Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEEE DRAFT C37.06 : D6 2004

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES
Superseded date

06-11-2009

Published date

12-01-2013

Foreword
1 Scope
2 Referenced Standards
Explanatory comments for Tables 1, 2 and 3 (Circuit breakers
applied to network rated 100 kV or less)
Explanatory Comments to Tables 1A, 1B, 2A and 2B (and all
two-parameters rate of rise of recovery voltages as in Table 3)
Explanatory Comments to Tables 3A and 3B
Notes for Tables 1C, 2C, and 3C
Notes for Table 8
Tables
Annex A (INFORMATIVE)
ANNEX B (INFORMATIVE) GUIDE FOR HIGH-VOLTAGE CIRCUIT BREAKER
                      RATED ON A SYMMETRICAL CURRENT BASIS
                      DESIGNATED "DEFINITE PURPOSE FOR FAST
                      TRANSIENT RECOVERY VOLTAGE RISE TIMES"
Foreword to Annex B
1 - Scope
2 - Purpose
3 - References
4 - Rated Values

Applies to all indoor and outdoor types of AC high-voltage circuit breakers rated above 1000 volts and rated on a symmetrical current basis.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy

IEEE C37.100.1-2007 IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V
IEEE C37.12-2008 REDLINE IEEE Guide for Specifications of High-Voltage Circuit Breakers (over 1000 Volts)

IEEE 32-1972 IEEE Standard Requirements, Terminology, and Test Procedures for Neutral Grounding Devices
IEEE C37.09a-2005 TEST PROCEDURE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - AMENDMENT 1: CAPACITANCE CURRENT SWITCHING
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEEE C37.010-1999 IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
IEEE C37.011-2011 REDLINE IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
IEEE C37.012-2014 IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers Above 1000 V
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more