Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEEE 1815.1-2015

Current
Current

The latest, up-to-date edition.

IEEE Standard for Exchanging Information Between Networks Implementing IEC 61850 and IEEE Std 1815(TM) [Distributed Network Protocol (DNP3)]
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

16-12-2016

1. Overview
2. Normative references
4. Conceptual architecture
5. Use cases for configuring the gateway
6. Mapping of a device-oriented information
    model to DNP3
7. Mapping of data structure
8. Mapping of abstract communications service
    interface (IEC 61850-7-2:2010)
9. Describing the DNP3/IEC 61850 mapping using
    XML
10. Security Requirements
Annex A (normative) - Leaf level mapping rules and
        conformance table
Annex B (informative) - Recommended implementation
        levels
Annex C (informative) - Recommended mapping of IINs
        to IEC 61850-7-4 ed2.0 [B3]
Annex D (informative) - Time synchronization security
Annex E (informative) - Example XML files
Annex F (informative) - Mapping to NISTIR 7628 [B9]
Annex G (informative) - Bibliography

Defines the standard approach for mapping between IEEE Std 1815 [TM], IEEE Standard for Electric Power Systems Communications - Distributed Network Protocol (DNP3) and IEC 61850, Communication networks and systems for power utility automation.

Committee
Power System Communications and Cybersecurity
DocumentType
Standard
ISBN
978-1-5044-0598-0
Pages
368
PublisherName
Institute of Electrical & Electronics Engineers
Status
Current

EN 61400-25-4:2017 Wind energy generation systems - Part 25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile
CEI EN 61400-25-4 : 2009 WIND ENERGY GENERATION SYSTEMS - PART 25-4: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - MAPPING TO COMMUNICATION PROFILE
I.S. EN 61400-25-4:2017 WIND ENERGY GENERATION SYSTEMS - PART 25-4: COMMUNICATIONS FOR MONITORING AND CONTROL OF WIND POWER PLANTS - MAPPING TO COMMUNICATION PROFILE
IEEE 2030.100-2017 IEEE Recommended Practice for Implementing an IEC 61850-Based Substation Communications, Protection, Monitoring, and Control System

IEC 61850-5:2013 Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models
IEC 61850-7-2:2010 Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
IEC TS 62351-3:2007 Power systems management and associated information exchange - Data and communications security - Part 3: Communication network and system security - Profiles including TCP/IP
IEC TS 62351-6:2007 Power systems management and associated information exchange - Data and communications security - Part 6: Security for IEC 61850
IEC TS 62351-4:2007 Power systems management and associated information exchange - Data and communications security - Part 4: Profiles including MMS
IEC 61850-6:2009 Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs
ISO/IEC 8802-3:2000 Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications
IEEE 1686-2007 IEEE Standard for Substation Intelligent Electronic Devices (IEDs) Cyber Security Capabilities
IEC TS 62351-5:2013 Power systems management and associated information exchange - Data and communications security - Part 5: Security for IEC 60870-5 and derivatives
IEEE C37.238-2011 IEEE Standard Profile for Use of IEEE 1588 Precision Time Protocol in Power System Applications
IEC TR 61850-90-5:2012 Communication networks and systems for power utility automation - Part 90-5: Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118
IEC 61850-8-1:2011 Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3
IEC 61850-9-2:2011 Communication networks and systems for power utility automation - Part 9-2: Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3
IEEE 1686-2013 IEEE Standard for Intelligent Electronic Devices Cyber Security Capabilities
IEC 61850-7-4:2010 Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
IEC 61850-7-3:2010 Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes
IEEE 1815-2012 REDLINE IEEE Standard for Electric Power Systems Communications-Distributed Network Protocol (DNP3)
IEC TS 62351-8:2011 Power systems management and associated information exchange - Data and communications security - Part 8: Role-based access control

View more information
$613.91
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more