Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50411-2-5:2009

Current
Current

The latest, up-to-date edition.

Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-5: Sealed closures for air blown fibre microduct, type 1, for category S & A
Published date

20-05-2009

1 Scope
   1.1 Product definition
   1.2 Operating environment
   1.3 Reliability
   1.4 Quality assurance
   1.5 Allowed fibre and cable types
   1.6 Allowed microduct connector types
   1.7 Microduct storage constraints
2 Normative references
3 Definitions and abbreviations
   3.1 Definitions
   3.2 Abbreviations
4 Description
   4.1 Microduct closure
   4.2 Closure housing functions
   4.3 Burst pressure
   4.4 Closure housing configurations
   4.5 Entry seals
   4.6 Common base configurations
   4.7 Microduct management system
   4.8 Materials
   4.9 Colour and marking
   4.10 Microduct connectors applications and capacity
5 Variants
6 Dimensional requirements
   6.1 Dimensions of inline closures
   6.2 Dimensions of tee closures
   6.3 Dimensions of pan closures
   6.4 Dimensions of dome closures
7 Tests
   7.1 Sample size
   7.2 Test sample preparation
   7.3 Test and measurement methods
   7.4 Test sequence
   7.5 Pass/fail criteria
8 Test report
9 Performance requirements
   9.1 Dimensional and marking requirements
   9.2 Sealing, optical and appearance performance criteria
   9.3 Mechanical sealing performance requirements
   9.4 Environmental sealing performance requirements
   9.5 Mechanical optical performance requirements
   9.6 Environmental optical performance requirements
Annex A (informative) - Fibre for test sample details
Annex B (informative) - Sample size and product sourcing
        requirements
Annex C (informative) - Closure minimum internal diameters,
        containing microduct connectors
Annex D (informative) - Typical buried blown fibre microduct
        cable outside diameters
Annex E (informative) - Microduct connector definitions and
        sketches
Annex F (informative) - Microduct minimum bend radius
Bibliography

1.1Product definition This specification contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a fully installed blown fibre protected microduct closure must meet in order for it to be categorised as an EN standard product. These products are suitable for installation of and use with microduct fibre units, microduct optical fibre cables, microduct and protected microduct as defined within EN 60794-5. 1.2Operating environment The tests selected combined with the severities and duration are representative of an outside plant for subterranean and/or aerial environment defined by: - ETSI EN 300 019 series:Class 8.1: underground locations (without earthquake requirement); - EN 61753-1:Category S: subterranean environment; Category A: aerial environment. 1.3Reliability Whilst the anticipated service life expectancy of the product in this environment is a minimum of 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.4Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme. 1.5Allowed fibre and cable types This closure standard covers all IEC standard optical fibre microducts, and protected microducts with their various fibre capacities, types and designs. This includes, but is not limited to, optical fibre cable standard EN 60794-5. This product specification has only considered protected microduct cables containing microducts of same outside diameters. There are other hybrid protected microduct cables with microducts of differing OD's, with too many variants to be included in this PS. 1.6Allowed microduct connector types This closure standard covers all EN standard microduct connectors, including: straight, reducer/enlarger stem, reducer/enlarger, close down, liquid block, liquid block with barb end, and end stop connectors. This includes, but is not limited to, EN 50411-2-8. 1.7Microduct storage constraints Microduct excess storage is not required in all air blown fibre closures. Some closure types do not have sufficient internal space to provide storage. The need for microduct storage is provided inside the closure when opened, typically to ensure that there is enough microduct to fulfil the following functions: - remove the coiled microduct attached to the 'closedown' connectors, to a remote location, close to blowing equipment, in the process uncoiling the microducts to aid blowing; - provide additional microduct if repeated cut backs for connectors are planned or likely to be fitted throughout the closure life. The minimum microduct storage bend radius is based on the outside diameter and material selection, typically based on 12 times the outside diameter (below 8 mm) and 20 times above. During fibre blowing the bend radius is typically 20 times the microduct diameter.

Committee
CLC/TC 86BXA
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

NF EN 50411-2-9 : 2010 FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATIONS SYSTEMS - PRODUCT SPECIFICATIONS - PART 2-9: NON-SEALED CLOSURES FOR AIR BLOWN FIBRE MICRODUCT CABLE, FOR CATEGORY S & A
CEI EN 50411-2-8 : 2010 FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 2-8: MICRODUCT CONNECTORS, FOR AIR BLOWN OPTICAL FIBRES, TYPE 1
BS EN 50174-3 : 2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
EN 50411-2-9:2010 Fibre organisers and closures to be used in optical fibre communications systems - Product specifications - Part 2-9: Non-sealed closures for air blown fibre microduct cable, for category S & A
I.S. EN 50411-2-9:2010 FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATIONS SYSTEMS - PRODUCT SPECIFICATIONS - PART 2-9: NON-SEALED CLOSURES FOR AIR BLOWN FIBRE MICRODUCT CABLE, FOR CATEGORY S & A
BS EN 50411-2-8:2009 Fibre organisers and closures to be used in optical fibre communication systems. Product specifications Microduct connectors, for air blown optical fibres, Type 1
CEI EN 50174-3 : 2014 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
12/30260552 DC : 0 BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
CEI EN 50411-2-9 : 2011 FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATIONS SYSTEMS - PRODUCT SPECIFICATIONS - PART 2-9: NON-SEALED CLOSURES FOR AIR BLOWN FIBRE MICRODUCT CABLE, FOR CATEGORY S & A
I.S. EN 50174-3:2013 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
PREN 50174-3 : DRAFT 2012 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
EN 50174-3:2013/A1:2017 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS
BS EN 50411-2-9:2010 Fibre organisers and closures to be used in optical fibre communications systems. Product specifications Non-sealed closures for air blown fibre microduct cable, for category S & A
I.S. EN 50411-2-8:2009 FIBRE ORGANISERS AND CLOSURES TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 2-8: MICRODUCT CONNECTORS, FOR AIR BLOWN OPTICAL FIBRES, TYPE 1
EN 50411-2-8:2009 Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-8: Microduct connectors, for air blown optical fibres, Type 1

EN 61300-2-5:2011 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion
IEC 61300-3-28:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss
EN 61300-2-1:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal)
EN 61300-2-10:2012 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-10: TESTS - CRUSH RESISTANCE (IEC 61300-2-10:2012)
EN 60793-2-50:2016 Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres
IEC 61300-2-37:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures
EN 61300-2-37:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures
EN 61300-2-23:2011 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-23: Tests - Sealing for non-pressurized closures of fibre optic devices
EN 50411-2-8:2009 Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-8: Microduct connectors, for air blown optical fibres, Type 1
IEC 61300-3-3:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss
IEC 61300-2-1:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal)
IEC 61300-2-12:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact
EN 61756-1 : 2006 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - INTERFACE STANDARD FOR FIBRE MANAGEMENT SYSTEMS - PART 1: GENERAL AND GUIDANCE
EN 61300-3-3:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss
IEC 61300-2-23:2010 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-23: Tests - Sealing for non-pressurized closures of fibre optic devices
IEC 60794-1-2:2017 Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance
EN 61300-2-38:2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-38: Tests - Sealing for pressurized fibre optic closures
IEC 61758-1:2008 Fibre optic interconnecting devices and passive components - Interface standard for closures - Part 1: General and guidance
EN 61300-2-22:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature
IEC 61753-1:2007 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards
EN 61753-1:2007 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards
IEC 61300-2-5:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion
IEC 61300-2-26:2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist
IEC 61300-2-38:2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-38: Tests - Sealing for pressurized fibre optic closures
EN 61300-2-33:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures
IEC 60794-5:2014 Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing
EN 61300-2-34:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures
ISO 1998-1:1998 Petroleum industry Terminology Part 1: Raw materials and products
IEC 61300-2-22:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature
EN 61300-3-1:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60068-2-10:2005 Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth
EN 61300-2-12:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact
IEC 61300-2-34:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures
EN 61300-2-4:1997 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention
EN 60794-5:2016 Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing
EN 61300-3-28:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-28: Examinations and measurements - Transient loss
IEC 60793-2-50:2015 Optical fibres - Part 2-50: Product specifications - Sectional specification for class B single-mode fibres
EN 60794-1-2:2017/AC:2017-07 OPTICAL FIBRE CABLES - PART 1-2: GENERIC SPECIFICATION - BASIC OPTICAL CABLE TEST PROCEDURES - GENERAL GUIDANCE (IEC 60794-1-2:2017)
IEC 61300-2-33:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures
IEC 61756-1:2006 Fibre optic interconnecting devices and passive components - Interface standard for fibre management systems - Part 1: General and guidance
IEC 61300-2-4:1995 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 61300-2-26:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist
IEC 61300-3-1:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination
IEC 61300-2-10:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-10: Tests - Crush resistance
EN 61758-1:2008 Fibre optic interconnecting devices and passive components - Interface standard for closures - Part 1: General and guidance

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more