MIL-STD-188-125-1 Base Document:1998

Current
Current

The latest, up-to-date edition.

HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND-BASED C[4]1 FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS PART 1 FIXED FACILITIES
Available format(s)

PDF

Language(s)

English

FOREWORD
1 SCOPE
      1.1 Purpose
      1.2 Scope
      1.3 Applications
      1.4 Objectives
2 APPLICABLE DOCUMENTS
      2.1 General
      2.2 Government documents
             2.2.1 Specifications, standards, and
                      handbooks
             2.2.2 Other Government documents, drawings,
                      and publications
      2.3 Non-Government publications
      2.4 Order of precedence
3 DEFINITIONS
      3.1 Acronyms used in this standard
      3.2 Sources for definitions
      3.3 Definitions
             3.3.1 Aperture point-of-entry (POE)
             3.3.2 Conductive POE
             3.3.3 Continuous wave (CW) immersion
             3.3.4 Corrective maintenance
             3.3.5 Electromagnetic barrier
             3.3.6 Electromagnetic closure
             3.3.7 Electromagnetic stress (HM/HS)
             3.3.8 Facility HEMP shield
             3.3.9 HEMP acceptance test
             3.3.10 HEMP hardness
             3.3.11 HEMP hardness assurance
             3.3.12 HEMP hardness configuration baseline
             3.3.13 HEMP hardness critical item (HCI)
             3.3.14 HEMP hardness critical process (HCP)
             3.3.15 HEMP hardness maintenance (HM)
             3.3.16 HEMP hardness maintenance and hardness
                      surveillance (HM/HS)
             3.3.17 HEMP protection subsystem
             3.3.18 HEMP hardness surveillance (HS)
             3.3.19 HEMP hardness surveillance/
                      reverification testing
             3.3.20 Low-risk HEMP hardening
             3.3.21 Main barrier electrical POE protective
                      device
             3.3.22 Mission-critical systems (MCS)
             3.3.23 Norton equivalent circuit or Norton
                      source
             3.3.24 Penetrating conductor
             3.3.25 Penetration entry area
             3.3.26 Performance degradation
             3.3.27 Point-of-entry (POE)
             3.3.28 POE protective device or POE treatment
             3.3.29 Preventive maintenance
             3.3.30 Primary special electrical POE
                      protective device
             3.3.31 Protected volume
             3.3.32 Pulsed current injection (PCI)
             3.3.33 Residual internal stress
             3.3.34 Retrofit HEMP hardening
             3.3.35 Secondary special electrical POE
                      protective device
             3.3.36 Shielded enclosure leak detection system
                      (SELDS)
             3.3.37 Special protective measures
             3.3.38 Special protective volume
             3.3.39 Verification testing
             3.3.40 Vulnerability threshold (of an equipment)
             3.3.41 Waveguide below cutoff (WBC)
             3.3.42 Waveguide-below-cutoff array
4 GENERAL REQUIREMENTS
       4.1 General
              4.1.1 HEMP protection overview
              4.1.2 Integration with related requirements
       4.2 Hardness program overview
       4.3 HEMP hardening design
              4.3.1 Facility shield
              4.3.2 POEs
              4.3.3 MCS
              4.3.4 Special protective measures
       4.4 HEMP testing
              4.4.1 Quality assurance program
              4.4.2 Acceptance testing
              4.4.3 Verification testing
       4.5 HM/HS
              4.5.1 HM/HS program development
              4.5.2 HM/HS program implementation
5 DETAILED REQUIREMENTS
       5.1 HEMP protection subsystem topology
              5.1.1 Electromagnetic barrier topology
              5.1.2 Penetration entry area
       5.2 Penetration entry area
              5.2.1 Equipotential ground plane
              5.2.2 Grounding to the facility HEMP shield
       5.3 Facility HEMP shield
              5.3.1 Shielding effectiveness
              5.3.2 Shield configuration
              5.3.3 Shield monitoring capability
              5.3.4 Shield construction quality assurance
       5.4 Architectural POEs
              5.4.1 HEMP protection for architectural POEs
              5.4.2 Personnel entryways and exits
              5.4.3 Equipment accesses
              5.4.4 Acceptance testing for architectural
                       POE protective devices
       5.5 Mechanical POEs
              5.5.1 HEMP protection for mechanical POEs
              5.5.2 Piping POEs
              5.5.3 Ventilation POEs
              5.5.4 Acceptance testing for mechanical POE
                       protective devices
       5.6 Structural POEs
              5.6.1 HEMP protection for structural POEs
              5.6.2 Acceptance testing for structural POE
                       protective treatments
       5.7 Electrical POEs
              5.7.1 HEMP protection for electrical POEs
              5.7.2 Commercial electric power feeder POEs
              5.7.3 Other electrical power feeder POEs
              5.7.4 Audio and data line POEs
              5.7.5 Electrical control and signal line POEs
              5.7.6 RF communications antenna line POEs
              5.7.7 Conduit shielding
              5.7.8 Acceptance testing of main barrier
                       electrical POE protective devices
       5.8 Special protective measures
              5.8.1 MCS outside the main electromagnetic
                       barrier
              5.8.2 MCS inside the main electromagnetic
                       barrier
              5.8.3 Special protective volumes
              5.8.4 Acceptance testing of special
                       protective measures
       5.9 Reliability and maintainability
       5.10 Safety and human engineering
       5.11 Testability
       5.12 Corrosion control
       5.13 Configuration management
       5.14 Verification testing
              5.14.1 CW immersion testing
              5.14.2 PCI verification testing
              5.14.3 Verification for special protective
                      measures
       5.15 HM/HS program requirements
              5.15.1 HS/reverification test procedures
              5.15.2 Maintenance and inspection procedures
              5.15.3 Supply support requirements
              5.15.4 Training requirements
              5.15.5 Technical data
              5.15.6 Delivery
              5.15.7 Implementation
6 NOTES
       6.1 Intended use
       6.2 Issues of DoDISS
       6.3 Subject term (key word) listing
       6.4 Changes from previous issue
Figure 1 - Minimum HEMP shielding effectiveness requirements
           (measured IAW procedures of Appendix A)
Figure 2 - Typical waveguide and vestibule entryways
Figure 3 - Typical waveguide-below-cutoff POE protective
           devices
Figure 4 - Typical waveguide-below-cutoff array ventilation
           POE protective device
Figure 5 - Typical electrical POE protective device
Figure 6 - Typical special protective volumes
Table I - Injected pulse characteristics and residual internal
          stress limits for classes of electrical POEs
Table II - Maximum conduit length as a function of conduit
           outside diameter (OD)
APPENDIX A - SHIELDING EFFECTIVENESS (SE) TEST PROCEDURES
APPENDIX B - PULSED CURRENT INJECTION (PCI) TEST PROCEDURES
APPENDIX C - CONTINUOUS WAVE (CW) IMMERSION TEST PROCEDURES
CONCLUDING MATERIAL

Gives the minimum performance requirements for low-risk protection form mission-aborting damage or upset due to HEMP threat environments given in MIL-STD-2169. Also gives the minimum testing requirements for demonstrating that prescribed performance has been achieved and for verifying that the installed protection subsystem provides the operationally required hardness for the completed facility.

Committee
AREA TCSS
DevelopmentNote
Supersedes MIL STD 188 125 (A). (08/2000) NOTICE 1 - Notice of Validation. (04/2005)
DocumentType
Standard
Pages
107
PublisherName
US Military Specs/Standards/Handbooks
Status
Current
Supersedes

UFC 3-501-01 : 2015 UNIFIED FACILITIES CRITERIA - ELECTRICAL ENGINEERING
FC 4-218-01F : 2015 FACILITIES CRITERIA - AIR FORCE CRITERIA FOR PRECISION MEASUREMENT EQUIPMENT LABORATORY DESIGN AND CONSTRUCTION
MIL STD 11991 : A GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES
IEC TS 61000-5-8:2009 Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure
PD IEC/TS 61000-5-10:2017 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI
MIL-STD-461 Revision G:2015 REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
IEEE/ANSI C63.14-2014 REDLINE American National Standard Dictionary of Electromagnetic Compatibility (EMC) including Electromagnetic Environmental Effects (E3)
IEC 61000-4-24:2015 Electromagnetic compatibility (EMC) - Part 4-24: Testing and measurement techniques - Test methods for protective devices for HEMP conducted disturbance
MIL-STD-464 Revision C:2010 ELECTROMAGNETIC ENVIRONMENTAL EFFECTS REQUIREMENTS FOR SYSTEMS
IEC TS 61000-5-10:2017 Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI
PD IEC/TR 61000-1-5:2004 Electromagnetic compatibility (EMC) General - High power electromagnetic (HPEM) effects on civil systems
DD IEC/TS 61000-5-8:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. HEMP protection methods for the distributed infrastructure
IEC TR 61000-1-5:2004 Electromagnetic compatibility (EMC) - Part 1-5: General - High power electromagnetic (HPEM) effects on civil systems
13/30285924 DC : 0 BS EN 61000-4-24 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-24: TESTING AND MEASUREMENT TECHNIQUES - TEST METHODS FOR PROTECTIVE DEVICES FOR HEMP CONDUCTED DISTURBANCE
MIL-STD-188-125-2 Base Document:1999 HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND-BASED C[4]I FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS - PART 2 - TRANSPORTABLE SYSTEMS
AEP-41 VOL 6 : 2014 NATO IMPLEMENTATION OF UNIFIED PROTECTION AGAINST ELECTROMAGNETIC ENVIRONMENTAL EFFECTS (UE[3])

NFPA 101 : 2018 LIFE SAFETY CODE
FED-STD-1037 Revision C:1996 TELECOMMUNICATIONS: GLOSSARY OF TELECOMMUNICATION TERMS
IEEE/ANSI C63.14-2014 REDLINE American National Standard Dictionary of Electromagnetic Compatibility (EMC) including Electromagnetic Environmental Effects (E3)
MIL-HDBK-423 Base Document:1993 HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR FIXED AND TRANSPORTABLE GROUND - BASED C4 1 FACILITIES - VOLUME 1 - FIXED FACILITIES
MIL-STD-100 Revision G:1997 ENGINEERING DRAWINGS
MIL-HDBK-419 Revision A:1987 GROUNDING, BONDING, AND SHIELDING FOR ELECTRONIC EQUIPMENTS AND FACILITIES - VOLUME 1: BASIC THEORY & VOLUME 2: APPLICATIONS

View more information
$32.74
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more