Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 13125:2001

Current
Current

The latest, up-to-date edition.

Shutters and blinds - Additional thermal resistance - Allocation of a class of air permeability to a product
Published date

25-04-2001

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Shutters - Allocation of air permeability classes
   4.1 Criteria for classes allocation
   4.2 Minimum classes admitted without assessment
   4.3 Conditions of allocation of class 5
5 External blinds, internal blinds, blinds incorporated
   into the glazing - Allocation of air permeability
   classes
   5.1 Criteria for class allocation
   5.2 External blinds
   5.3 Internal blinds and blinds incorporated into the
       glazing
   5.4 Blinds with one side with low emissivity coating
6 Presence of a top box (case of roller shutter)
   6.1 Top box independent of window frame (roller
       shutter for subsequent installation for instance)
   6.2 Top box installed inside the masonry or with the
       framing
ANNEX A (normative) Thermal resistance of PVC profiles
        curtain
ANNEX B (informative) Usual values of peripheral gaps
        for interior blinds and blinds incorporated
        into the glazing

This European Standard specifies the classification criteria of shutters and internal and external blinds in relation with their air permeability for the calculation of additional thermal resistance given by these products according to EN ISO 10077-1.This standard applies to shutters and blinds fitted to a window, a French window or a curtain walling in such a way that in extended and closed position they inclose an air layer of thickness roughly constant between 15 mm and 300 mm (shutters and blinds parallel to the window or to the façade).This standard applies to the following shutters and blinds :- Shutters : roller shutter, external venetien blind, wing shutter, sliding panel shutter, venetian shutter, concertina shutter, flat-closing concertina shutter ;- External blinds : vertical awning, facade awning, conservatory awning ;- Internal blinds : venetian blind, roller blind, vertical blind, pleated blind ; - Blinds incorporated into glazing.

Committee
CEN/TC 33
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
UNI EN 13125 : 2003 Identical
BS EN 13125:2001 Identical
NBN EN 13125 : 2001 Identical
PN EN 13125 : 2005 Identical
SN EN 13125 : 2001 Identical
UNE-EN 13125:2001 Identical
NEN EN 13125 : 2001 Identical
NS EN 13125 : 1ED 2001 Identical
NF EN 13125 : 2002 Identical
I.S. EN 13125:2001 Identical
DIN EN 13125:2001-10 Identical

14/30302455 DC : 0 BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
06/30156314 DC : 0 BS EN 13120 - INTERNAL BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
BS EN 13120 : 2009 INTERNAL BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
DIN EN 13561:2015-08 EXTERNAL BLINDS AND AWNINGS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
EN 13561:2015/AC:2016 EXTERNAL BLINDS AND AWNINGS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
11/30241848 DC : 0 BS EN 13561 - EXTERNAL BLINDS AND AWNINGS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
14/30302452 DC : 0 BS EN 13561 - EXTERNAL BLINDS AND AWNINGS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
PREN 13659 : DRAFT 2014 SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
I.S. EN 13659:2015 SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
EN 14501:2005 Blinds and shutters - Thermal and visual comfort - Performance characteristics and classification
I.S. EN 13120:2009 INTERNAL BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
I.S. EN 13561:2015 EXTERNAL BLINDS AND AWNINGS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
DIN EN 13120:2014-09 INTERNAL BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
DIN EN 14501 E : 2006 BLINDS AND SHUTTERS - THERMAL AND VISUAL COMFORT - PERFORMANCE CHARACTERISTICS AND CLASSIFICATION
UNI EN 13120 : 2014 INTERNAL BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
11/30241851 DC : 0 BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
I.S. EN ISO 10077-1:2017 THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 1: GENERAL (ISO 10077-1:2017)
BS EN 14501:2005 Blinds and shutters. Thermal and visual comfort. Performance characteristics and classification
UNE-EN 13659:2016 Shutters and external venetian blinds - Performance requirements including safety
BS EN 13561:2015 External blinds and awnings. Performance requirements including safety
EN ISO 10077-1:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02)
EN 13659:2015 Shutters and external venetian blinds - Performance requirements including safety
PREN 13561 : DRAFT 2014 EXTERNAL BLINDS AND AWNINGS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
BS EN 13120:2009+A1:2014 Internal blinds. Performance requirements including safety
DIN EN 13659:2015-07 SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
BS EN 13659:2015 Shutters and external venetian blinds. Performance requirements including safety
I.S. EN 14501:2005 BLINDS AND SHUTTERS - THERMAL AND VISUAL COMFORT - PERFORMANCE CHARACTERISTICS AND CLASSIFICATION
DIN EN 14501:2006-02 Blinds and shutters - Thermal and visual comfort - Performance characteristics and classification

EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
EN 12835:2000 Airtight shutters - Air permeability test
ISO 10211-1:1995 Thermal bridges in building construction Heat flows and surface temperatures Part 1: General calculation methods
EN ISO 6946:2017 Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12)
ISO 8302:1991 Thermal insulation — Determination of steady-state thermal resistance and related properties — Guarded hot plate apparatus
PREN ISO 10077-2 : DRAFT 2009 THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES
EN ISO 10211-1 : 95 COR 2002 THERMAL BRIDGES IN BUILDING CONSTRUCTION - CALCULATION OF HEAT FLOWS AND SURFACE TEMPERATURES - PART 1: GENERAL METHODS
PREN 12216 : DRAFT 2016 SHUTTERS, EXTERNAL BLINDS, INTERNAL BLINDS - TERMINOLOGY, GLOSSARY AND DEFINITIONS
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
EN ISO 10077-1:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more