Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 61223-2-5:1994

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Evaluation and routine testing in medical imaging departments - Part 2-5: Constancy tests - Image display devices
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

31-12-2021

Language(s)

English - French, Spanish, Castilian

Published date

30-03-1994

Introduction
1 Scope and object
   1.1 Scope
   1.2 Object
2 Normative references
3 Terminology
   3.1 Degree of requirements
   3.2 Use of terms
   3.3 Definitions
4 General aspects of CONSTANCY TESTS
   4.1 General conditions affecting test procedures
   4.2 Establishment of BASELINE VALUES
   4.3 Frequency of CONSTANCY TESTS
   4.4 Identification of equipment, instrumentation
        and test conditions
   4.5 Measured functional parameters
5 Test methods
   5.1 Summary
   5.2 Test equipment
   5.3 Test procedure
   5.4 Data evaluation
   5.5 Criteria to be applied
   5.6 Test report
   5.7 Action to be taken
   5.8 Frequency of testing
6 Statement of compliance
Figures
Annexes
A Terminology - Index of terms
B Example of a form for the standardized test report
C Guidance on action to be taken
D Rationale
E Bibliography - Reference test pattern
F IMAGE DISPLAY DEVICES in workstations: Environmental
   conditions

Applies to image display devices as used in diagnostic imaging systems. Describes a method to check, in terms of functional parameters the constancy of the quality of images reproduced by image display devices.

DevelopmentNote
Also numbered as BS EN 61223-2.5 and BS 7725-2.5(1995) (11/2005)
DocumentType
Standard
Pages
71
PublisherName
International Electrotechnical Committee
Status
Withdrawn

BS IEC 61223-2.10 : 2000 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-10 - CONSTANCY TESTS - X-RAY EQUIPMENT FOR MAMMOGRAPHY
CEI 62-112 : 2001 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2: CONSTANCY TESTS - EQUIPMENT FOR INTRA-ORAL DENTAL RADIOGRAPHY EXCLUDING DENTAL PANORAMIC EQUIPMENT
17/30362279 DC : 0 BS EN 61223-3-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-6: ACCEPTANCE AND CONSTANCY TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC TOMOSYNTHESIS MODE OF OPERATION OF MAMMOGRAPHIC X-RAY EQUIPMENT
BS IEC 61223-2.7 : 1999 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-7: CONSTANCY TESTS - EQUIPMENT FOR INTRA-ORAL DENTAL RADIOGRAPHY EXCLUDING DENTAL PANORAMIC EQUIPMENT
BS EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments Acceptance tests. Imaging performance of mammographic X-ray equipment
IEC 61223-2-10:1999 Evaluation and routine testing in medical imaging departments - Part 2-10: Constancy tests - X-ray equipment for mammography
CEI 62-113 : 2001 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2: CONSTANCY TESTS - EQUIPMENT FOR INDIRECT RADIOSCOPY AND INDIRECT
I.S. EN 61223-2-6:2007 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-6: CONSTANCY TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
EN 61223-3-3:1996 Evaluation and routine testing in medical imaging departments - Part 3-3: Acceptance tests - Imaging performance of X-ray equipment for digital subtraction angiography (DSA)
13/30246074 DC : DRAFT JAN 2014 BS ISO 12646 - GRAPHIC TECHNOLOGY - DISPLAYS FOR COLOUR PROOFING - CHARACTERISTICS AND VIEWING CONDITIONS
BS IEC 61223-2.9 : 1999 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-9 - CONSTANCY TESTS - EQUIPMENT FOR INDIRECT RADIOSCOPY AND INDIRECT RADIOGRAPHY
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
IEC 61223-3-3:1996 Evaluation and routine testing in medical imaging departments -Part 3-3: Acceptance tests - Imaging performance of X-ray equipmentfor digital subtraction angiography (DSA)
14/30246074 DC : 0 BS ISO 12646 - GRAPHIC TECHNOLOGY - DISPLAYS FOR COLOUR PROOFING - CHARACTERISTICS AND VIEWING CONDITIONS
02/122175 DC : DRAFT MAY 2002 BS ISO 12646 - GRAPHIC TECHNOLOGY - DISPLAYS FOR COLOUR PROOFING - CHARACTERISTICS AND VIEWING CONDITIONS
BS ISO 12646:2015 Graphic technology. Displays for colour proofing. Characteristics
I.S. EN 61223-3-2:2008 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-2: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF MAMMOGRAPHIC X-RAY EQUIPMENT
IEC 61223-3-2:2007 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment
BS EN 62563-1:2010 Medical electrical equipment. Medical image display systems Evaluation methods
PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
CEI 62-114 : 2001 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2: CONSTANCY TESTS - X-RAY EQUIPMENT FOR MAMMOGRAPHY
IEC 61223-2-9:1999 Evaluation and routine testing in medical imaging departments - Part 2-9: Constancy tests - Equipment for indirect radioscopy and indirect radiography
IEC 61223-2-7:1999 Evaluation and routine testing in medical imaging departments - Part 2-7: Constancy tests - Equipment for intra-oral dental radiography excluding dental panoramic equipment
I.S. EN 62563-1:2010 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL IMAGE DISPLAY SYSTEMS - PART 1: EVALUATION METHODS
EN 62563-1:2010/A1:2016 MEDICAL ELECTRICAL EQUIPMENT - MEDICAL IMAGE DISPLAY SYSTEMS - PART 1: EVALUATION METHODS (IEC 62563-1:2009/A1:2016)
IEC 61223-2-4:1994 Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras
IEC 61223-2-6:2006 Evaluation and routine testing in medical imaging departments ­ - Part 2­-6: Constancy tests ­ imaging performance of computed tomography X-ray equipment
IEC 62563-1:2009+AMD1:2016 CSV Medical electrical equipment - Medical image display systems - Part1: Evaluation methods
BS EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments Constancy tests. Imaging performance of computed tomography X-ray equipment
ISO 12646:2015 Graphic technology — Displays for colour proofing — Characteristics
EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments - Part 2-6: Constancy tests - Imaging performance of computed tomography X-ray equipment
EN 61223-3-2:2008 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment

IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
IEC 61223-2-4:1994 Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras

View more information
$575.72
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more