INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Types of tap-changer
   5.1 General
   5.2 On-load tap-changers
   5.3 Off-circuit tap-changers
   5.4 Liquid-immersed tap-changers
   5.5 Dry-type tap-changers
   5.6 Other types
   5.7 Protective devices
6 Selection of tap-changers
   6.1 General
   6.2 On-load tap-changers
   6.3 Off-circuit tap-changers
7 Location of liquid-immersed tap-changers
   7.1 Tap selectors
   7.2 Diverter and selector switches
8 Fittings
   8.1 Valves, air-release vents and liquid sampling devices
   8.2 Liquid level gauges
   8.3 Low liquid level alarms
   8.4 Nameplate and other plates
   8.5 Devices to aid maintenance
   8.6 Dehydrating breathers
9 Field service (operation, maintenance and monitoring)
   9.1 Operation
   9.2 Maintenance
   9.3 Monitoring in service
10 Information to be provided by the transformer manufacturer
   10.1 Information required at the enquiry or order stage for
        an on-load tap-changer
   10.2 Information required with enquiry or order for
        off-circuit tap-changers
   10.3 Documentation
11 Protection and safety
   11.1 Protection
   11.2 Safety aspects
   11.3 Immersing medium

Assists in the selection of tap-changers designed in accordance with IEC 60214-1 for use in conjunction with the tapped windings of transformers or reactors. Also assists in understanding the various types of tap-changers and their associated equipment available. Covers both on-load tap-changers and off-circuit tap-changers.

Committee
TC 14
DevelopmentNote
Supersedes IEC 60542. (10/2004) Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
37
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
UNE-IEC 60214-2:2006 Identical
NF EN 60214-2 : 2003 PR Identical
AS 60214.2-2006 Identical
CEI 14-41 : 2011 Identical

BS EN 60214-1:2014 Tap-changers Performance requirements and test methods
16/30336914 DC : 0 BS EN 60076-57-129 ED 1.0 - CONVERTOR TRANSFORMERS - PART 57-129: TRANSFORMERS FOR HVDC APPLICATIONS
17/30331680 DC : 0 BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS
13/30265253 DC : 0 BS EN 60214-1 ED 2 - TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
CEI 14-42 : 2011 CONVERTER TRANSFORMERS - PART 3: APPLICATION GUIDE
IEEE C57.15-2009 REDLINE IEEE Standard Requirements, Terminology, and Test Code for Step-Voltage Regulators
10/30232718 DC : 0 BS EN 60076-3 - POWER TRANSFORMERS - PART 3: INSULATION LEVELS, DIELECTRIC TESTS AND EXTERNAL CLEARANCES IN AIR
BS IEC 61378-3:2015 Converter transformers Application guide
IEC/IEEE 60076-57-129:2017 Power transformers - Part 57-129: Transformers for HVDC applications
IEC 61378-3:2015 Converter transformers - Part 3: Application guide
NF EN 60214-1 : 2015 TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
IEC 60076-21:2011 Power transformers - Part 21: Standard requirements, terminology, and test code for step-voltage regulators
IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods
C88-16 Power transformers and reactors
BS IEC 60076-21:2011 Power transformers Standard requirements, terminology, and test code for step-voltage regulators
UNE-EN 60214-1:2015 Tap-changers - Part 1: Performance requirements and test methods
I.S. EN 60214-1:2014 TAP-CHANGERS - PART 1: PERFORMANCE REQUIREMENTS AND TEST METHODS
EN 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods

IEC 60599:2015 Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
IEC 60354:1991 Loading guide for oil-immersed power transformers
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods

View more information
$405.17
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more