Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 61037:1990+AMD1:1996+AMD2:1998 CSV

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electricity metering - Tariff and load control - Particular requirements for electronic ripple control receivers
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

17-05-2004

Language(s)

English - French

Published date

12-08-1998

FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 Definitions
4 Requirements
5 Tests and test conditions
Annexes (normative)
A Relationship between ambient air temperature and
   relative humidity
B Reference and limiting values of the influence
   quantities
C Electromagnet for testing the influence of
   externally-produced magnetic fields
D Harmonic levels
E Selection of frequency for tests with harmonics
F Combination of parameters for operation and
   non-operation tests
Annexes (informative)
G Acceptance tests
H Code terms
J Example of a test configuration
K Values of the influence quantities for the different
   tests
Tables

Specifies requirements for the type test of indoor self-contained static ripple control receivers for the reception and interpretation of pulses of a single audio frequency superimposed on the voltage of the electricity distribution network and for the execution of the corresponding switching operations.Requirements for constructional details internal to the receivers are not specified.

DocumentType
Standard
Pages
83
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

BS EN 61000-2-12:2003 Electromagnetic compatibility (EMC). Environment Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
I.S. EN 61000-2-12:2003 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
EN 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
EN 61000-2-2:2002/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017)
CSA C61000.2.2 : 2004 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
CSA C61000.2.12 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
BS EN 61000-2-2 : 2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
CEI EN 61000-2-12 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
CAN/CSA-C61000-2-2-04 (R2018) Electromagnetic Compatibility (EMC) - Part 2-2: Environment - Compatibility Levels for Low-Frequency Conducted Disturbances and Signalling in Public Low-Voltage Power Supply Systems (Adopted CEI/IEC 61000-2-2:2002, second edition, 2002-03, with Canadian deviations) | Compatibilité électromagnétique (CEM) - Partie 2-2: Environnement - Niveaux de compatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux sur les réseaux publics d\'alimentation basse tension (norme CEI/IEC 61000-2-2:2002 adoptée, deuxième édition, 2002-03, avec exigences propres au Canada)
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
CSA C61000.2.12 : 2004 : R2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-12: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC MEDIUM-VOLTAGE POWER SUPPLY SYSTEMS
CSA C61000.2.2 : 2004 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS

IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 60817:1984 Spring-operated impact-test apparatus and its calibration
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
IEC 60417-2:1998 Graphical symbols for use on equipment - Part 2: Symbol originals
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
$943.21
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more