Building hardware - Electrically controlled exit systems for use on escape routes - Requirements and test methods

Published date

10-06-2015

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and
  sampling methods
6 Assessment and verification
  of constancy of performance - AVCP
7 Classification and designation
8 Marking, labelling and packaging
Annex A (informative) - Information supplied
        with the product
Annex B (normative) - Test sequences with
        different samples
Annex C (informative) - Guidance for choosing
        relevant product standards for particular
        exit door applications
Annex D (informative) - Access levels, Installation
        and maintenance
Annex E (informative) - Functional diagrams
Annex F (informative) - Examples of configurations
        and description of exit systems
Annex ZA (informative) - Clauses of this
         European Standard addressing the
         provisions of the EU Construction
         Products Regulation

This European standard specifies requirements for the manufacture; performance and testing of electrically controlled exit systems, designed for use on escape routes. These systems consist of at least the following elements:- Initiating element for requesting the release of electrical locking element in order to exit;- Electrical locking element for securing an exit door;- Electrical controlling element for supplying, connecting and controlling electrical locking element and initiating element. In addition, these electrically controlled exit systems can include time delay and/or denied exit mode. This European Standard covers electrically controlled exit systems placed on the market as a complete unit (e.g. mortise lock, lever handle, keeper, initiating element, electrical locking element, electrical controlling element, etc.). The components are tested as a single product. This European Standard covers electrically controlled exit systems which are either manufactured and placed on the market in their entirety by one manufacturer or assembled from sub-assemblies produced by more than one manufacturer and subsequently placed on the market as a kit in a single transaction. The suitability of an electrically controlled exit system for use on fire/smoke resisting door assemblies is determined by fire performance tests conducted in addition to the performance tests required by this European Standard.

Committee
CEN/TC 33
DevelopmentNote
Supersedes PREN 13637. (06/2015)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
DIN EN 13637:2015-12 Identical
PN EN 13637 : 2015 Identical
UNI EN 13637 : 2015 Identical
SN EN 13637 : 2015 Identical
NF EN 13637 : 2015 Identical
NBN EN 13637 : 2015 Identical
I.S. EN 13637:2015 Identical
NEN EN 13637 : 2015 Identical
UNE-EN 13637:2016 Identical
NS EN 13637 : 2015 Identical
BS EN 13637:2015 Identical

BS EN 16034:2014 Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics
I.S. EN 16034:2014 PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS
PREN 1125 : DRAFT 2016 BUILD HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS
PREN 50518 : DRAFT 2016 MONITORING AND ALARM RECEIVING CENTRE
PREN 179 : DRAFT 2016 BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS
UNE-EN 16034:2015 Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics
DIN EN 16034:2014-12 PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS
16/30343246 DC : 0 BS EN 1125 - BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS
EN 16034:2014 Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics
16/30299842 DC : 0 BS EN 50518 - MONITORING AND ALARM RECEIVING CENTRE
16/30343249 DC : 0 BS EN 179 - BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS

ISO 7010:2011 Graphical symbols Safety colours and safety signs Registered safety signs
EN 60947-5-5 : 1997 AMD 2 2016 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-5: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTRICAL EMERGENCY STOP DEVICE WITH MECHANICAL LATCHING FUNCTION (IEC 60947-5-5:1997/A2:2016)
EN 1125:2008 Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
EN 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements
EN 61000-6-3:2007/A1:2011/AC:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010)
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
EN 1670:2007/AC:2008 BUILDING HARDWARE - CORROSION RESISTANCE - REQUIREMENTS AND TEST METHODS
EN 1634-3:2004/AC:2006 FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 3: SMOKE CONTROL TEST FOR DOOR AND SHUTTER ASSEMBLIES
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
IEC 60050-845:1987 International Electrotechnical Vocabulary (IEV) - Part 845: Lighting
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
EN 1634-2 : 2008 Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
EN ISO 7010 : 2012 AMD 7 2017 GRAPHICAL SYMBOLS - SAFETY COLOURS AND SAFETY SIGNS - REGISTERED SAFETY SIGNS (ISO 7010:2011/AMD 7:2016)
IEC 60947-5-5:1997+AMD1:2005+AMD2:2016 CSV Low-voltage switchgear and controlgear - Part 5-5: Control circuitdevices and switching elements - Electrical emergency stop device with mechanical latching function
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
EN 179:2008 Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more