Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 13598-1:2010

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings including shallow inspection chambers
Superseded date

28-02-2022

Published date

08-12-2010

Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Material
5 General characteristics
6 Geometrical characteristics
7 Types of ancillary fittings
8 Physical characteristics
9 Mechanical characteristics
10 Performance requirements
11 Marking
Annex A (normative) - Reformulated material characteristics
        used for shallow inspection chambers
Annex B (normative) - Testing sequence and techniques to be
        used when testing saddles
Bibliography

This European Standard specifies the definitions and requirements for ancillary fittings of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), and polyethylene (PE) intended to be used in non-pressure underground drainage and sewerage systems, conforming to EN 476:a)outside the building structure (application area code "U"), reflected in the marking of products by "U", andb)both buried in ground within the building structure (application area code "D") and outside the building structure (application area code "U"), reflected in the marking of products by "UD".It also specifies the test parameters for the test methods referred in this standard.The ancillary fittings covered by this standard are the following:-sealed access fittings;-rodding point covers;-rodding tees;-mechanical saddles;-inspection chambers for shallow non-roadway applications to a maximum depth of 1,25 m.NOTE 1Inspection chambers as defined in 6.1.3 of EN 476:1997 have a riser with a DN/ID less than 800 mm.NOTE 2Deep inspection chambers and manholes for application area U are specified in Part 2 of this standard.The fittings can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated from components made to other standards.The jointing can be with:-elastomeric ring seal joint;-cemented joint for PVC-U;-welded joint for PP and PE.NOTE 3Pipes, fittings and other components conforming to any of the plastics products standards listed in Clause 2 can be used with ancillary fittings conforming to this standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 5.

Committee
CEN/TC 155
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded

DIN EN 124-6:2015-09 GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 6: GULLY TOPS AND MANHOLE TOPS MADE OF POLYPROPYLENE (PP), POLYETHYLENE (PE) OR UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U)
DIN EN 13598-2:2016-09 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR MANHOLES AND INSPECTION CHAMBERS
UNE-EN 13598-2:2017 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for manholes and inspection chambers
PREN 1401-1 : DRAFT 2018 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEMS
CEN/TS 13598-3:2012 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride)(PVC-U), polypropylene (PP) and polyethylene (PE) - Part 3: Guidance for assessment of conformity
EN 124-6:2015 Gully tops and manhole tops for vehicular and pedestrian areas - Part 6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U)
EN 12050-1:2015 Wastewater lifting plants for buildings and sites - Part 1: Lifting plants for wastewater containing faecal matter
PD CEN/TS 13598-3:2012 Plastics piping systems for non-pressure underground drainage and sewerage. Unplasticized poly(vinyl chloride)(PVC-U), polypropylene (PP) and polyethylene (PE) Guidance for assessment of conformity
05/30132762 DC : 0 PREN 15229 - PLASTICS PIPING SYSTEMS - PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - PERFORMANCE REQUIREMENTS FOR THERMOPLASTICS MANHOLES AND INSPECTION CHAMBERS
I.S. EN 124-6:2015 GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 6: GULLY TOPS AND MANHOLE TOPS MADE OF POLYPROPYLENE (PP), POLYETHYLENE (PE) OR UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U)
18/30371677 DC : DRAFT MAY 2018 BS EN 1401-1 - PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES, FITTINGS AND THE SYSTEMS
I.S. EN 12050-1:2015 WASTEWATER LIFTING PLANTS FOR BUILDINGS AND SITES - PART 1: LIFTING PLANTS FOR WASTEWATER CONTAINING FAECAL MATTER
DIN EN 13598-2 E : 2016 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR MANHOLES AND INSPECTION CHAMBERS
DIN EN 124-6 E : 2015 GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 6: GULLY TOPS AND MANHOLE TOPS MADE OF POLYPROPYLENE (PP), POLYETHYLENE (PE) OR UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U)
S.R. CEN/TS 13598-3:2012 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE)(PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: GUIDANCE FOR ASSESSMENT OF CONFORMITY
UNE-EN 124-6:2015 Gully tops and manhole tops for vehicular and pedestrian areas - Part 6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U)
DIN EN 12050-1:2015-05 WASTEWATER LIFTING PLANTS FOR BUILDINGS AND SITES - PART 1: LIFTING PLANTS FOR WASTEWATER CONTAINING FAECAL MATTER
UNI CEN/TS 13598-3 : 2012 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY
BS EN 12050-1:2015 Wastewater lifting plants for buildings and sites Lifting plants for wastewater containing faecal matter
EN 13598-2:2016 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for manholes and inspection chambers
UNE-EN 12050-1:2015 Wastewater lifting plants for buildings and sites - Part 1: Lifting plants for wastewater containing faecal matter
BS EN 124-6:2015 Gully tops and manhole tops for vehicular and pedestrian areas Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U)
I.S. EN 13598-2:2016 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR MANHOLES AND INSPECTION CHAMBERS
BS EN 13598-2:2009 Plastics piping systems for non-pressure underground drainage and sewerage. Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) Specifications for manholes and inspection chambers in traffic areas and deep underground installations

EN 1277:2003 Plastics piping systems - Thermoplastics piping systems for buried non-pressure applications - Test methods for leaktightness of elastomeric sealing ring type joints
EN 295-3:2012 Vitrified clay pipe systems for drains and sewers - Part 3: Test methods
ISO 580:2005 Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating
EN ISO 3126:2005 Plastics piping systems - Plastics components - Determination of dimensions (ISO 3126:2005)
EN 681-4:2000/A2:2005 ELASTOMERIC SEALS - MATERIALS REQUIREMENTS FOR PIPE JOINT SEALS USED IN WATER AND DRAINAGE APPLICATIONS - PART 4: CAST POLYURETHANE SEALING ELEMENTS
EN 681-1:1996/A3:2005 ELASTOMERIC SEALS - MATERIALS REQUIREMENTS FOR PIPE JOINT SEALS USED IN WATER AND DRAINAGE APPLICATIONS - PART 1: VULCANIZED RUBBER
EN 728:1997 Plastics piping and ducting systems - Polyolefin pipes and fittings - Determination of oxidation induction time
EN ISO 1043-1:2011/A1:2016 PLASTICS - SYMBOLS AND ABBREVIATED TERMS - PART 1: BASIC POLYMER AND THEIR SPECIAL CHARACTERISTICS (ISO 1043-1:2011/AMD 1:2016)
ISO 265-1:1988 Pipes and fittings of plastics materials Fittings for domestic and industrial waste pipes Basic dimensions: Metric series Part 1: Unplasticized poly(vinyl chloride) (PVC-U)
EN 681-3:2000/A2:2005 ELASTOMERIC SEALS - MATERIALS REQUIREMENTS FOR PIPE JOINT SEALS USED IN WATER AND DRAINAGE APPLICATIONS - PART 3: CELLULAR MATERIALS OF VULCANIZED RUBBER
EN 1055:1996 Plastics piping systems - Thermoplastics piping systems for soil and waste discharge inside buildings - Test method for resistance to elevated temperature cycling
EN 681-2:2000/A2:2005 ELASTOMERIC SEALS - MATERIALS REQUIREMENTS FOR PIPE JOINT SEALS USED IN WATER AND DRAINAGE APPLICATIONS - PART 2: THERMOPLASTIC ELASTOMERS
EN 14680:2015 Adhesives for non-pressure thermoplastics piping systems - Specifications
EN 922:1994 Plastics piping and ducting systems - Pipes and fittings of unplasticized poly(vinyl chloride) (PVC-U) - Specimen preparation for determination of the viscosity number and calculation of the K-value
EN 1253-2:2015 GULLIES FOR BUILDINGS - PART 2: ROOF DRAINS AND FLOOR GULLIES WITHOUT TRAP
ISO 3126:2005 Plastics piping systems Plastics components Determination of dimensions
EN 476:2011 General requirements for components used in drains and sewers
EN 14982:2006+A1:2010 Plastics piping and ducting systems - Thermoplastics shafts or risers for inspection chambers and manholes - Determination of ring stiffness
EN 14758-1:2012 Plastics piping systems for non-pressure underground drainage and sewerage - Polypropylene with mineral modifiers (PP-MD) - Part 1: Specifications for pipes, fittings and the system
ISO 1183-1:2012 Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method
EN 12666-1:2005+A1:2011 Plastics piping systems for non-pressure underground drainage and sewerage - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system
ISO 1183-2:2004 Plastics Methods for determining the density of non-cellular plastics Part 2: Density gradient column method
EN ISO 580:2005 Plastics piping and ducting systems - Injection-moulded thermoplastics fittings - Methods for visually assessing the effects of heating (ISO 580:2005)
EN 1401-1:2009 Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system
EN 14830:2006 Thermoplastics inspection chamber and manhole bases - Test methods for buckling resistance
EN 1053:1995 Plastics piping systems - Thermoplastics piping systems for non-pressure applications - Test method for watertightness
EN ISO 1133:2005 PLASTICS - DETERMINATION OF THE MELT MASS-FLOW RATE (MFR) AND THE MELT VOLUME-FLOW RATE (MVR) OF THE THERMOPLASTICS
ISO 1043-1:2011 Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special characteristics
EN 1253-1:2015 GULLIES FOR BUILDINGS - PART 1: TRAPPED FLOOR GULLIES WITH A DEPTH WATER SEAL OF AT LEAST 50 MM
EN 1437:2002 Plastics piping systems - Piping systems for underground drainage and sewerage - Test method for resistance to combined temperature cycling and external loading
EN 12256:1998 Plastics piping systems - Thermoplastics fittings - Test method for mechanical strength or flexibility of fabricated fittings
ISO 1133:2005 Plastics Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics
EN ISO 1183-1:2012 Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1:2012)
EN ISO 1183-2:2004 PLASTICS - METHODS FOR DETERMINING THE DENSITY OF NON-CELLULAR PLASTICS - PART 2: DENSITY GRADIENT COLUMN METHOD

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more