NF EN ISO 15877-2 : 2009 AMD 1 2011

Current
Current

The latest, up-to-date edition.

PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 2: PIPES
Published date

12-01-2013

Avant-propos
Introduction
1 Domaine d'application
2 Références normatives
3 Termes et définitions, symboles et abréviations
4 Matière
   4.1 Généralités
   4.2 Matière des tubes
   4.3 Évaluation des valeurs sigma[LCL]
   4.4 Influence sur l'eau destinée à la consommation
        humaine
5 Caractéristiques générales
   5.1 Aspect
   5.2 Chanfreinage
   5.3 Opacité
6 Caractéristiques géométriques
   6.1 Généralités
   6.2 Dimensions des tubes
        6.2.1 Diamètres extérieurs
        6.2.2 Épaisseurs de paroi et tolérances
        6.2.3 Longueur des tubes
        6.2.4 Tubes à emboîtures
7 Caractéristiques mécaniques
   7.1 Résistance à la pression interne
   7.2 Résistance au choc
   7.3 Résistance à la traction
8 Caractéristiques physiques
9 Exigences d'aptitude à l'emploi
10 Colles
11 Marquage
   11.1 Généralités
   11.2 Marquage minimal exigé
   11.3 Marquage supplémentaire
Annexe A (informative) Détermination de la valeur maximale
                       calculée de la série du tube S[calc,max]
   A.1 Généralités
   A.2 Contrainte de dimensionnement
   A.3 Détermination de la valeur maximale de S[calc]
        (S[calc,max])
   A.4 Utilisation de S[calc], max dans la détermination de
        l'épaisseur de paroi
Bibliographie

Specifies the requirements of pipes made from chlorinated poly(vinyl chloride) (PVC-C) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems), under design pressures and temperatures appropriate to the class of application.

DevelopmentNote
Indice de classement: T54-014-2. PR NF EN ISO 15877-2 September 2006. (09/2006) Supersedes NFT 54 014-2. (01/2011)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current
Supersedes

NF EN ISO 21003-2 : 2008 AMD 1 2011 MULTILAYER PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS INSIDE BUILDINGS - PART 2: PIPES
NF EN ISO 21003-1 : 2008 MULTILAYER PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS INSIDE BUILDINGS - PART 1: GENERAL
NF EN ISO 15877-3 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 3: FITTINGS
NF EN ISO/TS 15877-7 : 2004 XP PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 7: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY
NF EN ISO 15877-5 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM

NF EN ISO 15877-3 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 3: FITTINGS
ISO 6259-2:1997 Thermoplastics pipes Determination of tensile properties Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly (vinyl chloride) (PVC-C) and high-impact poly (vinyl chloride) (PVC-HI)
NF EN ISO 7686 : 2005 PLASTICS PIPES AND FITTINGS - DETERMINATION OF OPACITY
NF EN ISO 2505 : 2005 THERMOPLASTICS PIPES - LONGITUDINAL REVERSION - TEST METHOD AND PARAMETERS
NF EN 744 : 1995 PLASTICS PIPING AND DUCTING SYSTEMS - THERMOPLASTICS PIPES - TEST METHOD FOR RESISTANCE TO EXTERNAL BLOWS BY THE ROUND-THE-CLOCK METHOD
NF EN ISO 15877-1 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 1: GENERAL
NF EN ISO 6259-1 : 2015 THERMOPLASTICS PIPES - DETERMINATION OF TENSILE PROPERTIES - PART 1: GENERAL TEST METHOD
NF EN ISO 3126 : 2005 PLASTICS PIPING SYSTEMS - PLASTICS COMPONENTS - MEASUREMENT OF DIMENSIONS
NF EN ISO 1167-1 : 2006 THERMOPLASTICS PIPES, FITTINGS AND ASSEMBLIES FOR THE CONVEYANCE OF FLUIDS - DETERMINATION OF RESISTANCE TO INTERNAL PRESSURE - PART 1: GENERAL METHOD
NF EN ISO 9080 : 2012 PLASTICS PIPING AND DUCTING SYSTEMS - DETERMINATION OF THE LONG-TERM HYDROSTATIC STRENGTH OF THERMOPLASTICS MATERIALS IN PIPE FORM BY EXTRAPOLATION
NF EN ISO 1167-2 : 2006 THERMOPLASTICS PIPES, FITTINGS AND ASSEMBLIES FOR THE CONVEYANCE OF FLUIDS - DETERMINATION OF THE RESISTANCE TO INTERNAL PRESSURE - PART 2: PREPARATION OF PIPE TEST PIECES
NF EN 727 : 1994 PLASTICS PIPING AND DUCTING SYSTEMS - THERMOPLASTICS PIPES AND FITTINGS - DETERMINATION OF VICAT SOFTENING TEMPERATURE (VST)
NF EN ISO 15877-5 : 2009 AMD 1 2011 PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - CHLORINATED POLY(VINYL CHLORIDE) (PVC-C) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more