ISO 9869-1:2014

Current
Current

The latest, up-to-date edition.

Thermal insulation Building elements In-situ measurement of thermal resistance and thermal transmittance Part 1: Heat flow meter method
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

29-07-2014

ISO 9869-1:2014 describes the heat flow meter method for the measurement of the thermal transmission properties of plane building components, primarily consisting of opaque layers perpendicular to the heat flow and having no significant lateral heat flow.

The properties which can be measured are:

a) the thermal resistance, R, and thermal conductance, , from surface to surface;

b) the total thermal resistance, RT, and transmittance from environment to environment, U, if the environmental temperatures of both environments are well defined.

The heat flow meter measurement method is also suitable for components consisting of quasi homogeneous layers perpendicular to the heat flow, provided that the dimensions of any inhomogeneity in close proximity to the heat flow meter (HFM) is much smaller than its lateral dimensions and are not thermal bridges which can be detected by infrared thermography.

ISO 9869-1:2014 describes the apparatus to be used, the calibration procedure for the apparatus, the installation and the measurement procedures, the analysis of the data, including the correction of systematic errors and the reporting format.

DevelopmentNote
Supersedes ISO/DIS 9869-1 and ISO 9869. (08/2014)
DocumentType
Standard
Pages
36
PublisherName
International Organization for Standardization
Status
Current
Supersedes

Standards Relationship
NEN ISO 9869-1 : 2014 Identical
UNI ISO 9869-1 : 2015 Identical
BS ISO 9869-1:2014 Identical

17/30319129 DC : DRAFT APR 2017 BS ISO 9869-2 - THERMAL INSULATION - BUILDING ELEMENTS - IN-SITU MEASUREMENT OF THERMAL RESISTANCE AND THERMAL TRANSMITTANCE - PART 2: INFRARED METHOD FOR FRAME STRUCTURE DWELLING
ASTM C 1130 : 2017 : REDLINE Standard Practice for Calibration of Thin Heat Flux Transducers

ISO 8302:1991 Thermal insulation — Determination of steady-state thermal resistance and related properties — Guarded hot plate apparatus
ISO 8301:1991 Thermal insulation Determination of steady-state thermal resistance and related properties Heat flow meter apparatus
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
ISO 8990:1994 Thermal insulation — Determination of steady-state thermal transmission properties — Calibrated and guarded hot box
ISO 6781:1983 Thermal insulation — Qualitative detection of thermal irregularities in building envelopes — Infrared method
ISO 7345:1987 Thermal insulation Physical quantities and definitions

View more information
$326.02
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more