Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 60469-1:1987

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Pulse techniques and apparatus. Part 1: Pulse terms and definitions

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

23-04-2013

Language(s)

English - French

Published date

30-12-1987

Contents
Foreword
Preface
Clause
1. General
    1.1 Scope
    1.2 Object
2. General terms
    2.1 Co-ordinate system
    2.2 Wave, pulse and transition
    2.3 Waveform, epoch and feature
    2.4 Qualitative adjectives
    2.5 Quantitative adjectives
    2.6 Time-related definitions
    2.7 Reference lines and points
    2.8 Miscellaneous
3. The single pulse waveform
    3.1 Major pulse waveform features
    3.2 Magnitude characteristics and references
    3.3 Time characteristics and references
    3.4 Other pulse waveform features
4. The single transition waveform
    4.1 Step
    4.2 Ramp
5. Complex waveforms
    5.1 Combinations of pulses and transitions
    5.2 Waveforms produced by magnitude superposition
    5.3 Waveforms produced by continuous time
         superposition of simpler waveforms
    5.4 Waveforms produced by non-continuous time
         superposition of simpler waveforms
    5.5 Waveforms produced by operations on waveforms
6. Time relationships between different pulse waveforms
7. Distortion, jitter and fluctuation
    7.1 Distortion
    7.2 Qualitative distortion terms
    7.3 Jitter and fluctuation
8. Miscellaneous pulse terms
    8.1 Operations on a pulse
    8.2 Operations by a pulse
    8.3 Operations involving the interaction of pulses
    8.4 Logical operations with pulses
Figures
Index

Provides fundamental definitions for general use in time domain pulse technology. It defines terms for pulse phenomena and characteristics which are prerequisite for efficient communication of technical information. It also defines terms for standards for methods of pulse characteristics measurement, for pulse apparatus, and for apparatus which employ pulse techniques.

DevelopmentNote
Also numbered as BS 5698-1(1989) (08/2005) Stability Date: 2012. (10/2012)
DocumentType
Standard
Pages
51
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NEN 10469-1 : 1977 Identical
NFC 42 690 : 1988 Identical
DIN IEC 60469-1:1991-05 Identical
NEN IEC 60469-1 : 1999 Identical
BS 5698-1:1979 Identical

I.S. EN 61102:1994 MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ
04/30115966 DC : DRAFT JUL 2004
08/30173423 DC : DRAFT JULY 2008 BS EN 60601-2-5 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
15/30325282 DC : 0 BS EN 62884-1 - MEASUREMENT TECHNIQUES OF PIEZOELECTRIC, DIELETIRIC AND ELECTROSTATIC OSCILLATORS - PART 1: BASIC METHODS FOR THE MEASUREMENT
02/207233 DC : DRAFT JULY 2002 IEC 61000-4-5 ED.2 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST
05/30132097 DC : DRAFT JUNE 2005 IEC 60679-1 ED 3 - QUARTZ CRYSTAL CONTROLLED OSCILLATORS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION
IEC 60747-1:2006+AMD1:2010 CSV Semiconductor devices - Part 1: General
DIN IEC 60384-1:1991-11 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
CSA C22.2 No. 60601.2.5 : 2011 : R2016 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
BS IEC 60747-1 : 2006 SEMICONDUCTOR DEVICES - PART 1: GENERAL
BS EN 62127-1 : 2007 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ
EN 61689:2013 Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
CSA C22.2 No. 60601.2.5:2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
UNE-EN 60601-2-5:2016 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
CSA CEI/IEC 61000.4.9 : 2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-9: TESTING AND MEASUREMENT TECHNIQUES - PULSE MAGNETIC FIELD IMMUNITY TEST
BS EN 61102:1994 Specification for measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz
DIN 5483-1:1983-06 TIME-DEPENDENT QUANTITIES - TERMS FOR THE TIME-DEPENDENCY
BS EN 61828:2002 Ultrasonics. Focusing transducers. Definitions and measurement methods for the transmitted fields
CSA E60384.1 : 2014 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
14/30282293 DC : 0 BS EN 60679-1 - PIEZOELECTRIC AND ASSOCIATED MATERIAL OSCILLATORS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION
BS EN 60601-2-5:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
CEI EN 61689 : 2013 ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ
BS EN 61689:2013 Ultrasonics. Physiotherapy systems. Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
CEI EN 61828 : 2003 ULTRASONICS - FOCUSING TRANSDUCERS - DEFINITIONS AND MEASUREMENT METHODS FOR THE TRANSMITTED FIELDS
BIS IS 14700-4-5 : 2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4: TESTING AND MEASUREMENT TECHNIQUES - SECTION 5: SURGE IMMUNITY TEST
EN 61828:2001 Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields
I.S. EN 61689:2013 ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ (IEC 61689:2013 (EQV))
I.S. EN 60384-1:2016 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
CSA C22.2 No. 601.2.5 : 0 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
I.S. EN 60601-2-5:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
10/30197386 DC : 0 BS ISO 12013-2 - PAINTS AND VARNISHES - DETERMINATION OF CURING CHARACTERISTICS USING A FREE-DAMPED OSCILLATION METHOD - PART 2: GLASS-TRANSITION TEMPERATURE
11/30228838 DC : 0 BS EN 61157 A1 - STANDARD MEANS FOR THE REPORTING OF THE ACOUSTIC OUTPUT OF MEDICAL DIAGNOSTIC ULTRASONIC EQUIPMENT
STANAG 4193 (PT4) : 0 TECHNICAL CHARACTERISTICS OF IFF MK XA AND MK XII INTERROGATORS AND TRANSPONDERS - PART IV: TECHNICAL CHARACTERISTICS OF MODE S IN MILITARY INTERROGATORS AND TRANSPONDERS
NF EN 60601-2-5 : 2005 MEDICAL ELECTRICAL EQUIPMENT - PART 2-5: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ULTRASONIC PHYSIOTHERAPY EQUIPMENT
14/30280850 DC : 0 BS EN 60384-1 - FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
15/30326099 DC : 0 BS EN 61828 - ULTRASONICS - FOCUSING TRANSDUCERS - DEFINITIONS AND MEASUREMENT METHODS FOR THE TRANSMITTED FIELDS
06/30149145 DC : DRAFT OCT 2006 IEC 60384-1 - FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT - PART 1: GENERIC SPECIFICATION
BS EN 130000:1994 Harmonized system of quality assessment for electronic components. Generic specification: fixed capacitors
CSA IEC 61000-4-5: 2008 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST
IEC 61828:2001 Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields
IEC 62127-1:2007+AMD1:2013 CSV Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz
11/30243576 DC : DRAFT FEB 2011 BS EN 62643-1 - ELECTROSTATIC MICRO ELECTRO MECHANICAL SYSTEMS (MEMS) OSCILLATORS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION
10/30197383 DC : 0 BS ISO 12013-1 - PAINTS AND VARNISHES - DETERMINATION OF CURING CHARACTERISTICS USING A FREE-DAMPED OSCILLATION METHOD - PART 1: START TEMPERATURE OF REACTION
11/30230872 DC : 0 BS EN 61689 - ULTRASONICS - PHYSIOTHERAPY SYSTEMS - FIELD SPECIFICATIONS AND METHODS OF MEASUREMENT IN THE FREQUENCY RANGE 0,5 MHZ TO 5 MHZ
04/30122195 DC : DRAFT SEP 2004 IEC 60747-1 - SEMICONDUCTOR DEVICES - DISCRETE DEVICES AND INTEGRATED CIRCUITS - PART 1: GENERAL
CAN/CSA-IEC 61000-4-5-08 (R2017) Electromagnetic Compatibility (EMC) - Part 4-5: Testing and Measurement Techniques - Surge Immunity Test (Adopted IEC 61000-4-5:2005, second edition, 2005-11) | Compatibilité électromagnétique (CEM) - Partie 4-5: Techniques d\'essai et de mesure - Essai d\'immunité aux ondes de choc (norme IEC 61000-4-5:2005 adoptée, deuxième édition, 2005-11)
CSA IEC 61000-4-5 : 2008 : R2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST
I.S. EN 62127-1:2007 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007 (EQV))
IEC 60601-2-5:2009 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
EN 62127-1:2007/A1:2013 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007/A1:2013)
IEC 61689:2013 Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz
EN 61102:1993/A1:1994 MEASUREMENT AND CHARACTERISATION OF ULTRASONIC FIELDS USING HYDROPHONES IN THE FREQUENCY RANGE 0.5 MHZ TO 15 MHZ
EN 60601-2-5:2015 Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment

View more information
$465.48
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more