Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50482:2008

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Instrument transformers - Three-phase inductive voltage transformers having Um up to 52 kV

Withdrawn date

11-03-2014

Published date

24-01-2008

1 General
   1.1 Scope
   1.2 Normative references
2 Definitions
3 General requirements
4 Normal and special service conditions
5 Ratings
   5.1 Standard values of rated voltages
   5.2 Standard values of rated output
   5.3 Standard values of rated voltage factor
   5.4 Limits of temperature rise
6 Design requirements
   6.1 Insulation requirements
   6.2 Short-circuit withstand capability
7 Classification of tests
8 Type tests
   8.1 Temperature-rise tests
   8.2 Short-circuit withstand capability test
   8.3 Impulse test on primary winding
   8.4 Wet test for outdoor type transformers
9 Routine tests
   9.1 Verification of terminal markings
   9.2 Power frequency tests on primary winding and partial
        discharge measurement
   9.3 Power-frequency tests between section and on secondary
        windings
10 Special test
11 Markings
   11.1 Rating plate and markings
   11.2 Terminal markings
12 Accuracy requirements for three-phase inductive measuring
   voltage transformers
   12.1 Accuracy class designation for measuring voltage
        transformers
   12.2 Limits of voltage error and phase displacement for
        measuring voltage transformers
   12.3 Type test for accuracy of measuring voltage transformers
   12.4 Routine test for accuracy of measuring voltage transformers
   12.5 Markings of the rating plate of three-phase measuring
        voltage transformer
13 Additional requirements for three-phase inductive protective
   voltage transformers
   13.1 Accuracy class designation for protective voltage
        transformers
   13.2 Limits of voltage error and phase displacement for
        protective voltage transformers
   13.3 Rated voltages for secondary windings intended to produce a
        residual voltage
   13.4 Output for secondary windings intended to produce a residual
        voltage
   13.5 Accuracy class for secondary windings intended to produce a
        residual voltage
   13.6 Type test for protective voltage transformers
   13.7 Routine test for protective transformers
   13.8 Markings of the rating plate of a three-phase protective
        voltage transformer
Bibliography

This European Standard specifies the requirements and tests for new three-phase voltage transformers with Um up to 52 kV and frequencies from 15 Hz to 100 Hz, for use with electrical instruments or electrical protective devices. NOTESingle-phase voltage transformers connected in a three-phase bank are not covered in this document.

Committee
CLC/TC 38
DevelopmentNote
Supersedes HD 587. To be read in conjunction with EN 60044-2. (01/2008)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn
Supersedes

Standards Relationship
BS EN 50482:2008 Identical
DIN EN 50482 : 2008 Identical
I.S. EN 50482:2008 Identical
PN EN 50482 : 2010 Identical
VDE 0414-6 : 2008 Identical
SN EN 50482 : 2008 Identical
NBN EN 50482 : 2008 Identical
NEN EN 50482 : 2008 Identical
CEI EN 50482 : 2015 Identical
NF EN 50482 : 2008 Identical
UNE-EN 50482:2009 Identical

EN 60044-2:1999/A2:2003 INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS
IEC 60038:2009 IEC standard voltages
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV Instrument transformers - Part 2 : Inductive voltage transformers
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more