Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NFC 33 065 : 2001 XP

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SELF SUPPORTING OUTDOOR POLYMERIC TERMINATIONS OF TERMINATIONS WITH A COMPOSITE HOUSING, WITHOUT PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 150 KV (UM = 170 KV) UP TO 500 KV (UM = 550 KV)
Superseded date

01-08-2008

Published date

12-01-2013

1 Généralités
2 Capacité de transport
3 Constitution des extrémités
4 Caractéristiques des constituants
5 Installation sur le site
6 Essais de type
7 Essais après pose
8 Procédure d'acceptation de type
9 Extension de l'acceptation de type en fonction
   de la section
10 Extension de l'acceptation de type en fonction
   de la tension
Annexe A (normative) Règles de dimensionnement des
                       extrémites synthétiques et
                       prescriptions relatives aux
                       isolateurs
Annexe B (normative) Tenue au cheminement des matériaux
                       utilisés pour les extrémités de
                       type extérieur
Annexe C (normative) Essai de vieillissement accéléré
                       sous conditions climatiques simulées
Annexe D (informative) Conditions particulières au réseau
                       électrique français
Annexe E (informative) Calcul du courant de court-circuit
                       en tenant compte des effets de
                       l'asymétrie supposée maximale
Tableau 1 - Salinité et ligne de fuite nominale
              spécifique minimale
Tableau 2 - Effort maximal horizontal
Tableau 3 - Essais diélectriques sur câble et
              accessoires (exemples)
Tableau 4 - Températures maximales de l'âme
Tableau 5 - Essais d'isolement de l'écran ou de les
              pour l'extension de l'acceptation de type
Tableau 6 - Groupes de tensions assignées maximales
              pour l'extension de l'acceptation de type
Tableau A.1 - Hauteur des isolateurs
Tableau D.1 - Contraintes de court-circuit du réseau
Tableau D.2 - Dimensions de l'embase

DevelopmentNote
Indice de Classement: C33-065XP. PR NFC 33 065 October 2000. XP NFC 33 065 February 2001. (10/2002)
DocumentType
Miscellaneous Product
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

NFC 33 253 : 2006 INSULATED CABLES FOR POWER SYSTEMS - SINGLE-CORE CABLES WITH POLYMERIC INSULATION FOR RATED VOLTAGES ABOVE 150 KV (UM = 170 KV) UP TO 500 KV (UM = 525 KV)
NF EN 60071-1 : 2006 AMD 1 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
XP C20 540 : 2002 XP ENVIRONMENTAL TESTING - TEST METHODS - CLIMATIC AGEING TEST OF EQUIPMENT AND SYNTHETIC MATERIALS FOR OUTDOOR USE
NFC 63 061 : 1973 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONNECTION JOINTS FOR CONDUCTORS ONE AT LEAST OF THEM BEING AN INSULATED ALUMINIUM OR ALUMINIUM ALLOY CONDUCTOR - ELECTRICAL TEST REQUIREMENTS
IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
NF EN 60068 2-11 : 1999 ENVIRONMENTAL TESTING - PART 2: TESTS - TEST KA: SALT MIST
NFC 33 062 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SF6 INSULATED METAL ENCLOSED TERMINATIONS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
IEC 60230:1966 Impulse tests on cables and their accessories
UTEC 32 024 : 1991 INSULATED CABLES AND FLEXIBLES CORDS FOR INSTALLATIONS - GUIDE FOR THE DETERMINATION OF MECHANICAL PROPERTIES FOR INSULATING AND SHEATHING MATERIALS
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
NFC 27 601 : 1978 SPECIFICATION AND ACCEPTANCE OF NEW SULFUR HEXAFLUORIDE
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
NF EN 60811 1-1 : 96 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 1: MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 62067 : 2.0EN+(REDLINE+VERSION) POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 150 KV (U[M] = 170 KV) UP TO 500 KV (U[M] = 550 KV) - TEST METHODS AND REQUIREMENTS
NF EN 60507 : 2014 ARTIFICIAL POLLUTION TESTS ON HIGH-VOLTAGE CERAMIC AND GLASS INSULATORS TO BE USED ON A.C. SYSTEMS
NFC 66 081 : 1978 INSULATORS FOR SUB-STATIONS - HOLLOW INSULATORS SUPPLIED WITHOUT METAL FITTINGS - TESTS
IEC 60885-2:1987 Electrical test methods for electric cables. Part 2: Partial discharge tests

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more