FOREWORD
1 Scope and object
2 Normative references
3 Terms and definitions
4 Classification of assemblies
   4.1 According to type of radiation to be measured
   4.2 According to type of surface
   4.3 According to type
5 Design characteristics
   5.1 Positioning of user
   5.2 Size of user
   5.3 Hand monitoring facilities
   5.4 Foot monitoring facilities
   5.5 Body monitoring facilities
   5.6 Visual display
   5.7 Audible indicators
   5.8 Monitoring period
   5.9 Ease of decontamination
   5.10 Detectors used
6 Performance requirements and test procedures
   6.1 General test procedure
   6.2 Statistical fluctuations
   6.3 Reference sources
   6.4 Nature of tests
   6.5 Use of gas flow detectors
7 Radiation characteristics
   7.1 Variation of response with source position
   7.2 Background
   7.3 Decision threshold (minimum detectable surface emission
        rate)
   7.4 Variation of response with energy
   7.5 Response to other ionising radiations
   7.6 Type and routine tests of performance
   7.7 Linearity of indication
8 Overload protection
   8.1 Requirements
   8.2 Method of test
9 Availability
   9.1 Warm-up time
   9.2 Power failure
10 Environmental conditions
   10.1 Temperature
   10.2 Relative humidity
   10.3 Atmospheric pressure
11 Power supply
   11.1 Voltage and frequency
   11.2 Electromagnetic compatibility
12 Storage
13 Documentation
   13.1 Certificate
   13.2 Operation and maintenance manual
   13.3 Operational instructions
   13.4 Type test report
Annex A (informative) Explanation of the derivation of
                      minimum detectable surface emission rate
                      formula

Defines mechanical and operational characteristics, minimum performance characteristics and general test procedures for personnel monitoring equipment. Applies to contamination warning assemblies, meters and monitors used for the monitoring of radioactive contamination on the surface of personnel whether they be clothed or not.

Committee
TC 45/SC 45B
DevelopmentNote
Supersedes IEC 61137. (12/2003) Stability Date: 2021. (09/2017)
DocumentType
Standard
Pages
79
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NEN IEC 61098 : 2004 Identical
VDE 0493-2-2 : 2008 Identical
DIN EN 61098 : 2008 Identical
UNE-EN 61098:2007 Identical
DS EN 61098 : 2007 Identical

00/715261 DC : DRAFT DEC 2000 IEC 60325 - ALPHA, BETA AND ALPHA-BETA CONTAMINATION METERS AND MONITORS
IEEE N323D-2002 American National Standard for Installed Radiation Protection Instrumentation

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 60050-394:2007 International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors
IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-12 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-12: TESTING AND MEASUREMENT TECHNIQUES - RING WAVE IMMUNITY TEST
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO 8769:2016 Reference sources Calibration of surface contamination monitors Alpha-, beta- and photon emitters
IEC 60777:1983 Terminology, quantities and units concerning radiation protection
IEC 60050-393:2003 International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts

View more information
$405.17
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more