Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NFC 32 201-14 : 2003

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 14: FLEXIBLE CABLES (CORDS), INSULATED AND SHEATHED WITH HALOGEN-FREE THERMOPLASTIC COMPOUNDS
Superseded date

01-12-2014

Published date

12-01-2013

1 Domaine d'application
2 Références normatives
3 Câbles souples isolés et gainés de tension assignée 300/300 V
  3.1 Désignation
  3.2 Tension assignée
  3.3 Constitution
  3.4 Essais
  3.5 Guide d'emploi (informatif)
4 Câbles souples isolés et gainés de tension assignée 300/500 V
  4.1 Désignation
  4.2 Tension assignée
  4.3 Constitution
  4.4 Essais
  4.5 Guide d'emploi (informatif)
Annexe A (normative) - Prescriptions relatives aux essais
                         non-électriques de l'enveloppe isolante
                         thermoplastique TI 6
Annexe B (normative) - Prescriptions relatives aux essais
                         non-électriques de la gaine thermoplastique
                         TM 7
Annexe C (normative) - Prescriptions pour les halogènes
Annexe D (normative) - Détermination des halogènes - Essai
                         qualitatif
Annexe E (informative) - Proposition d'amendement au HD 516 S2
Annexe F (normative) - Essai d'immersion dans l'eau de la gaine

La présente Partie 14 précise les spécifications particulières des câbles souples, de tension assignée jusqu'à et y compris 300/1500 V ayant une enveloppe isolante et une gaine avec des matériaux thermoplastiques sans halogène, câbles ayant un faible dégagement de fumée et de gaz corrosifs lors d'un incendie. Ces câbles sont destinés pour connecter les appareils domestiques à l'alimentation fixe. Tous les câbles doivent répondre aux prescriptions appropriées indiquées dans la Partie 1 du HD 21 et aux prescriptions particulières le concernant figurant dans la présente Partie 14. NOTE 1: Les dimensions extérieures des câbles dans cette partie du HD 21 ont été calculées conformément à la norme EN 60719. NOTE 2: Le faible dégagement de fumée est vérifié selon la EN 50268-2. Le faible dégagement de gaz corrosifs est vérifié et fait partie intégrante de la vérification de l'absence d'halogènes (voir Annexe C).

DevelopmentNote
Indice de Classement: C32-201-14 PR NFC 32 201-14 May 2002 (06/2002)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
HD 21.14 : 2003 Identical

NF EN 60719 : 1994 CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
IEC 60228:2004 Conductors of insulated cables
IEC 60684-2:2011 Flexible insulating sleeving - Part 2: Methods of test
NFC 32 201 : 1987 INSULATED CONDUCTORS AND CABLES FOR INSTALLATIONS - POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - HARMONIZATION SERIES
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
IEC 60719:1992 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
NFC 32 074 : 1993 TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES - DETERMINATION OF DEGREE OF ACIDITY OF GASES EVOLVED DURING THE COMBUSTION OF MATERIALS TAKEN FROM ELECTRIC CABLES BY MEASURING PH AND CONDUCTIVITY
NF EN 60684-2 : 2012 FLEXIBLE INSULATING SLEEVING - PART 2: METHODS OF TEST
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
NFC 32 073-2 : 1993 MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS - TEST PROCEDURE AND REQUIREMENTS
NFC 32 102 : 1984 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - EXTRUDED SOLID DIELECTRIC INSULATED CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more