Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 60044-8:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Instrument transformers - Part 8: Electronic current transformers

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

27-04-2016

Language(s)

English, Spanish, Castilian

Published date

19-07-2002

FOREWORD
1 Scope
   1.1 General
   1.2 General block diagram of electronic current transformers
   1.3 General block diagram of electronic transformers with a
        digital output
2 Normative references
3 Definitions
   3.1 General definitions
   3.2 Additional definitions for measuring electronic current
        transformers
   3.3 Additional definitions for protective electronic current
        transformers
   3.4 Additional definitions for digital output
   3.5 Additional definitions for analogue voltage output
   3.6 Index of main definitions and abbreviations
4 Normal and special service conditions
   4.1 General
   4.2 Normal service conditions
   4.3 Special service conditions
   4.4 System earthing
5 Ratings
   5.1 General ratings
   5.2 Standard values for rated phase offset
   5.3 Rating for digital output
   5.4 Rating for analogue voltage output
6 Design requirements
   6.1 General design requirements
   6.2 Design requirements for digital output
   6.3 Design requirements for analogue voltage output
7 Classification of tests
   7.1 General
   7.2 Type tests
   7.3 Routine tests
   7.4 Special tests
8 Type test
   8.1 Short-time current tests
   8.2 Temperature-rise test
   8.3 Impulse tests on primary terminals
   8.4 Wet test for outdoor type electronic current transformers
   8.5 RIV tests
   8.6 Transmitted overvoltage test
   8.7 Low-voltage components voltage withstand test
   8.8 EMC tests
   8.9 Accuracy test
   8.10 Additional accuracy tests for protective electronic current
        transformers
   8.11 Verification of the protection
   8.12 Tightness tests
   8.13 Vibration tests
   8.14 Additional type test for digital output
9 Routine tests
   9.1 Verification of terminal markings
   9.2 Power-frequency withstand tests on primary terminals
        and partial discharge measurement
   9.3 Power-frequency voltage withstand test for low-voltage
        components
   9.4 Accuracy tests
   9.5 Tightness tests
   9.6 Additional routine tests for digital output
   9.7 Additional routine tests for analogue output
10 Special tests
   10.1 Chopped lightning-impulse test on primary terminals
   10.2 Measurement of capacitance and dielectric dissipation
        factor
   10.3 Mechanical tests
   10.4 Tests for accuracy versus harmonics
   10.5 Tests in accordance with the technology applied
11 Marking
   11.1 Terminal marking - General rules
   11.2 Rating plate markings
12 Additional requirements for measuring electronic current
   transformers
   12.1 Accuracy class designation
   12.2 Limits of current error and phase error at rated frequency
   12.3 Accuracy requirements on harmonics
13 Additional requirements for protective electronic current
   transformers
   13.1 Accuracy classes
   13.2 Accuracy requirements on harmonics
14 Information to be given with enquiries, tenders and orders
   14.1 Designation
   14.2 Dependability
15 Rules for transport, storage and installation
   15.1 Conditions during transport, storage and installation
   15.2 Installation
   15.3 Unpacking and lifting
   15.4 Assembly
   15.5 Operation
   15.6 Maintenance
16 Safety
   16.1 Electrical aspects
   16.2 Mechanical aspects
   16.3 Thermal aspects
Annex A (informative) Transient performances of ECTs
Annex B (informative) Technical information for electronic
        current transformers with digital output
Annex C (informative) Technical information for electronic
        current transformers with analogue output
Annex D (normative) Frequency response and accuracy requirements
        on harmonics for electronic current and voltage transformer
Annex E (informative) Graph explaining the accuracy requirements
Bibliography
Figures
Tables

This part of IEC 60044 applies to newly manufactured electronic current transformers having an analogue voltage output or a digital output, for use with electrical measuring instruments and electrical protective devices at nominal frequencies from 15 Hz to 100 Hz.

Committee
TC 38
DevelopmentNote
Stability Date: 2016. (10/2012)
DocumentType
Standard
Pages
124
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

UNE-EN 62271-205:2011 High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV
BS EN 60255-1:2010 Measuring relays and protection equipment Common requirements
I.S. EN 50463-2:2017 RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING
17/30326671 DC : 0 BS ISO 27919-1 - CARBON DIOXIDE CAPTURE - PART 1: PERFORMANCE EVALUATION METHODS FOR POST-COMBUSTION CO[2] CAPTURE INTEGRATED WITH A POWER PLANT
PREN 50463-2 : DRAFT 2015 RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING
BS EN 50463-2:2017 Railway applications. Energy measurement on board trains Energy measuring
15/30329546 DC : 0 BS EN 50463-2 - RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING
03/113813 DC : 0 IEC 60034-2. ED.4 - ROTATING ELECTRICAL MACHINES - PART 2: METHODS FOR DETERMINING LOSSES AND EFFICIENCY FROM TESTS (EXCLUDING MACHINES FOR TRACTION VEHICLES)
IEEE C37.241-2017 IEEE Guide for Application of Optical Instrument Transformers for Protective Relaying
I.S. EN 61869-6:2016 INSTRUMENT TRANSFORMERS - PART 6: ADDITIONAL GENERAL REQUIREMENTS FOR LOW-POWER INSTRUMENT TRANSFORMERS
NF EN 62271-205 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
EN 62271-205:2008/corrigendum:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
EN 61869-6:2016 Instrument transformers - Part 6: Additional general requirements for low-power instrument transformers
EN 61850-9-1:2003 Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
EN 60688:2013 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
MIL-DTL-32483 Base Document:2013 Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard
MIL-DTL-917 Revision F:2014 ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR
14/30284930 DC : 0 BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS
11/30241212 DC : DRAFT JAN 2011 BS EN 60688 - ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS
UNE-EN 61557-12:2010 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 12: Performance measuring and monitoring devices (PMD)
IEC TS 61850-2:2003 Communication networks and systems in substations - Part 2: Glossary
IEEE C57.13.1-2006 REDLINE IEEE Guide for Field Testing of Relaying Current Transformers
IEC 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements
BS EN 61869-6:2016 Instrument transformers Additional general requirements for low-power instrument transformers
I.S. EN 60143-2:2013 SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS (IEC 60143-2:2012 (EQV))
PD IEC/TR 61850-90-4:2013 Communication networks and systems for power utility automation Network engineering guidelines
DD IEC/TS 61850-2:2003 Communication networks and systems in substations Glossary
BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
BS EN 62689-2:2017 Current and voltage sensors or detectors, to be used for fault passage indication purposes System aspects
CEI EN 61850-9-1 : 2015 COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SYSTEM MAPPINGS (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK
BS EN 60143-2:2013 Series capacitors for power systems Protective equipment for series capacitor banks
EN 50463-2:2017 Railway applications - Energy measurement on board trains - Part 2: Energy measuring
CEI EN 60143-2 : 2014 SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS
I.S. EN 61557-12:2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD)
I.S. EN 62271-205:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
IEC 61869-9:2016 Instrument transformers - Part 9: Digital interface for instrument transformers
BS EN 61850-9-1:2003 Communication networks and systems in substations. Specific communication service mapping (SCSM) Sampled values over serial unidirectional multidrop point to point link
EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements
BS EN 60688:2013 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
BS EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements
IEC 61557-12:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)
I.S. EN 61850-9-1:2003 COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SERVICE MAPPING (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK
I.S. EN 62689-2:2017 CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: SYSTEM ASPECTS
IEEE C37.233 : 2009 GUIDE FOR POWER SYSTEM PROTECTION TESTING
IEEE DRAFT C57.13-1 : D8.0 2006 FIELD TESTING OF RELAYING CURRENT TRANSFORMERS
I.S. EN 62689-1:2016 CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
CEI EN 60255-1 : 2011 MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS
CEI EN 61557-12 : 2013 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD)
IEC 62689-2:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects
CEI EN 62271-205 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
IEC 60255-1:1967 Electrical relays - Part 1: Instantaneous all-or-nothing relays
IEC 60688:2012 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
UNE-EN 60255-1:2010 Measuring relays and protection equipment -- Part 1: Common requirements
IEC 61850-9-1:2003 Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
IEC 60143-2:2012 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks
IEC TR 61869-103:2012 Instrument transformers - The use of instrument transformers for power quality measurement
IEC 62271-205:2008 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
UNE-EN 60688:2013 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
15/30328086 DC BS EN 61557-12. Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Part 12. Power metering and monitoring devices (PMD)
BS EN 61557-12:2008 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Performance measuring and monitoring devices (PMD)
11/30245197 DC : 0 BS EN 60143-2 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENTS FOR SERIES CAPACITOR BANKS
EN 62689-2:2017 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects
12/30268049 DC : 0 BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
BS EN 62271-205:2008 High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV
14/30300261 DC : 0 BS EN 62689-1 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: SYSTEM ASPECTS
I.S. EN 60688:2013 ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. AND D.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS (IEC 60688:2012 (EQV))
NF EN 60255-1 : 2010 MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS
I.S. EN 60255-1:2010 MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS
IEC 62888-2:2018 Railway applications - Energy measurement on board trains - Part 2: Energy measurement
IEC 61972:2002 Method for determining losses and efficiency of three-phase cage induction motors
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
EN 61557-12:2008 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)
EN 60255-1:2010 Measuring relays and protection equipment - Part 1: Common requirements
EN 60143-2:2013 Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks

IEC 61025:2006 Fault tree analysis (FTA)
IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
IEC 60874-10:1992 Connectors for optical fibres and cables - Part 10: Sectional specification - Fibre optic connector type BFOC/2,5
IEC 61000-4-10 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-10: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY MAGNETIC FIELD IMMUNITY TEST
IEC 60255-22-1:2007 Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests
EN 50160 : 2010 AMD 1 2015 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
IEC 60038:2009 IEC standard voltages
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60044-7:1999 Instrument transformers - Part 7: Electronic voltage transformers
IEC 60028:1925 International standard of resistance for copper
IEC 61850-9-1:2003 Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 60812:2006 Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA)
IEC TS 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60255-24:2013 Measuring relays and protection equipment - Part 24: Common format for transient data exchange (COMTRADE) for power systems
IEC 60599:2015 Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-12 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-12: TESTING AND MEASUREMENT TECHNIQUES - RING WAVE IMMUNITY TEST
IEC 61508-3:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508)
IEC 60056:1987 High-voltage alternating-current circuit-breakers
IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEC 60567:2011 Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance
IEC 61166:1993 High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60721-2-2:2012 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
IEC 61000-4-9 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-9: TESTING AND MEASUREMENT TECHNIQUES - IMPULSE MAGNETIC FIELD IMMUNITY TEST
IEC 60707:1999 Flammability of solid non-metallic materials when exposed to flame sources - List of test methods
IEC 60044-6:1992 Instrument transformers - Part 6: Requirements for protective current transformers for transient performance
IEC 60437:1997 Radio interference test on high-voltage insulators
IEC 60121:1960 Recommendation for commercial annealed aluminium electrical conductor wire
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV Instrument transformers - Part 1: Current transformers
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60376B:1974 Second supplement: Clause 26
IEC 60255-5:2000 Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests
IEC 61850-7-4:2010 Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
IEC 60050-321:1986 International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60721-2-4:1987+AMD1:1988 CSV Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature
TIA 485 : A1998(R2012) ELECTRICAL CHARACTERISTICS OF GENERATORS AND RECEIVERS FOR USE IN BALANCED DIGITAL MULTIPOINT SYSTEMS
IEC 60870-5-1:1990 Telecontrol equipment and systems. Part 5: Transmission protocols - Section One: Transmission frame formats
IEC 61508-1:2010 Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 61754-15:2009 Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 15: Type LSH connector family
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61754-1:2013 Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 1: General and guidance
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
IEC 61850-3:2013 Communication networks and systems for power utility automation - Part 3: General requirements

View more information
$979.95
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more