Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 50541-1:2011

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
Superseded date

01-06-2015

Published date

29-04-2011

1 Scope
2 Normative references
3 Electrical characteristics
4 Tests
5 Design requirements
6 Terminals
7 Enclosure
8 Overall dimensional indications and accessories
9 Efficiency and drop voltage at reference temperature
Annex A (informative) - Capitalisation evaluation
Bibliography

This European Standard covers dry type transformers from 100 kVA to 3 150 kVA intended foroperation in three phases distribution networks, for indoor continuous service, 50 Hz, naturalcooling, with two windings:− a primary (high voltage) winding with a highest voltage for equipment of 3,6 kV to36 kV;− a secondary (low voltage) winding with a highest voltage for equipment not exceeding1,1 kV.For outdoor application, special design or enclosure (enclosure with adapted IP and IKdegrees protections) should be requested.NOTE 1 This European Standard may be applied, as a whole or in part to transformers having windings with morethan one rated voltage. In this case the rated power for each coupling ratio should be specified by the purchaser.NOTE 2 For dry type transformers installed in power generating plants, additional requirements, not covered bythis European Standard, and alternative requirements may be specified.NOTE 3 For dry type transformers dedicated to wind turbines applications additive requirements are specified inEN 60076-16.The object of this European Standard is to lay down requirements related to electricalcharacteristics, dimensions and designs of three phases distribution dry type transformers.These transformers should be in accordance with EN 60076-11 for general requirements.

Committee
CLC/TC 14
DevelopmentNote
Supersedes HD 538.2. (05/2011) Supersedes NBN HD 538.1. (07/2011) Supersedes PREN 50541-1. (08/2011) Supersedes HD 538.1, which remains current and will be withdrawn on 02-10-2014. (11/2011)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

17/30354643 DC : 0 BS EN 62933-2-1 - ELECTRIC ENERGY STORAGE (ESS) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
EN IEC 62933-2-1:2018 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
I.S. EN IEC 62933-2-1:2018 ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 2-1: UNIT PARAMETERS AND TESTING METHODS - GENERAL SPECIFICATION
IEC 62933-2-1:2017 Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
IEC 62271-202:2014 High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation
EN 60076-4:2002 Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors
IEC TR 60616:1978 Terminal and tapping markings for power transformers
EN 50387:2002 Busbar bushings up to 1 kV and from 1,25 kA to 5 kA, for liquid filled transformers
EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
EN 62271-202:2014/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014)
EN 50386:2010/A1:2013 BUSHINGS UP TO 1 KV AND FROM 250 A TO 5 KA, FOR LIQUID FILLED TRANSFORMERS
IEC 60076-4:1976 Power transformers - Part 4: Tappings and connections
IEC 60076-12:2008 Power transformers - Part 12: Loading guide for dry-type power transformers
EN 50180:2010 Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers – Part 1: General requirements for bushings
EN 60076-10:2016 Power transformers - Part 10: Determination of sound levels
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
EN 60076-16:2011 Power transformers - Part 16: Transformers for wind turbines applications
EN 50181:2010 Plug-in type bushings above 1 kV up to 52 kV and from 250 A to 2,50 kA for equipment other than liquid filled transformers
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC 60076-16:2011 Power transformers - Part 16: Transformers for wind turbine applications

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more