Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 62153-4-7:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance ZT and screening attenuation aS or coupling attenuation aC of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

23-07-2021

Published date

09-12-2015

IEC 62153-4-7:2015 describes a triaxial method, suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and multicore cable assemblies. For the measurement of transfer impedance and screening- or coupling attenuation, only one test set-up is needed. This edition includes the following significant technical changes with respect to the previous edition:
The document is revised and updated. The changes of the revised IEC 62153-4-3:2013, and IEC 62153-4-4:2015, are included. Measurements can be achieved now with mismatch at the generator site, impedance matching devices are not necessary. The contents of the corrigendum of April 2016 have been included in this copy.

Committee
TC 46
DevelopmentNote
Stability Date: 2020. (05/2018)
DocumentType
Standard
Pages
53
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

BS EN 60966-2-5:2017 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
CEI EN 60966-2-6 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS
SAE USCAR 37 : 2008 HIGH VOLTAGE CONNECTOR PERFORMANCE SUPPLEMENT TO SAE/USCAR-2
EN 60966-2-5:2017 Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
EN 60966-2-4:2016 Radio Frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
IEC 62153-4-10:2015 Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method
I.S. EN 60966-2-6:2017 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-6: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-24 CONNECTORS
BS EN 60966-2-6:2017 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
13/30292666 DC : 0 BS EN 60966-2-4 - DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61196-2 CONNECTORS
13/30292675 DC : 0 BS EN 60966-2-6 - DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61196-24 CONNECTORS
BS EN 60966-2-7:2016 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors
13/30292670 DC : 0 BS EN 60966-2-5 - DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61196-2 CONNECTORS
13/30279876 DC : 0 BS EN 62153-4-15 ED.1 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-15: ELECTROMAGNETIC COMPATIBILITY (EMC) - TEST METHOD FOR MEASURING TRANSFER IMPEDANCE AND SCREENING ATTENUATION - OR COUPLING ATTENUATION WITH TRIAXIAL CELL
BS EN 60966-2-4:2009 Radio frequency and coaxial cable assemblies Detail specification for cable assemblies for radio and TV receivers. Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
IEC TS 62153-4-1:2014 Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements
IEC 62153-4-15:2015 Metallic communication cable test methods - Part 4-15: Electromagnetic compatibility (EMC) - Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with triaxial cell
BS IEC 62153-4-10:2015 Metallic communication cable test methods Electromagnetic compatibility (EMC). Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets. Double coaxial test method
BS IEC 62153-4-15:2015 Metallic Communication Cable test methods Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation or coupling attenuation with triaxial cell
SAE USCAR 17 : 2013 PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYSTEMS
CEI EN 60966-2-4 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS
I.S. EN 60966-2-5:2017 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS
IEC 60966-2-7:2015 Radio frequency and coaxial cable asemblies - Part 2-7: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors
IEC 60966-2-6:2016 Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
IEC 60966-2-5:2016 Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
IEC 60966-2-4:2016 Radio frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
I.S. EN 60966-2-4:2016 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-4: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-2 CONNECTORS
13/30292984 DC : 0 BS EN 62153-4-10 ED2 - METALLIC COMMUNICATION CABLE TEST METHODS - PART 4-10: ELECTROMAGNETIC COMPATIBILITY (EMC) - SHIELDED SCREENING ATTENUATION TEST METHOD FOR MEASURING THE SCREENING EFFECTIVENESS OF FEED-THROUGHS AND ELECTROMAGNETIC GASKETS DOUBLE COAXIAL METHOD
13/30291609 DC : 0 BS EN 60966-1 - RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 1: GENERIC SPECIFICATION - GENERAL REQUIREMENTS AND TEST METHODS
I.S. EN 60966-2-7:2016 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-7: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 3000 MHZ, IEC 61169-47 CONNECTORS
CEI EN 60966-2-5 : 2010 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES - PART 2-5: DETAIL SPECIFICATION FOR CABLE ASSEMBLIES FOR RADIO AND TV RECEIVERS - FREQUENCY RANGE 0 MHZ TO 1000 MHZ, IEC 61169-2 CONNECTORS
EN 60966-2-6:2017 Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
EN 60966-2-7:2016 Radio frequency and coaxial cable assemblies - Part 2-7: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-47 connectors

IEC 62153-4-3:2013 Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) - Surface transfer impedance - Triaxial method
IEC 62153-4-15:2015 Metallic communication cable test methods - Part 4-15: Electromagnetic compatibility (EMC) - Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with triaxial cell
IEC 62153-4-4:2015 Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) - Test method for measuring of the screening attenuation as up to and above 3 GHz, triaxial method
IEC 62153-4-8:2006 Metallic communication cable test methods - Part 4-8: Electromagnetic compatibility (EMC) - Capacitive coupling admittance
IEC TS 62153-4-1:2014 Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) - Introduction to electromagnetic screening measurements
IEC 62153-4-9:2008 Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method
IEC 62153-4-10:2015 Metallic communication cable test methods - Part 4-10: Electromagnetic compatibility (EMC) - Transfer impedance and screening attenuation of feed-throughs and electromagnetic gaskets - Double coaxial test method

View more information
$659.58
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more