE 1 STANDARD TOOL KIT TO BE USED IN THE EVALUATION OF SERVICEABILITY
133 - FIGURE 2 DEW PLATE
134 - FIGURE 3 GAS APPLIANCE WARNING LABEL
135 - FIGURE 4 BUBBLE LEAK DETECTOR
136 - FIGURE 5 TABLES FOR VALUES OF FACTOR A AND B
137 - FIGURE 6 FLUE GAS SAMPLING HOOD – RECTANGULAR
138 - FIGURE 7 FLUE GAS SAMPLING HOOD – CIRCULAR
139 - FIGURE 8 FLUE GAS SAMPLING HOOD PROBE
140 - FIGURE 9 SPILLAGE TEST RIG
141 - FIGURE 10 CONNECTION DIAGRAM FOR TEMPERATURES OF ELECTRIC MOTOR WINDINGS
142 - FIGURE 11 RAIN TEST SPRAY HEAD PIPE RACK
143 - FIGURE 12 DETAIL OF RAIN TEST SPRAY HEAD ASSEMBLY
144 - APPENDICES
144 - APPENDIX A GUIDELINES FOR SERVICING INSTRUCTIONS
145 - APPENDIX B FAULT FINDING CHART
146 - APPENDIX C MAINTENANCE SCHEDULE
147 - APPENDIX D MINIMUM INSTALLATION SPECIFICATIONS AND INSTALLATION REQUIREMENTS FOR DOMESTIC GAS APPLIANCES
149 - APPENDIX E WRITTEN APPLIANCE SPECIFICATIONS
152 - APPENDIX F METER VOLUME CORRECTION FACTORS
154 - APPENDIX G FLUE GAS SAMPLING AND TEMPERATURE MEASUREMENT
155 - FIGURE G1 TEST POINTS FOR CIRCULAR FLUES
156 - FIGURE G2 TEST POINTS FOR RECTANGULAR FLUES
157 - FIGURE G3 POSITIONS OF FLUE GAS SAMPLING PROBE FOR SPIGOTS -VERTICAL
158 - FIGURE G4 POSITIONS OF FLUE GAS SAMPLING PROBE FOR SPIGOTS -HORIZONTAL
159 - FIGURE G5 BALANCED FLUE APPLIANCES
160 - APPENDIX H FLUE SAMPLING METHOD FOR SMALL FLUES
161 - FIGURE H1 DETAILS OF SAMPLING PROBES FOR CIRCULAR AND RECTANGULAR FLUES LESS THAN 50 mm DIAMETER OR SQUARE
162 - FIGURE H2 SAMPLING PROBE POSITIONS – CIRCULAR FLUES LESS THAN 50 mm DIAMETER
163 - FIGURE H3 SAMPLING PROBE POSITIONS – RECTANGULAR FLUES LESS THAN 2500 mm2 CROSS SECTIONAL AREA

Proposed as the replacement for the Australian Gas Association Standard AG 108-1993, Approval Requirements for Domestic Decorative Gas Log Fires. It is the result of a comprehensive revision of the 1993 Standard. It provides uniform minimum requirements for the safe design and performance of decorative gas log and other fuel effect appliances. Neither the "Individual Certification Check List" nor the "Appliance Test Report Sheets" are included in this draft. They will, however, be published in due course.

CommentClosesDate
29-10-1999
Committee
AG-001
DocumentType
Draft
PublisherName
Standards Australia
Status
Superseded
SupersededBy

Revision of AG 108-1993. To be AS 4558/AG 108

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more