Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 60433:1998

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Insulators for overhead lines with a nominal voltage above 1 kV - Ceramic insulators for a.c. systems - Characteristics of insulator units of the long rod type
Superseded date

09-03-2021

Published date

22-10-1998

FOREWORD
1 Scope
2 Normative references
3 Definition
4 Characteristics
5 Designation and marking
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Prescribes specified values for the electrical and mechanical characteristics and for the principal dimensions of string insulator units of the long rod type with insulating parts of ceramic material intended for a.c. overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It is also applicable to insulators of similar design, used in substations. Applies also to string insulator units: -of the long rod type either with a clevis at both ends for coupling with a tongue, or with a socket at both ends for coupling with a pin ball -with external metal fittings -for use on overhead lines situated in slightly polluted areas, and the creepage distances given in Tables I and II have been established accordingly -and insulators of similar design, used in substations. This standard may be regarded as a provisional standard for insulators for d.c. overhead lines. Note -For general definitions and methods of tests see EN 60383. -For dimensions of clevis and tongue couplings of string insulator units, see IEC 60471. -For dimensions of ball and socket couplings of string insulator units, see EN 60120.

Committee
CLC/SR 36
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Standards Relationship
IEC 60433:1998 Identical
NF EN 60433 : 2000 Identical
I.S. EN 60433:1998 Identical
CEI EN 60433 : 1999 Identical
NEN EN IEC 60433 : 1999 Identical
BS EN 60433:1999 Identical
UNE-EN 60433:1999 Identical
SN EN 60433 : 1998 Identical
DIN EN 60433 : 1999 Identical
PN EN 60433 : 2001 Identical
NBN EN 60433 : 1999 Identical
VDE 0446-7 : 1999 Identical

UNE-EN 50341-1:2017 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
NF EN 50119 : 2010 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS

EN 60672-1:1995 Ceramic and glass insulating materials - Part 1: Definitions and classification
IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
IEC 60672-3:1997 Ceramic and glass-insulating materials - Part 3: Specifications for individual materials
EN 60383-1:1996/A11:1999 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
EN 60672-3:1997 Ceramic and glass-insulating materials - Part 3: Specifications for individual materials
HD 474 : 200S1 DIMENSIONS OF BALL AND SOCKET COUPLINGS OF STRING INSULATOR UNITS
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 60120:1984 Dimensions of ball and socket couplings of string insulator units
IEC 60672-1:1995 Ceramic and glass insulating materials - Part 1: Definitions and classification

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more