Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ISO 80601-2-74:2017

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Medical electrical equipment Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

13-07-2021

Language(s)

English, French

Published date

18-05-2017

ISO 80601-2-74:2017 applies to the basic safety and essential performance of a humidifier, also hereafter referred to as me equipment, in combination with its accessories, the combination also hereafter referred to as me system.

ISO 80601-2-74:2017 is also applicable to those accessories intended by their manufacturer to be connected to a humidifier where the characteristics of those accessories can affect the basic safety or essential performance of the humidifier.

EXAMPLE 1 Heated breathing tubes (heated-wire breathing tubes) or me equipment intended to control these heated breathing tubes (heated breathing tube controllers).

NOTE 1 Heated breathing tubes and their controllers are me equipment and are subject to the requirements of IEC 606011.

NOTE 2 ISO 5367 specifies other safety and performance requirements for breathing tubes.

ISO 80601-2-74:2017 includes requirements for the different medical uses of humidification, such as invasive ventilation, non-invasive ventilation, nasal high-flow therapy, and obstructive sleep apnoea therapy, as well as humidification therapy for tracheostomy patients.

NOTE 3 A humidifier can be integrated into other equipment. When this is the case, the requirements of the other equipment also apply to the humidifier.

EXAMPLE 2 Heated humidifier incorporated into a critical care ventilator where ISO 806012-12[12] also applies.

EXAMPLE 3 Heated humidifier incorporated into a homecare ventilator for dependent patients where ISO 806012-72[14] also applies.

EXAMPLE 4 Heated humidifier incorporated into sleep apnoea therapy equipment where ISO 806012-70[13] also applies.

ISO 80601-2-74:2017 also includes requirements for an active hme (heat and moisture exchanger), me equipment which actively adds heat and moisture to increase the humidity level of the gas delivered from the hme to the patient. This document is not applicable to a passive hme, which returns a portion of the expired moisture and heat of the patient to the respiratory tract during inspiration without adding heat or moisture.

NOTE 4 ISO 93601[5] and ISO 93602[6] specify the safety and performance requirements for a passive hme.

If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as relevant.

Hazards inherent in the intended physiological function of me equipment or me systems within the scope of this document are not covered by specific requirements in this document except in IEC 606011:2005+AMD1:2012, 7.2.13 and 8.4.1.

NOTE 5 Additional information can be found in IEC 606011:2005+AMD1:2012, 4.2.

ISO 80601-2-74:2017 does not specify the requirements for cold pass-over or cold bubble-through humidification devices, the requirements for which are given in ISO 20789:?.[8]

This document is not applicable to equipment commonly referred to as "room humidifiers" or humidifiers used in heating, ventilation and air conditioning systems, or humidifiers incorporated into infant incubators.

ISO 80601-2-74:2017 is not applicable to nebulizers used for the delivery of drugs to patients.

NOTE 6 ISO 27427[10] specifies the safety and performance requirements for nebulizers.

ISO 80601-2-74:2017 is a particular standard in the IEC 606011 and the ISO/IEC 80601 series.

DevelopmentNote
Supersedes ISO/DIS 80601-2-74 & ISO 8185. (05/2017)
DocumentType
Standard
Pages
88
ProductNote
THIS STANDARD ALSO REFERS TO ISO 80369-2
PublisherName
International Organization for Standardization
Status
Superseded
SupersededBy

17/30346437 DC : 0 BS ISO 18250-7 - CONNECTORS FOR RESERVOIR DELIVERY SYSTEMS FOR HEALTHCARE APPLICATIONS - PART 7: CONNECTORS FOR INTRAVASCULAR INFUSION
17/30338753 DC : 0 BS ISO 80601-2-79 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-79: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF VENTILATORY SUPPORT EQUIPMENT FOR VENTILATORY IMPAIRMENT
17/30338756 DC : 0 BS ISO 80601-2-80 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-80: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF VENTILATORY SUPPORT EQUIPMENT FOR VENTILATORY INSUFFICIENCY

IEC 60601-2-19:2009+AMD1:2016 CSV Medical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
ISO 3744:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane
IEC 60601-1:1988/AMD1:1991 Amendment 1 - Medical electrical equipment - Part 1: General requirements for safety
EN 15986:2011 Symbol for use in the labelling of medical devices - Requirements for labelling of medical devices containing phthalates
ISO 18562-1:2017 Biocompatibility evaluation of breathing gas pathways in healthcare applications — Part 1: Evaluation and testing within a risk management process
IEC 60601-1-6:2010+AMD1:2013 CSV Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
ISO 5356-1:2015 Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets
ISO 16142-1:2016 Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO 80601-2-70:2015 Medical electrical equipment Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment
IEC 60601-1-8:2006+AMD1:2012 CSV Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems
IEC 62366-1:2015 Medical devices - Part 1: Application of usability engineering to medical devices
ISO 5367:2014 Anaesthetic and respiratory equipment — Breathing sets and connectors
ISO 80601-2-12:2011 Medical electrical equipment Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
ISO 8185:2007 Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems
ISO 80601-2-72:2015 Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients
IEC 62304:2006+AMD1:2015 CSV Medical device software - Software life cycle processes
ISO 23328-2:2002 Breathing system filters for anaesthetic and respiratory use — Part 2: Non-filtration aspects
IEC TR 60878:2015 Graphical symbols for electrical equipment in medical practice
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
ISO 80369-1:2010 Small-bore connectors for liquids and gases in healthcare applications Part 1: General requirements
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
ISO 9360-1:2000 Anaesthetic and respiratory equipment — Heat and moisture exchangers (HMEs) for humidifying respired gases in humans — Part 1: HMEs for use with minimum tidal volumes of 250 ml
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
ISO 4135:2001 Anaesthetic and respiratory equipment Vocabulary
ISO 9360-2:2001 Anaesthetic and respiratory equipment — Heat and moisture exchangers (HMEs) for humidifying respired gases in humans — Part 2: HMEs for use with tracheostomized patients having minimum tidal volumes of 250 ml
ISO 15223-1:2016 Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements
ISO 17664:2017 Processing of health care products Information to be provided by the medical device manufacturer for the processing of medical devices
ISO 27427:2013 Anaesthetic and respiratory equipment — Nebulizing systems and components
IEC 62366:2007/AMD1:2014 Amendment 1 - Medical devices - Application of usability engineering to medical devices
ISO 7396-1:2016 Medical gas pipeline systems — Part 1: Pipeline systems for compressed medical gases and vacuum

View more information
$118.72
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more