IEC 62271-106:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
19-08-2011
FOREWORD
1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of contactors and motor-starters
for service
9 Information to be given with enquiries, tenders and orders
10 Transport, storage, installation, operation and maintenance
11 Safety
Annex A (normative) - Records and reports of type tests for
making, breaking and short-time current performance
Annex B (normative) - Tolerances
Annex C (informative) - List of symbols and abbreviations
Bibliography
IEC 62271-106:2011 is applicable to a.c. contactors and/or contactor-based controllers and motor-starters designed for indoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V but not exceeding 24 000 V.It is applicable only to three-pole devices for use in three-phase systems, and single-pole devices for use in single-phase systems. Two-pole contactors and starters for use in single-phase systems are subject to agreement between manufacturer and user. This standard cancels and replaces the second edition of IEC 60470 published in 1999. It constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60470:1999:
- Scope and object: The voltage range covered by the standard was expanded from 12 kV to 24 kV. Overload relay calibration and testing is not covered by this standard.
- 3 Terms and definitions: Added definitions for capacitor switching classes.
- 4.1 Rated voltage: Added 15, 17,5 and 24 kV as standard voltage values.
- 4.109.2 Starting duty of reduced-voltage starters: Added ratings for autotransformer and reactor starters (was in the testing section).
- 4.112 Rated capacitive switching currents: Added capacitor switching current ratings.
- 5.101 Protective relays: Removed the requirements for overload relays. This section is obsolete since there are only a few MV starters fitted with thermal overload relays and electronic relays have their own standards.
- 6.2.5 Application of the test voltage and test conditions (former 6.2.2 b)): Changed wording of requirement for impulse across the open gap of vacuum contactors.
- 6.4.2 Auxiliary circuits: The requirement for resistance checks of auxiliary circuits was deleted.
- 6.5.5.104 Temperature rise of the auto transformer or reactor for two step auto transformer or reactor starters: Reworded to transfer ratings to subclause 4.109.2.
- 6.102.9 Condition following making and breaking tests: Gave specific direction as to what the tolerance should be based on where the resistance was to be checked.
- 6.104 Short-circuit current making and breaking tests: Clarified test conditions for short-circuit testing.
- 6.109 Capacitive current switching tests: Added capacitive current switching tests.
- Annex B: Added Table B.1 - Tolerances on test quantities for type test.The contents of the corrigendum of February 2014 have been included in this copy.
DevelopmentNote |
Supersedes IEC 60470. To be used in conjunction with IEC 62271-1. (08/2011) Stability Date: 2020. (11/2017)
|
DocumentType |
Standard
|
Pages |
167
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 62271-106:2012 | Identical |
NF EN 62271-106 : 2012 | Identical |
NBN EN 62271-106 : 2011 | Identical |
NEN EN IEC 62271-106 : 2011 C1 2014 | Identical |
I.S. EN 62271-106:2011 | Identical |
PN EN 62271-106 : 2011 | Identical |
SANS 62271-106 : 1ED 2012(R2014) | Identical |
SAC GB/T 14808 : 2001 | Identical |
VDE 0671-106 : 2012 | Identical |
DIN EN 62271-106 : 2012 | Identical |
BS EN 62271-106:2011 | Identical |
EN 62271-106:2011 | Identical |
UNE-EN 62271-106:2011 | Identical |
15/30324300 DC : 0 | BS EN 62271-110 ED 4 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING |
PD IEC/TR 63042-100:2016 | UHV AC transmission systems General information |
I.S. EN IEC 62271-110:2018 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING |
I.S. EN 62271-110:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING (IEC 62271-110:2012 (EQV) + CORRIGENDUM OCT. 2012 (EQV)) |
EN 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-110:2017 RLV | High-voltage switchgear and controlgear - Part 110: Inductive load switching |
IEC 62271-110 REDLINE : 4ED 2017 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING |
BS EN 62271-110:2012 | High-voltage switchgear and controlgear Inductive load switching |
CEI EN 62271-201 : 2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 61892-3:2012 | Mobile and fixed offshore units - Electrical installations - Part 3: Equipment |
EN IEC 62271-110:2018/AC:2018-03 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING (IEC 62271-110:2017/COR1:2017, IEC 62271-110:2017/COR2:2018 |
IEC 62505-2:2016 | Railway applications - Fixed installations - Particular requirements for AC switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
IEC TR 62655:2013 | Tutorial and application guide for high-voltage fuses |
IEC 62271-110:2017 | High-voltage switchgear and controlgear - Part 110: Inductive load switching |
PD IEC/TR 62655:2013 | Tutorial and application guide for high-voltage fuses |
CEI EN 62271-110 : 2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING |
IEC TR 63042-100:2016 | UHV AC transmission systems - Part 100: General information |
UNE-EN 62271-201:2015 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
BS EN 62271-201:2014 | High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
BS IEC 61892-3:2012 | Mobile and fixed offshore units. Electrical installations Equipment |
10/30228779 DC : 0 | BS EN 62271-110 ED3 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 110: INDUCTIVE LOAD SWITCHING |
IEEE 45.6-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Electrical Testing |
I.S. EN 62271-201:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
CEI 18-58 : 2013 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 3: EQUIPMENT |
UNE-EN 62271-110:2013 | High-voltage switchgear and controlgear - Part 110: Inductive load switching |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 62271-110:2017 | High-voltage switchgear and controlgear - Part 110: Inductive load switching |
IEC 61812-1:2011 | Time relays for industrial and residential use - Part 1: Requirements and tests |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60644:2009 | Specification for high-voltage fuse-links for motor circuit applications |
IEC 60947-5-1 : 4.0 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES |
IEC 60282-1:2009+AMD1:2014 CSV | High-voltage fuses - Part 1: Current-limiting fuses |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
IEC 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
AS 62271.110:2019 | High-voltage switchgear and controlgear Inductive load switching (IEC 62271-110:2017 (ED 4.0)/COR 1:2017/COR 2:2018, MOD) |
IEC 61230:2008 | Live working - Portable equipment for earthing or earthing and short-circuiting |
IEC 60255-8:1990 | Electrical relays - Part 8: Thermal electrical relays |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.