1. Overview
2. Normative references
3. Operating limitations
4. External influences on internal operating
   temperatures
5. Ventilation and condensation control
6. Enclosure color and finish considerations
7. Current-carrying capabilities of switchgear
8. Suggested modifications of standard designs
9. Conclusion
Annex A (informative) - Figures
Annex B (informative) - Tables
Annex C (informative) - Bibliography

Pertains to assist in evaluating the effect of solar radiation on outdoor metal-enclosed switchgear, and is, for example, applicable to outdoor metal-enclosed circuit breaker power switchgear, metal-clad switchgear, metal-enclosed interrupter switchgear, metal-enclosed gas insulated switchgear, control switchboards, metal-enclosed bus, and pad-mounted switchgear.

Committee
Switchgear
DocumentType
Standard
Pages
30
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

14/30257408 DC : 0 BS IEC/IEEE 62271-37-013 ED 1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 37-013: ALTERNATING-CURRENT GENERATOR CIRCUIT-BREAKERS
BS EN 62271-203:2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEEE C37.100.1-2007 IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V
IEEE C37.23-2003 IEEE Standard for Metal-Enclosed Bus
UNE-EN 62271-203:2013 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEEE C37.010-1999 IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
IEEE C37.13-2015 REDLINE IEEE Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures
CSA C22.2 No. 253 : 2016 MEDIUM-VOLTAGE AC CONTACTORS, CONTROLLERS, AND CONTROL CENTRES
NEMA SG 3 : 1995 LOW-VOLTAGE POWER CIRCUIT BREAKERS
NEMA SG 5-1995 POWER SWITCHGEAR ASSEMBLIES
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers
08/30179468 DC : DRAFT MAR 2008 BS EN 62271-203 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
IEEE C37.122.1-2014 REDLINE IEEE Guide for Gas-Insulated Substations Rated Above 52 kV
CSA C22.2 No. 273 : 2014(R2019) CABLEBUS
I.S. EN 62271-203:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV))
IEC 62271-111:2012 High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
IEEE 3001.5-2013 IEEE Recommended Practice for the Application of Power Distribution Apparatus in Industrial and Commercial Power Systems
IEEE C37.38-1989 IEEE Standard for Gas Insulated, Metal-Enclosed Disconnecting, Interrupter, and Grounding Switches
IEEE DRAFT C37.63 : D5 95 STANDARD REQUIREMENTS FOR OVERHEAD, PAD-MOUNTED, DRY-VAULT, AND SUBMERSIBLE AUTOMATIC LINE SECTIONALIZERS FOR AC SYSTEMS
IEEE/IEC C37.60-2012 IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
IEEE C37.20 : 69(R1981) SWITCH GEAR ASSEMBLIES AND METAL-ENCLOSED BUS
IEEE C37.13.1-2006 IEEE Standard for Definite Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear
IEEE C37.121-2012 GUIDE FOR SWITCHGEAR - UNIT SUBSTATION - REQUIREMENTS
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
CEI EN 62271-203 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
IEEE C37.121-2012 REDLINE IEEE Guide for Switchgear - Unit Substation - Requirements
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
IEEE C37.21-2005 IEEE Standard for Control Switchboards
IEEE C37.20.1-2015 REDLINE IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEEE C37.23-2015 IEEE Standard for Metal-Enclosed Bus
IEEE C37.63-2005 IEEE Standard Requirements for Overhead, Pad-Mounted, Dry-Vault, and Submersible Automatic Line Sectionalizers for AC Systems

IEEE C37.20.1-2015 REDLINE IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear
IEC 60068-2-5:2010 Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing
IEEE C37.100.1-2007 IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V
IEEE C37.74-2014 REDLINE IEEE Standard Requirements for Subsurface, Vault, and Padmounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems up to 38 kV
IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
IEC 60068-2-9:1975 Environmental testing - Part 2: Tests. Guidance for solar radiation testing
IEC 60721-2-4:1987+AMD1:1988 CSV Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature
IEEE C37.21-2005 IEEE Standard for Control Switchboards
IEEE C37.23-2003 IEEE Standard for Metal-Enclosed Bus

View more information
$264.00
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more