Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 13241:2003+A2:2016

Current
Current

The latest, up-to-date edition.

Industrial, commercial, garage doors and gates - Product standard, performance characteristics
Published date

21-09-2016

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Marking and labelling
6 Evaluation of conformity
Annex A (informative) - Form for designation and classification
        of performances
Annex B (normative) - Procedure for the determination of values
        for thermal resistance
Annex C (informative) - Safety factors to be considered in door
        design in respect of their resistance to wind load
Annex ZA (informative) - Relationship of this European Standard
         with the Construction Products Directive
Annex ZB (informative) - Relationship between this European
         Standard and the Essential Requirements of EU Directive
         2006/42/EC
Annex ZC (informative) - Relationship between this European
         Standard and the Essential Requirements of EU Directive
         2004/108/EC
Bibliography

1.1GeneralThis European Standard specifies the safety and performance requirements, except resistance to fire and smoke control characteristics, for industrial, commercial, garage doors and gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.Fire resisting and/or smoke control characteristics for industrial, commercial, garage doors and gates are covered by EN 16034.This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard.These devices can be manually or power operated.This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000 6 3.1.2ExclusionsThis European Standard does not apply to the following which are intended for a different use:-lock gates and dock gates;-doors on lifts;-doors on vehicles;-armoured doors;-doors mainly for the retention of animals;-theatre textile curtains;-horizontally moving power operated doors mainly intended for pedestrian use in accordance with EN 16361;-revolving doors of any size;-railway barriers;-barriers used solely for vehicles.This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition.This European Standard does not contain any specific requirement for doors which are moving because of energy stored by dedicated means from human power such as manually tensioned springs.This European Standard does not contain any specific requirements for doors on escape routes. The ability to open the door leaf safely and easily cannot normally be achieved by industrial, commercial and garage doors due to size, weight and/or mode of operation.The noise emission of powered doors and gates is not considered to be a relevant hazard. Therefore this European Standard does not contain any specific requirements on noise in relation to the Machinery Directive.1.3Specific applicationsThis European Standard should also apply to power operated doors which have been created by the addition of power operation to an installed manual door in respect of the relevant requirements. Annex ZA does not apply to this kind of door.It also identifies requirements and classes of performance for additional characteristics considered to be of importance to the trade.When a door is part of the load carrying structure of the building the requirements of this European Standard can apply on a voluntary basis in addition to the requirements for the load carrying structure, which are not dealt with in this European Standard. Annex ZA does not apply for this kind of doors.

Committee
CEN/TC 33
DevelopmentNote
2003 + A2 2016 Edition Supersedes and Redesignates EN 13241-1 as EN 13241 and incorporates AMD 2 2016. (10/2016)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

I.S. EN 14351-1:2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS
I.S. EN 12604:2017 INDUSTRIAL, COMMERCIAL AND GARAGE DOORS AND GATES - MECHANICAL ASPECTS - REQUIREMENTS AND TEST METHODS
EN 12604:2017 Industrial, commercial and garage doors and gates - Mechanical aspects - Requirements and test methods
UNE-EN 12604:2018 Industrial, commercial and garage doors and gates - Mechanical aspects - Requirements and test methods
BS EN 14351-1 : 2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS
EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
UNE-EN 14351-1:2006 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics

EN 12489:2000 Industrial, commercial and garage doors and gates - Resistance to water penetration - Test method
EN 16361:2013+A1:2016 Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation
EN 418 : 1992 SAFETY OF MACHINERY - EMERGENCY STOP EQUIPMENT, FUNCTIONAL ASPECTS - PRINCIPLES FOR DESIGN
EN 1037:1995+A1:2008 Safety of machinery - Prevention of unexpected start-up
EN 61000-6-3:2007/A1:2011/AC:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010)
EN 12605:2000 Industrial, commercial and garage doors and gates - Mechanical aspects - Test methods
EN 12433-1:1999 Industrial, commercial and garage doors and gates - Terminology - Part 1: Types of doors
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 60204-1:2016 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
EN 12635:2002+A1:2008 Industrial, commercial and garage doors and gates - Installation and use
EN 12978:2003+A1:2009 Industrial, commercial and garage doors and gates - Safety devices for power operated doors and gates - Requirements and test methods
ISO 140-3:1995 Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3: Laboratory measurements of airborne sound insulation of building elements
EN 12428:2013 Industrial, commercial and garage doors - Thermal transmittance - Requirements for the calculation
EN 12426:2000 Industrial, commercial and garage doors and gates - Air permeability - Classification
EN 12445:2000 Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Test methods
IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
ISO 12567-1:2010 Thermal performance of windows and doors Determination of thermal transmittance by the hot-box method Part 1: Complete windows and doors
EN 12433-2:1999 Industrial, commercial and garage doors and gates - Terminology - Part 2: Parts of doors
EN ISO 140-3:1995/A1:2004 ACOUSTICS - MEASUREMENT OF SOUND INSULATION IN BUILDINGS AND OF BUILDING ELEMENTS - PART 3: LABORATORY MEASUREMENTS OF AIRBORNE SOUND INSULATION OF BUILDING ELEMENTS
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
EN 12444:2000 Industrial, commercial and garage doors and gates - Resistance to wind load - Testing and calculation
ENV 1991-2-4 : 1995 EUROCODE 1: BASIS OF DESIGN AND ACTIONS ON STRUCTURES - ACTIONS ON STRUCTURES - WIND ACTIONS (TOGETHER WITH UNITED KINGDOM NATIONAL APPLICATION DOCUMENT)
EN 12427:2000 Industrial, commercial and garage doors and gates - Air permeability - Test method
ISO 717-1:2013 Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation
EN 16034:2014 Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics
EN 12424:2000 Industrial, commercial and garage doors and gates - Resistance to wind load - Classification
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
EN 12425:2000 Industrial, commercial and garage doors and gates - Resistance to water penetration - Classification
EN 12604:2017 Industrial, commercial and garage doors and gates - Mechanical aspects - Requirements and test methods
EN 60204-1 : 2006 COR 2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more