EN 50443:2011

Current
Current

The latest, up-to-date edition.

Effects of electromagnetic interference on pipelines caused by high voltage a.c. electric traction systems and/or high voltage a.c. power supply systems
Published date

09-12-2011

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Procedure
5 Interference distance
6 Interference situations
7 Coupling types
8 Interference
9 Interference results
10 Limits for permissible interference
11 Evaluation of the interference results
12 Mitigation measures
Annex A (informative) - Indications to select
        interference situations
Annex B (informative) - Guidance for interference
        investigations
Annex C (informative) - Measuring methods
Annex D (informative) - Mitigation measures
Annex E (informative) - Management of interference
Annex F (informative) - A-deviations
Bibliography

The presence of ac power supply systems or of a.c. electric traction systems (in this standard also indicated as a.c. power systems) may cause voltages to build up in pipeline systems,(in this standard indicated as interfered systems) running in the close vicinity, due to one or more of the following mechanisms: inductive coupling, conductive coupling, capacitive coupling. Such voltages may cause danger to persons, damage to pipelines or connected equipment or disturbance to the electrical/ electronic equipment connected to the pipeline. This European Standard deals with the situations where these effects may arise and with the maximum tolerable limits of the interference effects, taking into account the behaviour of the ac power systems both in normal operating condition and/or during faults. NOTE In the worst case, the pipe may not disperse current to ground. As a consequence, the prospective touch voltage coincides with the interference voltage. This European Standard applies to all metallic pipelines irrespective of the conveyed fluid, e.g. liquid or gas, liable to be interfered by high voltage a.c. railway and high voltage a.c. power supply systems. The objective of this standard is to establish: the procedure for evaluating the e.m. interference; the interference distance to be considered; the types of coupling to be considered for operating and fault conditions of the high voltage a.c. electric traction systems and high voltage a.c. power supply systems; the configurations to be considered for both metallic pipeline and high voltage a.c. electric traction systems or high voltage a.c. power systems; the limits of the voltages due to the electromagnetic interference; information on interference situations, calculation methods, measuring methods, mitigation measures, management of interference. This European Standard is applicable to all new metallic pipelines and all new high voltage a.c. electric traction systems and high voltage a.c. power supply systems and all major modifications that may change significantly the interference effect. This European Standard only relates to phenomena at the fundamental power frequency (e.g. 50 Hz or 16,7 Hz). This European Standard does not apply to: all aspects of corrosion, the coupling from a.c. railway and power supply systems with nominal voltages less than or equal to 1 kV, interference effects on the equipment not electrically connected to the pipeline.

Committee
CLC/TC 9X
DevelopmentNote
Supersedes PREN 50443. (12/2011)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

Standards Relationship
NF EN 50443 : 2012 Identical
NBN EN 50443 : 2012 Identical
NEN EN 50443 : 2011 Identical
I.S. EN 50443:2011 Identical
PN EN 50443 : 2012 Identical
DIN EN 50443 : 2012 Identical
VDE 0845-8 : 2012 Identical
UNE-EN 50443:2011 Identical
BS EN 50443:2011 Identical
CEI EN 50443 : 2012 Identical

BS ISO 18086 : 2015 CORROSION OF METALS AND ALLOYS - DETERMINATION OF AC CORROSION - PROTECTION CRITERIA
DIN EN 15280 E : 2013 EVALUATION OF A.C. CORROSION LIKELIHOOD OF BURIED PIPELINES APPLICABLE TO CATHODICALLY PROTECTED PIPELINES
BS EN 15280:2013 Evaluation of a.c. corrosion likelihood of buried pipelines applicable to cathodically protected pipelines
ISO 15589-1:2015 Petroleum, petrochemical and natural gas industries — Cathodic protection of pipeline systems — Part 1: On-land pipelines
05/30136201 DC : DRAFT JUL 2005 CEN TS 15280 - EVALUATION OF A.C. CORROSION LIKELIHOOD OF BURIED PIPELINES - APPLICATION TO CATHODICALLY PROTECTED PIPELINES
BS ISO 15589-1 : 2015 PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - CATHODIC PROTECTION OF PIPELINE SYSTEMS - PART 1: ON-LAND PIPELINES
EN ISO 18086:2017 Corrosion of metals and alloys - Determination of AC corrosion - Protection criteria (ISO 18086:2015)
I.S. EN ISO 15589-1:2017 PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - CATHODIC PROTECTION OF PIPELINE SYSTEMS - PART 1: ON-LAND PIPELINES (ISO 15589-1:2015)
CEI EN 50341-2-23 : 1ED 2017 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 2-23: NATIONAL NORMATIVE ASPECTS (NNA) FOR SLOVAKIA (BASED ON EN 50341-1:2012)
PREN 12954 : DRAFT 2017 GENERAL PRINCIPLES OF CATHODIC PROTECTION OF BURIED OR IMMERSED ONSHORE METALLIC STRUCTURES
ISO 18086:2015 Corrosion of metals and alloys Determination of AC corrosion Protection criteria
EN ISO 15589-1:2017 Petroleum, petrochemical and natural gas industries - Cathodic protection of pipeline systems - Part 1: On-land pipelines (ISO 15589-1:2015, Corrected version 2020-11)
EN 50341-2-23:2016 Overhead electrical lines exceeding AC 1 kV – Part 2-23: National Normative Aspects (NNA) for SLOVAKIA (based on EN 50341-1:2012)
UNI EN 15280 : 2014 EVALUATION OF A.C. CORROSION LIKELIHOOD OF BURIED PIPELINES APPLICABLE TO CATHODICALLY PROTECTED PIPELINES
I.S. EN 15280:2013 EVALUATION OF A.C. CORROSION LIKELIHOOD OF BURIED PIPELINES APPLICABLE TO CATHODICALLY PROTECTED PIPELINES
I.S. EN 50341-2-23:2016 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 2-23: NATIONAL NORMATIVE ASPECTS (NNA) FOR SLOVAKIA (BASED ON EN 50341-1:2012)
17/30346281 DC : 0 BS EN 12954 - GENERAL PRINCIPLES OF CATHODIC PROTECTION OF BURIED OR IMMERSED ONSHORE METALLIC STRUCTURES
BS EN 50341-2-23:2016 Overhead electrical lines exceeding AC 1 kV National Normative Aspects (NNA) for SLOVAKIA (based on EN 50341-1:2012)
DIN EN 15280:2013-12 EVALUATION OF A.C. CORROSION LIKELIHOOD OF BURIED PIPELINES APPLICABLE TO CATHODICALLY PROTECTED PIPELINES
I.S. EN ISO 18086:2017 CORROSION OF METALS AND ALLOYS - DETERMINATION OF AC CORROSION - PROTECTION CRITERIA (ISO 18086:2015)
BS EN ISO 15589-1:2017 Petroleum, petrochemical and natural gas industries. Cathodic protection of pipeline systems On-land pipelines
EN 15280:2013 Evaluation of a.c. corrosion likelihood of buried pipelines applicable to cathodically protected pipelines

EN 50122-1:2011/A4:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
IEC 60050-195:1998 International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock
EN 14505:2005 Cathodic protection of complex structures
HD 384.6.61 : 200S2 ELECTRICAL INSTALLATIONS OF BUILDINGS - VERIFICATION - INITIAL VERIFICATION
EN 50110-1:2013 Operation of electrical installations - Part 1: General requirements
IEC 60364-6-61:2001 Electrical installations of buildings - Part 6-61: Verification - Initial verification
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more