Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above - Fluid-filled and extruded insulation cables - Fluid-filled and dry type cable-terminations
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

09-08-2007

Published date

29-07-1999

Foreword
1 Scope
2 Normative references
3 Definitions
4 Limits of supply
5 Rating
      5.1 Rated voltage
      5.2 Number of phases in one enclosure
      5.3 Rated insulation level
      5.4 Rated normal current and temperature rise
      5.5 Rated short-time and peak withstand currents
             and rated duration of short circuit
6 Design and construction requirements
      6.1 Pressure withstand requirements
      6.2 Mechanical forces on cable-terminations
7 Standard dimensions
      7.1 Fluid-filled cable-terminations
      7.2 Dry type cable-terminations
8 Tests
      8.1 General
      8.2 Dielectric type tests
             8.2.1 Dielectric type tests of cable-
                      terminations
             8.2.2 Dielectric type test of cable
                      connection enclosures
      8.3 Tests after cable installation
9 Information to be given with enquiries, tenders
      and orders
10 Rules for transport, storage, erection, operation
      and maintenance
Figure 1 - Fluid-filled cable connection assembly -
           Typical arrangement
Figure 2 - Fluid-filled cable connection assembly -
           Dimensions
Figure 3 - Dry type cable connection assembly -
           Typical arrangements
Figure 4 - Dry type cable connection assembly -
           Dimensions
Figure 5 - Non-symmetrical arrangement for dielectric
           tests of cable terminations

Covers the connection assembly of cables to gas-insulated metal-enclosed switchgear in single- or three-phase arrangements where the cable terminations are fluid-filled and there is a separating insulating barrier between the cable insulation and the gas insulation of the switchgear.The contents of corrigenda of February 2000 and December 2000 have been included in this copy.

DocumentType
Technical Specification
Pages
33
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
BS 6904:1987 Identical
VDE 0670-802 : DRAFT 1997 Similar to
NEN NPR IEC/TS 60859 : 1999 C1 2000 Identical

BS 7923:2004 Electric cables. Internal gas-pressure cables and accessories for alternating voltages up to and including 275 kV (<i>U</i><sub>m</sub> = 300 kV). Requirements and test methods
BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
BIS IS/IEC 62271-203 : 2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
IEEE DRAFT C37.123 : D2 FEB 96 DRAFT GUIDE TO SPECIFICATIONS FOR GAS-INSULATED ELECTRIC POWER SUBSTATION EQUIPMENT
BS 7922:2004 Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (<i>U</i><sub>m</sub> = 420 kV). Requirements and test methods
EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear

IEC 60517:1990 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 60141-1:1993 Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV

View more information
$195.99
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more