Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NF EN 62271-209 : 2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY TYPE CABLE-TERMINATIONS

Superseded date

04-02-2023

Published date

12-01-2013

AVANT-PROPOS
1 Domaine d'application
2 Références normatives
3 Termes et définitions
4 Limites de fourniture
   4.1 Généralités
   4.2 Protection contre la surtension
5 Caractéristiques assignées
   5.1 Généralités
   5.2 Tension assignée
   5.3 Niveau d'isolement assigné
   5.4 Courant assigné en service continu et échauffement
   5.5 Courant de courte durée admissible assigné, valeur
       crête du courant admissible assigné et durée
       de court-circuit assignée
   5.6 Pression assignée de remplissage du gaz isolant dans
       l'enveloppe du raccordement de câble
6 Exigences pour la conception et la construction
   6.1 Exigences pour la tenue à la pression
   6.2 Efforts mécaniques sur les extrémités de câble
Figure 1 - Pression de service du gaz isolant dans
           l'enveloppe du raccordement de câble
7 Dimensions normalisées
   7.1 Extrémité de câble remplie d'un fluide
   7.2 Extrémité de câble sèche
   7.3 Enveloppe de l'extrémité de câble tripolaire
8 Essais
   8.1 Généralités
   8.2 Essais diélectriques de type des extrémités de câble
       8.2.1 Généralités
       8.2.2 Essai diélectrique de type des extrémités de câble
             dans une enveloppe unipolaire
       8.2.3 Essai diélectrique de type des extrémités de câble
             dans une enveloppe tripolaire
   8.3 Essais après pose du système de câble
9 Renseignements à donner dans les appels d'offres, les
   soumissions et les commandes
10 Règles pour le transport, le stockage, l'installation, la
   conduite et la maintenance
Figure 2 - Assemblage de raccordement de câble rempli
           d'un fluide - Exemple de disposition
Figure 3 - Assemblage de raccordement de câble rempli
           d'un fluide - Dimensions
Figure 4 - Assemblage de raccordement de câble
           sec - Exemples des dispositions
Figure 5 - Assemblage de raccordement de câble
           sec - Dimensions
Annexe ZA (normative) Références normatives à d'autres
          publications internationales avec les publications
          européennes correspondantes
Annexe ZB (informative) Divergences A

Defines the connection assembly of fluid-filled and extruded cables to gas-insulated metal enclosed switchgear (GIS), in single- or three-phase arrangements where the cable-terminations are fluid-filled or dry type and there is a separating insulating barrier between the cable insulation and the gas insulation of the switchgear.

DevelopmentNote
Indice de classement: C64-471-209. PR NF EN 62271-209 June 2006. (06/2006)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
IEC 62271-209:2007 Identical
EN 62271-209:2007 Identical
I.S. EN 62271-209:2007 Identical
BS EN 62271-209:2007 Identical

NF EN 62271-205 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
NFC 33 254 : 2016 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - PARTICULAR REQUIREMENTS FOR THE USE ON FRENCH POWER SYSTEMS OF CABLES WITH EXTRUDED INSULATION AND OF THEIR ACCESSORIES OF RATED VOLTAGE ABOVE 30 KV (U[M] = 36 KV)

IEC 60038:2009 IEC standard voltages
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
HD 472 S1:1989/AC:2013 NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
NF EN 60694 : 96 AMD 2 2002 COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 60141-1:1993 Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV
NF EN 62271-203 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more