IEC 62040-2:2016
Current
The latest, up-to-date edition.
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
25-11-2016
IEC 62040-2:2016 is available as IEC 62040-2:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62040-2:2016 is a type test product standard for electromagnetic compatibility (EMC) and applies to movable, stationary, fixed or built-in, pluggable and permanently connected UPS for use in low-voltage distribution systems with an environment being either residential, commercial, light industrial or industrial, which deliver output voltage with port voltages not exceeding 1 500 V DC or 1 000 V AC and which include an energy storage device. This edition includes the following significant technical changes with respect to the previous edition:
a) the inclusion of network port limits in Table 1, Table 2 and Annex C for the sake of consistency with other standards;
b) a change of quasi-peak limit for category C3 UPS in Table 2 for the sake of consistency with other standards;
c) a clarification in Table 4 about the performance criteria for immunity tests;
d) a revision of some test configurations in Annex A.
The contents of the Interpretation sheet 1 of June 2018 have been included in this copy.
Committee |
TC 22/SC 22H
|
DevelopmentNote |
Stability Date: 2021. (11/2016)
|
DocumentType |
Standard
|
Pages |
95
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
CEI EN IEC 62040-2 : 2019 | Identical |
AS IEC 62040.2:2019 | Identical |
OVE EN IEC 62040-2: 2019 05 01 | Identical |
DIN EN IEC 62040-2 : 2019-04 | Identical |
EN IEC 62040-2:2018 | Identical |
VDE 0558-520:2019-04 | Identical |
PN-EN IEC 62040-2:2019 | Identical |
IS 16242 : Part 2 : 2020 | Identical |
UNE-EN IEC 62040-2:2018 | Identical |
BS EN IEC 62040-2:2018 | Identical |
DIN EN 62040-2 : 2006 COR 1 2007 | Identical |
OVE/ONORM EN 62040-2 : 2006 | Identical |
NEN EN IEC 62040-2 : 2006 C1 2011 | Identical |
BS EN 60745-2-17:2010 | Identical |
CEI EN 62040-2 : 2006 | Identical |
SANS 62040-2 : 2ED 2007(R2013) | Identical |
I.S. EN 62040-2:2006 | Identical |
SN EN 62040-2 : 2006 | Identical |
EN 62040-2:2006/corrigendum:2006 | Identical |
NF EN 62040-2 : 2006 | Identical |
BS EN 62040-2:2006 | Identical |
VDE 0558-520 : 2006 COR 1 2007 | Identical |
PN EN 62040-2 : 2008 | Identical |
BIS IS 16242-2 : 2014 | Identical |
14/30297921 DC : 0 | BS EN 62040-5-3 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS FOR D.C. UPS |
CEI EN 62040-4 : 2014 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 4: ENVIRONMENTAL ASPECTS - REQUIREMENTS AND REPORTING |
BS EN 62040-1 : 2008 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS |
IEEE 650-2006 | IEEE Standard for Qualification of Class 1E Static Battery Chargers and Inverters for Nuclear Power Generating Stations |
06/30158289 DC : 0 | BS EN 62040-1 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS |
14/30244780 DC : 0 | BS ISO 19859 - GAS TURBINE APPLICATIONS - REQUIREMENTS FOR POWER GENERATION |
EN 62040-4:2013 | Uninterruptible power systems (UPS) - Part 4: Environmental aspects - Requirements and reporting |
EN 62040-5-3:2017 | Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements |
EN 62040-1-2:2003/corrigendum:2004 | |
06/30157062 DC : 0 | BS EN 62310-3 - STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
BS EN 62282-5-1:2012 | Fuel cell technologies Portable fuel cell power systems. Safety |
BS EN 62040-5-3:2017 | Uninterruptible power systems (UPS) DC output UPS. Performance and test requirements |
PD IEC/TS 62578:2015 | Power electronics systems and equipment. Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz |
BS EN 62920:2017 | Photovoltaic power generating systems. EMC requirements and test methods for power conversion equipment |
11/30231694 DC : 0 | BS EN 62040-4 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 4: ENVIRONMENTAL ASPECTS - REQUIREMENTS AND REPORTING |
BS EN 62040-1-1:2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas |
I.S. EN 62310-1:2005 | STATIC TRANSFER SYSTEMS (STS) - PART 1: GENERAL AND SAFETY REQUIREMENTS |
I.S. EN 62040-5-3:2017 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS |
BIS IS 16242-1 : 2014 AMD 1 2018 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS |
I.S. EN 60146-1-1:2010 | SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
I.S. EN 62040-1-2:2004 | |
I.S. EN 62040-3:2011 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS |
I.S. EN 62040-1:2008 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008 (EQV)) |
ISO 19859:2016 | Gas turbine applications Requirements for power generation |
I.S. EN ISO 14224:2016 | PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES - COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT (ISO 14224:2016) |
BS IEC 61892-3:2012 | Mobile and fixed offshore units. Electrical installations Equipment |
I.S. EN 62920:2017 | PHOTOVOLTAIC POWER GENERATING SYSTEMS - EMC REQUIREMENTS AND TEST METHODS FOR POWER CONVERSION EQUIPMENT |
EN 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
I.S. EN 62041:2010 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - EMC REQUIREMENTS |
IEC 61892-3:2012 | Mobile and fixed offshore units - Electrical installations - Part 3: Equipment |
ISO 14224:2016 | Petroleum, petrochemical and natural gas industries Collection and exchange of reliability and maintenance data for equipment |
IEC 62282-5-1:2012 | Fuel cell technologies - Part 5-1: Portable fuel cell power systems - Safety |
BS EN 62310-3:2008 | Static transfer systems (STS) Method for specifying performance and test requirements |
BS EN 62040-4:2013 | Uninterruptible power systems (UPS) Environmental aspects. Requirements and reporting |
CEI EN 62041 : 2012 | SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND COMBINATIONS THEREOF - EMC REQUIREMENTS |
BS EN 62041:2010 | Safety of transformers, reactors, power supply units and combinations thereof. EMC requirements |
I.S. EN 62040-1-1:2004 | |
BS EN 62040-3:2011 | Uninterruptible power systems (UPS) Method of specifying the performance and test requirements |
IEC TS 62578:2015 | Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz |
I.S. EN 62310-3:2008 | STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD FOR SPECIFYING PERFORMANCE AND TEST REQUIREMENTS |
CEI EN 62310-1 : 2006 | STATIC TRANSFER SYSTEMS (STS) - PART 1: GENERAL AND SAFETY REQUIREMENTS |
CEI EN 60146-1-1 : 2013 | SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
I.S. EN 62040-4:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 4: ENVIRONMENTAL ASPECTS - REQUIREMENTS AND REPORTING (IEC 62040-4:2013 (EQV)) |
IEC 62040-1:2017 EXV | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: SAFETY REQUIREMENTS |
IEC 62310-3:2008 | Static transfer systems (STS) - Part 3: Method for specifying performance and test requirements |
IEC 62040-1-1:2002 | Uninterruptible power systems (UPS) - Part 1-1: General and safety requirements for UPS used in operator access areas |
IEC 62040-5-3:2016 | Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements |
IEC 62040-4:2013 | Uninterruptible power systems (UPS) - Part 4: Environmental aspects - Requirements and reporting |
UNE-EN 62282-5-1:2013 | Fuel cell technologies - Part 5-1: Portable fuel cell power systems - Safety |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 62040-1-2:2002 | Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS used in restricted access locations |
IEC 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
BS ISO 19859:2016 | Gas turbine applications. Requirements for power generation |
EN 62310-3:2008 | Static transfer systems (STS) - Part 3: Method for specifying performance and test requirements |
06/30156472 DC : DRAFT SEP 2006 | BS EN 60146-1-1 - SEMICONDUCTOR CONVERTERS - GENERAL REQUIREMENTS AND LINE COMMUTATED CONVERTERS - PART 1-1: SPECIFICATION OF BASIC REQUIREMENTS |
DD IEC TS 62578 : DRAFT 2009 | POWER ELECTRONICS SYSTEMS AND EQUIPMENT - OPERATION CONDITIONS AND CHARACTERISTICS OF ACTIVE INFEED CONVERTER APPLICATIONS |
BS EN 60146-1-1:2010 | Semiconductor converters. General requirements and line commutated converters Specification of basic requirements |
NF EN 62040-1 : 2009 AMD 1 2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS |
CEI EN 62310-3 : 2010 | STATIC TRANSFER SYSTEMS (STS) - PART 3: METHOD FOR SPECIFYING PERFORMANCE AND TEST REQUIREMENTS |
UNE-EN 62041:2011 | Safety of transformers, reactors, power supply units and combinations thereof - EMC requirements |
EN 62920:2017 | Photovoltaic power generating systems - EMC requirements and test methods for power conversion equipment |
EN 62040-1:2008/A1:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013) |
16/30354067 DC : 0 | BS EN 62282-5-100 - FUEL CELL TECHNOLOGIES - PART 5-100: PORTABLE FUEL CELL POWER SYSTEMS - SAFETY |
BS EN 62040-1-2:2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations |
BS EN ISO 14224:2016 | Petroleum, petrochemical and natural gas industries. Collection and exchange of reliability and maintenance data for equipment |
EN 62282-5-1:2012 | FUEL CELL TECHNOLOGIES - PART 5-1: PORTABLE FUEL CELL POWER SYSTEMS - SAFETY (IEC 62282-5-1:2012) |
EN 62041:2010 | Safety of transformers, reactors, power supply units and combinations thereof - EMC requirements |
EN 60146-1-1:2010 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
EN 62040-1-1:2003/corrigendum:2004 | |
EN 62310-1:2005 | Static transfer systems (STS) - Part 1: General and safety requirements |
CEI 18-58 : 2013 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
IEC 61000-4-8 : 2.0 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 16-2-1:2014 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61000-4-6 : 4.0 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61000-3-2 : 4.0 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE) |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.