IEC 61347-2-8:2000+AMD1:2006 CSV
Current
The latest, up-to-date edition.
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
14-03-2006
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Capacitors and other components
4.2 Thermally protected ballasts
5 General notes on tests
6 Classification
7 Marking
7.1 Mandatory markings
7.2 Information to be provided, if applicable
7.3 Other information
8 Protection against accidental contact with live
parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Ballast heating
14.1 Pre-test, checks and measures
14.2 Voltage across capacitors
14.3 Ballast heating test
15 High-voltage impulse testing
16 Fault conditions
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections
20 Resistance to heat, fire and tracking
21 Resistance to corrosion
22 No-load output voltage
Annexes
Annex A (normative) Test to establish whether a conductive
part is a live part which may cause an
electric shock
Annex B (normative) Particular requirements for thermally
protected lamp controlgear
Annex C (normative) Particular requirements for electronic
lamp controlgear with means of protection
against overheating
Annex D (normative) Requirements for carrying out the heating
tests of thermally protected lamp controlgear
Annex E (normative) Use of constant S other than 4 500 in
t[w] tests
Annex F (normative) Draught-proof enclosure
Annex G (normative) Explanation of the derivation of the values
of pulse voltages
Annex H (normative) Tests
Annex I (normative) Method for selection of varistors
Annex J (informative) Explanation of ballast temperatures
Annex K (normative) Additional requirements for
built-in magnetic ballasts with
double or reinforced insulation
Bibliography
This part of IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. This consolidated version consists of the first edition (2000) and its amendment 1 (2006). Therefore, no need to order amendment in addition to this publication. The contents of the corrigendum of August 2012 have been included in this copy.
Committee |
TC 34/SC 34C
|
DevelopmentNote |
Supersedes IEC 60920 (01/2001) Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
43
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
GOST R IEC 61347-2-8 : 2011 | Identical |
NEN EN IEC 61347-2-8 : 2001 AMD 1 2006 | Identical |
PN EN 61347-2-8 : 2003 AC 2011 | Identical |
SANS 61347-2-8 : 1.01ED 2007(R2012) | Identical |
AS/NZS 61347.2.8:2003 | Identical |
SN EN 61347-2-8 : 2001 AMD 1 2006 | Identical |
VDE 0712-38 : 2006 COR 2 2013 | Identical |
DIN EN 61347-2-8 : 2006 COR 2 2013 | Identical |
BS EN 61347-2-8 : 2001 | Identical |
NF EN 61347-2-8 : 2001 AMD 1 2006 | Identical |
UNE-EN 61347-2-8:2002 | Identical |
EN 62442-1:2011/A11:2017 | ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 1: CONTROLGEAR FOR FLUORESCENT LAMPS - METHOD OF MEASUREMENT TO DETERMINE THE TOTAL INPUT POWER OF CONTROLGEAR CIRCUITS AND THE EFFICIENCY OF THE CONTROLGEAR |
UNE-EN 61347-2-9:2013 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
BS EN 60921:2004 | Ballasts for tubular fluorescent lamps. Performance requirements |
16/30344762 DC : 0 | BS EN 62442-1 ED1.0/A1 - ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 1: CONTROLGEAR FOR FLUORESCENT LAMPS - METHOD OF MEASUREMENT TO DETERMINE THE TOTAL INPUT POWER OF CONTROLGEAR CIRCUITS AND THE EFFICIENCY OF THE CONTROLGEAR |
I.S. EN 61347-2-9:2013 | LAMP CONTROLGEAR - PART 2-9: PARTICULAR REQUIREMENTS FOR ELECTROMAGNETIC CONTROLGEAR FOR DISCHARGE LAMPS (EXCLUDING FLUORESCENT LAMPS) (IEC 61347-2-9:2012 (EQV)) |
NF EN 60079-15 : 2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
I.S. EN 61199:2011 | SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS |
I.S. EN 61048:2006 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS |
I.S. EN 60079-15:2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
BS EN 61347-2-9:2013 | Lamp controlgear Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
I.S. EN 61347-1:2015 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
DIN EN 12665:2016-09 (Draft) | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
IEC 60079-7:2015+AMD1:2017 CSV | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
EN IEC 60079-7:2015/A1:2018 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017) |
BS EN 61347-1:2015 | Lamp controlgear General and safety requirements |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
EN 61558-2-20:2011 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-20: Particular requirements and tests for small reactors |
EN 61199:2011/A2:2015 | SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61199:2011/A2:2014) |
EN 62776:2015 | Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications |
EN 61347-2-9:2013 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
03/103715 DC : 0 | IEC 60730-2-3 ED.2 - AUTOMATIC CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2: PARTICULAR REQUIREMENTS - SECTION 3: THERMAL PROTECTORS FOR BALLASTS FOR TUBULAR FLUORESCENT LAMPS |
NF EN 60730-2-3 : 2008 | AUTOMATIC CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-3: PARTICULAR REQUIREMENTS FOR THERMAL PROTECTORS FOR BALLASTS FOR TUBULAR FLUORESCENT LAMPS |
16/30342256 DC : 0 | BS EN 50107-3 - PRODUCT STANDARD COVERING LUMINOUS SIGNS WITH DISCHARGE LAMPS AND/OR LED (LIGHT EMITTING DIODES) AND/OR EL (ELECTROLUMINESCENT) LIGHTSOURCES WITH A NOMINAL VOLTAGE NOT EXCEEDING 1000 V, WITH THE EXCLUSION OF GENERAL LIGHTING, TRAFFIC- OR EMERGENCY RELATED PURPOSE |
09/30206024 DC : 0 | BS EN 61199 - SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS |
BS EN 60079-7 : 2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
I.S. EN 60921:2005 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
CSA C22.2 No. 60079-7 : 2016 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
CCS GUIDELINE E-08 : 2017 | LUMINAIRES |
CSA C22.2 No. 60079-15 : 2016 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
CEI EN 60079-15 : 2012 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
BIS IS/IEC 60079-15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION 'N' ELECTRICAL APPARATUS |
11/30252196 DC : 0 | BS EN 61347-1:2008 + A2 - LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
BS EN 61558-2-20:2011 | Safety of transformers, reactors, power supply units and combinations thereof Particular requirements and tests for small reactors |
14/30278882 DC : 0 | BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
BS EN 60730-2-3:2007 | Automatic electrical controls for household and similar use Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps |
CEI EN 61558-2-20 : 2012 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - PART 2-20: PARTICULAR REQUIREMENTS AND TESTS FOR SMALL REACTORS |
06/30137993 DC : DRAFT OCT 2006 | IEC 62442-1 - LAMP CONTROLGEAR - PART 1: BALLASTS FOR FLUORESCENT LAMPS - METHOD OF MEASUREMENT TO DETERMINE ENERGY CONSUMPTION |
I.S. EN 62776:2015 | DOUBLE-CAPPED LED LAMPS DESIGNED TO RETROFIT LINEAR FLUORESCENT LAMPS - SAFETY SPECIFICATIONS |
I.S. EN 61347-2-1:2004 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) |
I.S. EN 62442-1:2011 | ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 1: CONTROLGEAR FOR FLUORESCENT LAMPS - METHOD OF MEASUREMENT TO DETERMINE THE TOTAL INPUT POWER OF CONTROLGEAR CIRCUITS AND THE EFFICIENCY OF THE CONTROLGEAR |
IEC 61347-1 REDLINE : 3ED 2015 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
BS EN 60079-15:2010 | Explosive atmospheres Equipment protection by type of protection \'n\' |
PREN 50107-3 : DRAFT 2016 | PRODUCT STANDARD COVERING LUMINOUS SIGNS WITH DISCHARGE LAMPS AND/OR LED (LIGHT EMITTING DIODES) AND/OR EL (ELECTROLUMINESCENT) LIGHTSOURCES WITH A NOMINAL VOLTAGE NOT EXCEEDING 1000 V, WITH THE EXCLUSION OF GENERAL LIGHTING, TRAFFIC- OR EMERGENCY RELATED PURPOSE |
UNI EN 12665 : 2011 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
I.S. EN 61558-2-20:2011 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - PART 2-20: PARTICULAR REQUIREMENTS AND TESTS FOR SMALL REACTORS |
UNE-EN 61347-1:2016 | Lamp controlgear - Part 1: General and safety requirements |
UL 1993:5ED 2017-01 | Self-Ballasted Lamps and Lamp Adapters |
C22.2 NO. 1993-17 | Self-ballasted lamps and lamp adapters (Trinational standard with NMX-J-578/1-ANCE and UL 1993) |
04/300396 DC : DRAFT JAN 2004 | IEC 61347-1 A2 ED.1 - LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
BS EN 61048 : 2006 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS |
13/30277819 DC : 0 | BS EN 62776 ED 1.0 - DOUBLE-CAPPED LED LAMPS FOR GENERAL LIGHTING SERVICES - SAFETY SPECIFICATIONS |
CEI EN 61347-2-9 : 2013 | LAMP CONTROLGEAR - PART 2-9: PARTICULAR REQUIREMENTS FOR ELECTROMAGNETIC CONTROLGEAR FOR DISCHARGE LAMPS (EXCLUDING FLUORESCENT LAMPS) |
CEI EN 61347-1 : 2016 | LAMP CONTROLGEAR - PART 1: GENERAL AND SAFETY REQUIREMENTS |
NF EN 60921 : 2005 AMD 1 2006 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
GOST R 52350.15 : 2005 | ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 15: CONSTRUCTION, TEST AND MARKING OF TYPE OF PROTECTION "N" ELECTRICAL APPARATUS |
BS EN 61199 : 2011 | SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS |
CEI EN 60730-2-3 : 2008 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2: PARTICULAR REQUIREMENTS FOR THERMAL PROTECTORS FOR BALLASTS FOR TUBULAR FLUORESCENT LAMPS |
I.S. EN 61549:2003 | MISCELLANEOUS LAMPS (IEC 61549:2003 (EQV)) |
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV | Single-capped fluorescent lamps - Safety specifications |
IEC 61549:2003+AMD1:2005 CSV | Miscellaneous lamps |
UNE-EN 12665:2012 | Light and lighting - Basic terms and criteria for specifying lighting requirements |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 60921:2004+AMD1:2006 CSV | Ballasts for tubular fluorescent lamps - Performance requirements |
BS EN 12665:2011 | Light and lighting. Basic terms and criteria for specifying lighting requirements |
IEC 61558-2-20:2010 | Safety of transformers, reactors, power supply units and combinations thereof - Part 2-20: Particular requirements and tests for small reactors |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
UNE-EN 61549:2004 | Miscellaneous lamps |
UNE-EN 60079-15:2013 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
UNE-EN 61199:2012 | Single-capped fluorescent lamps - Safety specifications |
07/30168628 DC : 0 | BS EN 60079-15 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
BS EN 62776:2015 | Double-capped LED lamps designed to retrofit linear fluorescent lamps. Safety specifications |
08/30186575 DC : DRAFT JULY 2008 | BS EN 60079-15 ED. 4 - EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION "N" |
BS EN 62442-1:2011 | Energy performance of lamp controlgear Controlgear for fluorescent lamps. Method of measurement to determine the total input power of controlgear circuits and the efficiency of the controlgear |
I.S. EN 60079-7:2015 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' |
UNE-EN 61558-2-20:2012 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V -- Part 2-20: Particular requirements and tests for small reactors |
BS EN 61549 : 2003 | MISCELLANEOUS LAMPS |
UNE-EN 62776:2015 | Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications |
UNE-EN 60079-7:2016 | Explosive atmospheres - Part 7: Equipment protection by increased safety "e" |
CEI EN 62442-1 : 2012 | ENERGY PERFORMANCE OF LAMP CONTROLGEAR - PART 1: CONTROLGEAR FOR FLUORESCENT LAMPS - METHOD OF MEASUREMENT TO DETERMINE THE TOTAL INPUT POWER OF CONTROLGEAR CIRCUITS AND THE EFFICIENCY OF THE CONTROLGEAR |
I.S. EN 12665:2011 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
I.S. EN 60730-2-3:2007 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-3: PARTICULAR REQUIREMENTS FOR THERMAL PROTECTORS FOR BALLASTS FOR TUBULAR FLUORESCENT LAMPS |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
EN 61048:2006/A1:2016 | AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006/A1:2015) |
EN 60921:2004/A1:2006 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
EN 60730-2-3:2007 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-3: PARTICULAR REQUIREMENTS FOR THERMAL PROTECTORS FOR BALLASTS FOR TUBULAR FLUORESCENT LAMPS |
EN 61549:2003/A3:2012 | MISCELLANEOUS LAMPS (IEC 61549:2003/A3:2012) |
EN 61347-2-1:2001/A2:2014 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) (IEC 61347-2-1:2000/A2:2013) |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 61048:2006+AMD1:2015 CSV | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 61049:1991 | Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.