View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Fire resistance tests for service installations - Part 3: Penetration seals
Superseded date

14-01-2022

Published date

25-02-2009

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
   5.1 Heating conditions
   5.2 Pressure conditions
6 Test specimen
   6.1 Size and distances
   6.2 Number
   6.3 Design
   6.4 Construction
   6.5 Verification
7 Installation of test specimen
   7.1 General
   7.2 Supporting construction
   7.3 Installation of service(s)
   7.4 Installation of penetration seal
   7.5 Multiple penetration seals in one test specimen
8 Conditioning
9 Application of instrumentation
   9.1 Thermocouples
   9.2 Integrity measurement
   9.3 Pressure
10 Test procedure
   10.1 General
   10.2 Integrity
   10.3 Other observations
11 Performance criteria
   11.1 Integrity
   11.2 Insulation
   11.3 Multiple penetrations
12 Test report
13 Field of direct application of test results
   13.1 Orientation
   13.2 Supporting construction
   13.3 Services
   13.4 Service support construction
   13.5 Seal size and distances
Annex A (normative) - Standard configuration for large cable
        penetration seals
        A.1 Structure of specimens
        A.2 Non-standard configuration
        A.3 Field of direct application
Annex B (normative) - Standard configuration for small cable
        penetration seals
        B.1 Structure of specimens
        B.2 Field of direct application
        B.3 Non-standard configuration
Annex C (normative) - Standard configuration and field of direct
        application for modular systems and cable boxes
        C.1 Modular Systems
        C.2 Cable boxes
        C.3 Non-standard configuration
Annex D (normative) - Specimen design and field of direct
        application for bus bars
        D.1 Structure of specimens
        D.2 Field of direct application
        D.3 Non-standard configuration
Annex E (normative) - Standard configuration and field of direct
        application for pipe penetration seals
        E.1 Standard configuration for penetration seals for
            pipes according to 6.3.2 a) - "metal pipes"
        E.2 Standard configuration for penetration seals for
            pipes according to 6.3.2 d) - "plastic pipes"
        E.3 Trunking and conduits
        E.4 Standard configuration for floor penetrations ending
            at floor level (e.g. floor drain)
Annex F (normative) - Standard configuration and field of direct
        application for large mixed penetration seals
        F.1 General
        F.2 Standard Mixed Module
        F.3 Standard configuration for combinations of
            type a) according to F.1.2
        F.4 Standard configuration for combinations of
            type b), c) and d) according to F.1.2
        F.5 Field of direct application
Annex G (normative) - Critical pipe/cable approach
        G.1 General
        G.2 Definition of "critical"
        G.3 Procedure selecting critical pipes from previous
            test data
        G.4 Procedure selecting critical cables from previous
            test data
Annex H (informative) - Explanatory notes
        H.1 General
        H.2 Notes on the scope and application of test results
        H.3 Notes on test conditions
        H.4 Notes on test construction
        H.5 Notes on test procedure
        H.6 Notes on test criteria
        H.7 Notes on validity of test results (field of
            application)
        H.8 Notes on test report
Bibliography

This Part of EN 1366 specifies a method of test and criteria for the evaluation (including field of application rules) of the ability of a penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service. Penetration seals used to seal gaps around chimneys, air ventilation systems, fire rated ventilation ducts, fire rated service ducts, shafts and smoke extraction ducts are excluded from this standard except for mixed penetration seals. The fire resistance of those services itself cannot be assessed with the methods described in this standard.Supporting constructions are used in this standard to represent separating elements such as walls or floors. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice.This European Standard is used in conjunction with EN 1363-1.The purpose of this test described in this standard is to assess:a)the effect of such penetrations on the integrity and insulation performance of the separating element concerned;b)the integrity and insulation performance of the penetration seal;c)the insulation performance of the penetrating service or services, and where necessary, the integrity failure of a service.No information can be implied by the test concerning the influence of the inclusion of such penetrations and sealing systems on the loadbearing capacity of the separating element.It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes. Such phenomena are only to be noted in describing the general behaviour of test specimens during the test.This test is not intended to supply any information on the ability of the penetration seal to withstand stress caused by movements or displacements of the penetrating services.

DevelopmentNote
Supersedes PREN 1366-3. (10/2005) To be read in conjunction with EN 1363-1. (03/2009)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
ONORM EN 1366-3 : 2009 Identical
BS EN 1366-3:2009 Identical
NF EN 1366-3 : 2012 Identical
NBN EN 1366-3 : 2009 Identical
UNE-EN 1366-3:2011 Identical
SN EN 1366-3 : 2009 Identical
DIN EN 1366-3:2009-07 Identical
UNI EN 1366-3 : 2009 Identical
I.S. EN 1366-3:2009 Identical
NS EN 1366-3 : 2009 Identical
NEN EN 1366-3 : 2009 Identical
PN EN 1366-3 : 2010 Identical

DIN EN 15882-3:2009-07 EXTENDED APPLICATIONS OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
I.S. EN 1996-1-2:2005 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN (INCLUDING IRISH NATIONAL ANNEX)
12/30254917 DC : DRAFT JAN 2012 BS EN 877 - CAST IRON PIPES AND FITTINGS, THEIR JOINTS AND ACCESSORIES FOR THE EVACUATION OF WATER FROM BUILDINGS - REQUIREMENTS, TEST METHODS AND QUALITY ASSURANCE
FM 4990 : 2009
99/540249 DC : DRAFT MAR 1999 PREN 13501-2 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS (EXCLUDING PRODUCTS FOR USE IN VENTILATION SYSTEMS)
17/30309558 DC : 0 BS IEC 60772 ED 2.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION SYSTEMS IMPORTANT TO SAFETY - ELECTRICAL PENETRATION ASSEMBLIES IN CONTAINMENT STRUCTURES
DIN EN 14304:2016-03 THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION
I.S. EN 50600-2-5:2016 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
17/30350914 DC : 0 BS EN 1047-2 - SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
UNE-EN 13501-2:2009 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
DIN EN 1996-1-2:2011-04 Eurocode 6: Design of masonry structures - Part 1-2: General rules - Structural fire design (includes Corrigendum AC:2010)
BS EN 877 : 1999 CAST IRON PIPES AND FITTINGS, THEIR JOINTS AND ACCESSORIES FOR THE EVACUATION OF WATER FROM BUILDINGS - REQUIREMENTS, TEST METHODS AND QUALITY ASSURANCE
I.S. EN 877:2000 CAST IRON PIPES AND FITTINGS, THEIR JOINTS AND ACCESSORIES FOR THE EVACUATION OF WATER FROM BUILDINGS - REQUIREMENTS, TEST METHODS AND QUALITY ASSURANCE
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
UNI EN 877 : 2007 CAST IRON PIPES AND FITTINGS, THEIR JOINTS AND ACCESSORIES FOR THE EVACUATION OF WATER FROM BUILDINGS - REQUIREMENTS, TEST METHODS AND QUALITY ASSURANCE
EN 877:1999/A1:2006/AC:2008 CAST IRON PIPES AND FITTINGS, THEIR JOINTS AND ACCESSORIES FOR THE EVACUATION OF WATER FROM BUILDINGS - REQUIREMENTS, TEST METHODS AND QUALITY ASSURANCE
EN 50600-2-5:2016 Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems
PREN 14304 : DRAFT 2015 THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION
EN 1366-5:2010 Fire resistance tests for service installations - Part 5: Service ducts and shafts
I.S. EN 14304:2015 THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION
BS EN 14304 : 2009 THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION
DIN EN 877:2010-01 Cast iron pipes and fittings, their joints and accessories for the evacuation of water from buildings - Requirements, test methods and quality assurance (includes Amendment A1:2006 and Corrigendum AC:2008)
I.S. EN 13501-2:2016 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
UNE-EN 1996-1-2:2011 Eurocode 6 - Design of masonry structures - Part 1-2: General rules - Structural fire design
DIN EN 14304 E : 2016 THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION
BS EN 15882-3:2009 Extended applications of results from fire resistance tests for service installations Penetration seals
15/30302476 DC : 0 BS EN 13501-2 - FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
BS EN 1366-5:2010 Fire resistance tests for service installations Service ducts and shafts
PREN 1047-2 : DRAFT 2017 SECURE STORAGE UNITS - CLASSIFICATION AND METHODS OF TEST FOR RESISTANCE TO FIRE - PART 2: DATA ROOMS AND DATA CONTAINER
I.S. ENV 1996-1-2:1995 EUROCODE 6: DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
UNI EN 1996-1-2 : 2005 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
15/30315090 DC : DRAFT MAY 2015 BS EN 14304 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION
04/30124508 DC : 0 EN 15080-12 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 12: PENETRATION SEALS
CEI EN 50600-2-5 : 2017 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
ISO/IEC TS 22237-6:2018 Information technology — Data centre facilities and infrastructures — Part 6: Security systems
UNI EN 15882-3 : 2009 EXTENDED APPLICATIONS OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
UNI EN 1366-5 : 2010 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 5: SERVICE DUCTS AND SHAFTS
I.S. EN 15882-3:2009 EXTENDED APPLICATIONS OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS
BS EN 13501-2 : 2007 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
ONORM EN 877 : 2008 CAST IRON PIPES AND FITTINGS, THEIR JOINTS AND ACCESSORIES FOR THE EVACUATION OF WATER FROM BUILDINGS - REQUIREMENTS, TEST METHODS AND QUALITY ASSURANCE
ENV 1996-1-2 : 1995 EUROCODE 6: DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
EN 14304:2015 Thermal insulation products for building equipment and industrial installations - Factory made flexible elastomeric foam (FEF) products - Specification
EN 15882-3:2009 Extended applications of results from fire resistance tests for service installations - Part 3: Penetration seals
EN 1996-1-2:2005/AC:2010 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
PREN 13501-2 : DRAFT 2015 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
DIN EN 1366-5:2010-06 Fire resistance tests for service installations - Part 5: Service ducts and shafts
07/30171469 DC : DRAFT DEC 2007 BS EN 15080-15 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 15: LINEAR JOINT SEALS
16/30324104 DC : 0 BS EN 1364-6 - FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 6: CAVITY BARRIERS
I.S. EN 1366-5:2010 FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 5: SERVICE DUCTS AND SHAFTS
BS EN 1996-1-2:2005 Eurocode 6. Design of masonry structures General rules. Structural fire design

EN 520:2004+A1:2009 Gypsum plasterboards - Definitions, requirements and test methods
EN 61386-21:2004/A11:2010 CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 21: PARTICULAR REQUIREMENTS - RIGID CONDUIT SYSTEMS
HD 21-3 : S3 AMD 2 2008 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - NON-SHEATHED CABLES FOR FIXED WIRING
EN 1566-1:1998 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Chlorinated poly(vinyl chloride) (PVC-C) - Part 1: Specifications for pipes, fittings and the system
EN 10305-6:2016 Steel tubes for precision applications - Technical delivery conditions - Part 6: Welded cold drawn tubes for hydraulic and pneumatic power systems
IEC 60227-3:1993+AMD1:1997 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring
IEC 61386-21:2002 Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems
EN 1453-1:2017/AC:2017 PLASTICS PIPING SYSTEMS WITH STRUCTURED-WALL PIPES FOR SOIL AND WASTE DISCHARGE (LOW AND HIGH TEMPERATURE) INSIDE BUILDINGS - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPES AND THE SYSTEM
ISO 13943:2017 Fire safety — Vocabulary
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
HD 22-4 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 4: CORDS AND FLEXIBLE CABLES
EN 12449:2016 Copper and copper alloys - Seamless, round tubes for general purposes
EN 61386-1:2008 Conduit systems for cable management - Part 1: General requirements
EN 10305-4:2016 Steel tubes for precision applications - Technical delivery conditions - Part 4: Seamless cold drawn tubes for hydraulic and pneumatic power systems
EN 1455-1:1999 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Acrylonitrile-butadiene-styrene (ABS) - Part 1: Requirements for pipes, fittings and the system
EN 13600:2013 Copper and copper alloys - Seamless copper tubes for electrical purposes
EN 1992-1-2:2004/AC:2008 EUROCODE 2: DESIGN OF CONCRETE STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
EN 12666-1:2005+A1:2011 Plastics piping systems for non-pressure underground drainage and sewerage - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 10025-2:2004/AC:2005 HOT ROLLED PRODUCTS OF STRUCTURAL STEELS - PART 2: TECHNICAL DELIVERY CONDITIONS FOR NON-ALLOY STRUCTURAL STEELS
EN 12201-2:2011+A1:2013 Plastics piping systems for water supply, and for drainage and sewerage under pressure - Polyethylene (PE) - Part 2: Pipes
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1519-1:1999 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system
EN 1996-1-2:2005/AC:2010 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
IEC 61386-1:2008+AMD1:2017 CSV Conduit systems for cable management - Part 1: General requirements
EN 1452-1 : 1999 PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: GENERAL
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
EN 1565-1:1998 Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Styrene copolymer blends (SAN+PVC) - Part 1: Specifications for pipes, fittings and the system
HD 604 S1:1994/A3:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more