Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 60265-1:1998

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

High-voltage switches - Part 1: Switches for rated voltages above 1 kV and less than 52 kV

Superseded date

01-09-2011

Published date

02-04-1998

1 General
    1.1 Scope
    1.2 Normative references
          1.101 General requirements
2 Normal and special service conditions
3 Definitions
    3.1 General terms
    3.2 Assemblies
    3.3 Parts of assemblies
    3.4 Switching devices
    3.5 Parts of switching devices
    3.6 Operation
    3.7 Characteristic quantities
    3.8 Index of definitions
4 Ratings
    4.1 Rated voltage (Ur)
    4.2 Rated insulation level
    4.3 Rated frequency (fr)
    4.4 Rated normal current (lr) and temperature rise
    4.5 Rated short-time withstand current (lk)
    4.6 Rated peak withstand current (lp)
    4.7 Rated duration of short-circuit (tk)
    4.8 Rated supply voltage of closing and opening devices
          and of auxiliary and control circuits (Ua)
    4.9 Rated supply frequency of closing and opening
          devices and of auxiliary circuits
    4.10 Rated pressure of compressed gas supply for operation
          and/or interruption
          4.101 Rated mainly active load-breaking current (l1)
          4.102 Rated closed-loop breaking current (l2a and l2b)
          4.103 Rated no-load transformer breaking current (l3)
          4.104 Rated cable-charging breaking current (l4a)
          4.105 Rated line-charging breaking current (l4b)
          4.106 Rated single capacitor bank breaking current for
                 special purpose switches (l4c)
          4.107 Rated back-to-back capacitor bank breaking
                 current for special purpose switches (l4d)
          4.108 Rated back-to-back capacitor inrush making
                 current for special purpose switches (lin)
          4.109 Rated earth fault breaking current (l6a)
          4.110 Rated cable- and line-charging breaking
                 current under earth fault conditions (l6b)
          4.111 Rated motor breaking current for special
                 purpose switches (l7)
          4.112 Rated short-circuit making current (lma)
          4.113 Rated breaking and making currents for a
                 general purpose switch
          4.114 Ratings for limited purpose switches
          4.115 Ratings for special purpose switches
          4.116 Ratings for switches backed by fuses
5 Design and construction
    5.1 Requirements for liquids in high-voltage switches
    5.2 Requirements for gases in high-voltage switches
    5.3 Earthing of high-voltage switches
    5.4 Auxiliary and control equipment
    5.5 Dependent power operation
    5.6 Stored energy operation
    5.7 Independent manual operation
    5.8 Operation of releases
    5.9 Low- and high-pressure interlocking and monitoring
          devices
    5.10 Nameplates
    5.11 Interlocking devices
    5.12 Position indication
    5.13 Degrees of protection by enclosures
    5.14 Creepage distances
    5.15 Gas and vacuum tightness
    5.16 Liquid tightness
    5.17 Flammability
    5.18 Electromagnetic compatibility (EMC)
          5.101 Making and breaking operations
          5.102 Requirements for switch-disconnectors
          5.103 Mechanical strength
          5.104 Securing the position
          5.105 Auxiliary contacts for signalling
6 Type tests
    6.1 General
    6.2 Dielectric tests
    6.3 Radio interference voltage (RIV) tests
    6.4 Measurement of the resistance of the main circuit
    6.5 Temperature-rise tests
    6.6 Short-time withstand current and peak withstand current
          tests
    6.7 Verification of the protection
    6.8 Tightness tests
    6.9 Electromagnetic compatibility (EMC) tests
          6.101 Making and breaking tests
          6.102 Mechanical operation tests
          6.103 Operation under severe ice conditions
7 Routine tests
          7.101 Mechanical operating tests
8 Guide to the selection of high-voltage switches for service
    8.1 General
    8.2 Conditions affecting application
    8.3 Insulation coordination
    8.4 Selection of class of switch
9 Information to be given with inquiries, tenders and orders
    9.1 Information to be given with inquiries and orders
          9.102 Information to be given with tenders
10 Rules for transport, storage, erection, operation and
    maintenance
11 Safety
Tables
1 Rated line- and cable-charging breaking currents for
    general purpose switch
2 Nameplate information
3 Supply circuit TRV parameters for mainly active load
    current breaking tests
4a TRV parameters for distribution line closed loop breaking
    tests
4b TRV parameters for parallel power transformer current
    breaking tests
5 Test duties for general purpose switches - Test duties
    for three-phase tests on three-pole operated,
    pole-after-pole operated, and single pole switches
6 Test duties for general purpose switches - Single phase
    tests on three-pole switches operated pole-after-pole and
    single-pole switches applied on three-phase systems
7 Test duties for special purpose switches - Three-phase
    tests on three-pole operated, pole-after-pole operated,
    and single-pole switches
8 Test duties for special purpose switches - Single phase
    tests on three-pole switches operated pole-after-pole and
    single-pole switches applied on three-phase systems
9 Prospective recovery voltage parameter limits for
    single-phase capacitor bank current breaking tests
Figures
1 Three-phase test circuit for mainly active load current
    switching for test duty 1
2 Single-phase test circuit for mainly active load current
    switching for test duty 1
3 Three-phase test circuit for distribution line closed-loop
    and parallel transformer current switching test for test
    duties 2a and 2b
4 Single-phase test circuit for distribution line closed-loop
    and parallel transformer current switching test, for test
    duties 2a and 2b
5 Three-phase test circuit for short-circuit making current
    test for test duty 5
6 Single-phase test circuit for short-circuit making current
    test for test duty 5
7 Prospective TRV parameter limits for single-phase capacitor
    bank current breaking tests
8 Three-phase test circuit for earth fault breaking current
    tests, for test duty 6a
9 Three-phase test circuit for cable-charging breaking
    current tests under earth fault conditions, for test duty
    6b
Annex ZA Normative references to international publications
with their corresponding European publications

Is applicable to three-phase, alternating current switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from 16 2/3 Hz up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.

Committee
CLC/TC 17AC
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

UNE-EN 60282-1:2011 High-voltage fuses - Part 1: Current-limiting fuses
DIN EN 45510-2-7:2003-12 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
CEI EN 60282-1 : 2011 HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES
BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
NF EN 50119 : 2010 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 45510-2-7:2002 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
I.S. EN 62271-102:2005 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV))

IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60056:1987 High-voltage alternating-current circuit-breakers
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 60129:1984 Alternating current disconnectors and earthing switches
IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 60420:1990 High-voltage alternating current switch-fuse combinations

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more