IEC 61811-54:2002

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electromechanical all-or-nothing relays - Part 54: Blank detail specification - Electromechanical all-or-nothing telecom relays of assessed quality - Two change-over contacts, 15 mm x 7,5 mm base
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

28-01-2015

Language(s)

English, English - French

Published date

12-03-2002

FOREWORD
1 General
   1.1 Scope
   1.2 Normative references
   1.3 Front page of the detail specification
2 Characteristic values of the relay
   2.1 General data
   2.2 Construction of IECQ type designation (ordering
        information)
   2.3 Coil data
   2.4 Contact data
        2.4.1 Electrical endurance and switching frequency
        2.4.2 Static contact-circuit resistance
        2.4.3 Mechanical endurance
        2.4.4 Timing (without suppression device)
   2.5 Mounting
   2.6 Environmental data
   2.7 Package of relays for automatic handling
        (if applicable)
3 Qualification approval procedures
4 Quality conformance inspection
   4.1 Formation of inspection lots
   4.2 Intervals between tests
5 Marking and documentation
   5.1 Marking of the relay
   5.2 Marking of the package
   5.3 Documentation
6 Annexes
7 Tests
   7.1 Standard conditions for testing
   7.2 Mounting of test specimens during the test
   7.3 General conditions for testing
8 Ordering information
9 Relay reliability - Failure rate data (optional)
Tables

IEC 61811-54:2002 Is a blank detail specification applicable to electromechanical all-or-nothing telecom relays of assessed quality. Selects the appropriate methods of test to be used in detail specifications and contains basic test schedules to be used in the preparation of such specifications.

Committee
TC 94
DevelopmentNote
Stability Date: 2014. (10/2012) A Bilingual edition has been published on 28/04/2014. (04/2014)
DocumentType
Standard
Pages
31
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

HD 323.2.20 : 200S3 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 61811-50:2002 Electromechanical all-or-nothing relays - Part 50: Sectional specification - Electromechanical all-or-nothing telecom relays of assessed quality
IEC 60068-2-20:2008 Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads
CECC 00802 : 1994 GUIDANCE DOCUMENT: CECC STANDARD METHOD FOR THE SPECIFICATION OF SURFACE MOUNTING (SMDs) OF ASSESSED QUALITY
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
EN 60068-2-17:1994 Environmental testing - Part 2: Tests - Test Q: Sealing
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
IEC 60255-14:1981 Electrical relays. Part 14: Endurance tests for electrical relay contacts - Preferred values for contact loads
IEC 61811-50:2002 Electromechanical all-or-nothing relays - Part 50: Sectional specification - Electromechanical all-or-nothing telecom relays of assessed quality
IEC 61709 : 3.0 ELECTRIC COMPONENTS - RELIABILITY - REFERENCE CONDITIONS FOR FAILURE RATES AND STRESS MODELS FOR CONVERSION
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
IEC 61811-1:2015 Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification
EN 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
EN 60695-2-2:1994/A1:1995 FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST
EN 61811-1:2015 Electromechanical telecom elementary relays of assessed quality - Part 1: Generic specification and blank detail specification
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests

View more information
$575.72
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more